Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
JACC Asia ; 4(4): 292-302, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38660112

ABSTRACT

Background: Sex-related disparities in clinical outcomes following transcatheter aortic valve replacement (TAVR) and the impact of sex on clinical outcomes after TAVR among different racial groups are undetermined. Objectives: This study assessed whether sex-specific differences in baseline clinical and anatomical characteristics affect clinical outcomes after TAVR and investigated the impact of sex on clinical outcomes among different racial groups. Methods: The TP-TAVR (Trans-Pacific TAVR) registry is a multinational cohort study of patients with severe aortic stenosis who underwent TAVR at 2 major centers in the United States and 1 major center in South Korea. The primary outcome was a composite of death from any cause, stroke, or rehospitalization after 1 year. Results: The incidence of the primary composite outcome was not significantly different between sexes (27.9% in men vs 28% in women; adjusted HR: 0.97; 95% CI: 0.79-1.20). This pattern was consistent in Asian (23.5% vs 23.3%; adjusted HR: 0.99; 95% CI: 0.69-1.41) and non-Asian (30.8% vs 31.6%; adjusted HR: 0.95; 95% CI: 0.72-1.24) cohorts, without a significant interaction between sex and racial group (P for interaction = 0.74). The adjusted risk for all-cause mortality was similar between sexes, regardless of racial group. However, the adjusted risk of stroke was significantly lower in male patients than in female patients, which was more prominent in the non-Asian cohort. Conclusions: Despite significantly different baseline and procedural characteristics, there were no sex-specific differences in the adjusted 1-year rates of primary composite outcomes and all-cause mortality, regardless of different racial groups. (Transpacific TAVR registry [TP-TAVR]; NCT03826264).

2.
Clin Case Rep ; 11(11): e8052, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37927980

ABSTRACT

We present a case of a quadriplegic male who developed ventricular fibrillation associated with an anomalous aortic origin of the right coronary artery. Successful revascularization was achieved with percutaneous coronary intervention. This case highlights the application of an unconventional approach to resolve ischemia in a patient with prohibitive surgical risk.

3.
JACC Asia ; 3(3): 376-387, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37323869

ABSTRACT

Background: Interracial differences in the distribution and prognostic value of conventional Society of Thoracic Surgeons (STS) score on long-term mortality after transcatheter aortic valve replacement (TAVR) are uncertain. Objectives: This study aims to compare the impact of STS scores on clinical outcomes at 1-year after TAVR between Asian and non-Asian populations. Methods: We used the Trans-Pacific TAVR (TP-TAVR) registry, a multinational multicenter, observational registry involving patients undergoing TAVR at 2 major centers in the United States and 1 major center in Korea. Patients were classified into 3 groups (low, intermediate, and high-risk) according to the STS score and compared between STS risk groups and race. The primary outcome was all-cause mortality at 1-year. Results: Among 1,412 patients, 581 were Asian and 831 were non-Asian. The distribution of the STS risk score group was different between Asian and non-Asian groups (62.5% low-, 29.8% intermediate-, and 7.7% high-risk in Asian vs 40.6% low-, 39.1% intermediate-, and 20.3% high-risk in non-Asian). In the Asian population, the all-cause mortality at 1-year was substantially higher in the high-risk STS group than in the low- and intermediate-risk groups (3.6% low-risk, 8.7% intermediate-risk, and 24.4% high-risk; log-rank P < 0.001), which was primarily driven by noncardiac mortality. In the non-Asian group, there was a proportional increase in all-cause mortality at 1-year according to the STS risk category (5.3% low-risk, 12.6% intermediate-risk, and 17.8% high-risk; log-rank P < 0.001). Conclusions: In this multiracial registry of patients with severe aortic stenosis who underwent TAVR, we identified a differential proportion and prognostic impact of STS score on 1-year mortality between Asian and non-Asian patients (TP-TAVR [Transpacific TAVR Registry]; NCT03826264).

6.
Eur Heart J Case Rep ; 4(FI1): 1-6, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33089039

ABSTRACT

BACKGROUND: Novel coronavirus-19 disease (COVID-19) is associated with significant cardiovascular morbidity and mortality. To date, there have not been reports of sinus node dysfunction (SND) associated with COVID-19. This case series describes clinical characteristics, potential mechanisms, and short-term outcomes of COVID-19 patients who experience de novo SND. CASE SUMMARY: We present two cases of new-onset SND in patients recently diagnosed with COVID-19. Patient 1 is a 70-year-old female with no major past medical history who was intubated for acute hypoxic respiratory failure secondary to COVID-19 pneumonia and developed new-onset sinus bradycardia without a compensatory increase in heart rate in response to relative hypotension. Patient 2 is an 81-year-old male with a past medical history of an ascending aortic aneurysm, hypertension, and obstructive sleep apnoea who required intubation for COVID-19-induced acute hypoxic respiratory failure and exhibited new-onset sinus bradycardia followed by numerous episodes of haemodynamically significant accelerated idioventricular rhythm. Two weeks following the onset of SND, both patients remain in sinus bradycardia. DISCUSSION: COVID-19-associated SND has not previously been described. The potential mechanisms for SND in patients with COVID-19 include myocardial inflammation or direct viral infiltration. Patients diagnosed with COVID-19 should be monitored closely for the development of bradyarrhythmia and haemodynamic instability.

7.
Am J Cardiol ; 131: 67-73, 2020 09 15.
Article in English | MEDLINE | ID: mdl-32723557

ABSTRACT

The use of LDT may signify significant hemodynamic changes and left ventricular remodeling in severe aortic stenosis (AS). Therefore, we sought to determine whether loop diuretic therapy (LDT) is associated with adverse outcomes following transcatheter aortic valve implantation (TAVI) in patients with severe symptomatic AS. Subjects undergoing TAVI at a single institution from June 2008 to December 2017 were analyzed. LDT doses were normalized to oral furosemide daily equivalents. All outcomes were adjudicated using VARC2 criteria. Descriptive statistics, multivariate logistic regression, and propensity score matching were used. Of the 804 subjects studied, 48.3% were on pre-TAVI LDT with a mean dose of 51.1 mg furosemide dose-equivalents. Subjects on LDT were higher risk, frail patients with more co-morbidities including chronic kidney disease, coronary artery disease requiring prior bypass grafting, peripheral arterial disease, atrial fibrillation or flutter, and diabetes with more severe heart failure symptoms. Those on LDT also had worse left ventricular systolic function, lower transvalvular gradients, and markers of adverse left ventricular remodeling, including increased left ventricular mass index and higher rates of concentric and eccentric hypertrophy. On propensity-score matching, death within one year post-TAVI was borderline significantly higher in the pre-LDT as compared with no-LDT group (16.9% vs 10.4 %, p = 0.068). In conclusion, use of pre-TAVI LDT for severe symptomatic AS is associated with a trend towards worse 1-year mortality and is a marker of high-risk, frail individuals with advanced left ventricular remodeling.


Subject(s)
Aortic Valve Stenosis/surgery , Sodium Potassium Chloride Symporter Inhibitors/therapeutic use , Transcatheter Aortic Valve Replacement , Ventricular Remodeling/drug effects , Aged, 80 and over , Aortic Valve Stenosis/mortality , Female , Frail Elderly , Humans , Male , Propensity Score , Risk Assessment , Survival Rate
8.
Cardiovasc Revasc Med ; 21(10): 1305-1310, 2020 10.
Article in English | MEDLINE | ID: mdl-32192912

ABSTRACT

AIMS: Chronic total occlusion (CTO) has been linked to worse survival. While controversial and limited to observational data, successful CTO percutaneous coronary intervention (PCI) has been associated with improved left ventricular (LV) function and mortality. However, the role of CTO PCI prior to transcatheter aortic valve replacement (TAVR) is not clear. We sought to explore the prognostic impact of a pre-TAVR CTO on post-TAVR outcomes. METHODS AND RESULTS: We retrospectively reviewed 783 consecutive TAVR cases performed at a single tertiary care medical center. Pre-TAVR angiograms were analyzed for the presence of a CTO. At the time of TAVR, 12.6% (n = 99) patients had a CTO. At one-year post-TAVR, there was no significant association between the presence of a CTO and death (14.2% vs 13.1%, p = 0.75), functional status, quality of life, or adverse events. There was also no difference in long-term survival (4.1 years vs 4.1 years, p = 0.55). LV ejection fraction was lower in the CTO group at baseline and one year (p < 0.01). CONCLUSIONS: The presence of a CTO did not have any prognostic impact on mortality, change in LV function, or improvement in functional status and angina scores following TAVR in our cohort of elderly, high-risk patients. CTO before TAVR was associated with decreased ejection fraction at baseline and at one year.


Subject(s)
Aortic Valve Stenosis , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Observational Studies as Topic , Quality of Life , Retrospective Studies , Risk Factors , Treatment Outcome
9.
J Echocardiogr ; 17(1): 25-34, 2019 03.
Article in English | MEDLINE | ID: mdl-30465271

ABSTRACT

The advent of transcatheter aortic valve replacement (TAVR) has dramatically transformed the clinical approach to severe aortic stenosis. Over the last decade, several trials have shown the equivalence or even superiority of transcatheter valve replacement over the conventional surgical approach. As a result, TAVR as a treatment for severe, symptomatic aortic stenosis has rapidly extended from inoperable or prohibited-risk patients to intermediate-risk patients. The success of TAVR has led to the wide adaptation of this technique and, subsequently, a significant increase in the number of these procedures performed annually. As the number of these procedures is expected to further increase, especially if its indication will include those with low surgical risk, there is a great demand to improve patient recovery and early discharge without compromising outcomes. In this review, we will discuss the role of echocardiography in the perioperative planning and assessment of transcatheter aortic valve replacement. In addition, we will review the current evidence behind the use of intraprocedureal transthoracic echocardiography and the recommended steps for successful transition from transesophageal to transthoracic echocardiography.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Echocardiography/methods , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Echocardiography, Transesophageal/methods , Humans , Intraoperative Period
10.
Pacing Clin Electrophysiol ; 42(2): 146-152, 2019 02.
Article in English | MEDLINE | ID: mdl-30548869

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis. A frequent complication of TAVR is high-grade or complete atrioventricular (AV) block requiring a permanent pacemaker (PPM). There are little data on the long-term dependency on pacing after TAVR. The objective of this study was to determine the proportion of patients receiving a PPM for high-grade or complete AV block after TAVR who remain dependent on the PPM in follow-up and to determine any risk factors for, particularly the effect of postballoon dilation (PBD) on, pacemaker dependency. METHODS: Of 594 consecutive patients without prior PPM undergoing TAVR (81.9% balloon-expandable, 18.1% self-expandable valve), 67 (13.1%) received a PPM after TAVR. PPM dependency was defined as AV block with a ventricular escape rate of ≤ 40 beats/min. Patient and procedural characteristics were examined according to PPM dependency status. RESULTS: Of the 67 patients who received a PPM within 10 days after TAVR, 27/67 (40.3%) were dependent at first follow-up and only 9/41 (21.9%) at 1 year. PPM dependency was more common after a self-expanding valve (76.9% vs 31.5%, P < 0.01), in those who underwent PBD (66.7% vs 24.4%, P < 0.01), and in patients in persistent complete AV block at PPM implantation (62.5% vs 7.4%, P < 0.01). CONCLUSIONS: Fewer than half of patients who receive a new PPM following TAVR are pacemaker dependent at early follow-up (< 30 days). The use of self-expanding valves and PBD are associated with a markedly increased risk of PPM dependency.


Subject(s)
Atrioventricular Block/etiology , Atrioventricular Block/therapy , Pacemaker, Artificial , Postoperative Complications/etiology , Postoperative Complications/therapy , Transcatheter Aortic Valve Replacement/adverse effects , Aged, 80 and over , Atrioventricular Block/physiopathology , Female , Heart Conduction System , Humans , Male , Pacemaker, Artificial/adverse effects , Postoperative Complications/physiopathology , Recovery of Function , Retrospective Studies , Risk Assessment , Risk Factors
11.
Curr Opin Endocrinol Diabetes Obes ; 25(2): 130-136, 2018 04.
Article in English | MEDLINE | ID: mdl-29324459

ABSTRACT

PURPOSE OF REVIEW: The cholesterol content within atherogenic apolipoprotein-B (apoB) containing lipid particles is the center of consensus guidelines and clinicians' focus whenever evaluating a patient's risk for atherosclerotic cardiovascular disease. The pathobiology of atherosclerosis requires the retention of lipoprotein particles within the vascular intima over time followed by maladaptive inflammation resulting in plaque formation and rupture in some. The cholesterol content is widely variable within each particle creating either cholesterol-deplete or cholesterol-enriched particles. This variance in particle cholesterol content varies within and between individuals. Discordance analysis exploits this difference in cholesterol content of particles to demonstrate the differential significance of LDL-cholesterol (LDL-C) and non-HDL-C from measures of lipoprotein particle number in terms of assessing atherosclerotic cardiovascular disease risks. RECENT FINDINGS: Three studies have added to the growing body of literature of discordance analysis. Despite wide variability of discordance cutoffs, baseline risk of atherosclerotic disease, and populations sampled, the conclusion remains the same: risk of atherosclerotic disease follows apoB lipid particle concentration rather than cholesterol content of lipid particles. SUMMARY: In addition to traditional lipid fractions, assessments of atherogenic particle number should be strongly considered whenever assessing CVD risk in nontreated and treated individuals. There is a need for clinical trials that focus not only on the reduction in LDL-C but apoB, as well.


Subject(s)
Atherosclerosis/blood , Atherosclerosis/etiology , Biomarkers/blood , Cholesterol/blood , Lipoproteins/blood , Apolipoproteins B/blood , Atherosclerosis/diagnosis , Biomarkers/analysis , Cholesterol/analysis , Cholesterol, LDL/blood , Humans , Lipoproteins/analysis , Risk Assessment , Risk Factors
12.
MedEdPORTAL ; 14: 10730, 2018 07 13.
Article in English | MEDLINE | ID: mdl-30800930

ABSTRACT

Introduction: Inpatient telemetry monitoring is a commonly used technology designed to detect and monitor life-threatening arrhythmias. However, residents are rarely educated in the proper use and interpretation of telemetry monitoring. Methods: We developed a training module containing an educational video, PowerPoint presentation, and hands-on interactive learning session with a telemetry expert. The module highlights proper use of telemetry monitoring, recognition of telemetry artifact, and interrogation of telemetry to identify clinically significant arrhythmias. Learners completed pre- and postcurriculum knowledge-based assessments and a postcurriculum survey on their experience with the module. In total, the educational curriculum had three 60-minute sessions. Results: Thirty-two residents participated in the training module. Residents scored higher on the posttest (77% ± 12%) than on the pretest (70% ± 12%), t(31) = -4.3, p < .001. Wilcoxon signed rank tests indicated PGY-3s performed better on the posttest (Mdn = 0.86) than on the pretest (Mdn = 0.72), z = -2.19, p = .031. PGY-2s also performed better on the posttest (Mdn = 0.86) than on the pretest (Mdn = 0.76), z = -2.04, p = .042. There was no difference between pretest (Mdn = 0.66) and posttest (Mdn = 0.71) scores for PGY-1s, z = -1.50, p = .142. The majority of residents reported that the telemetry curriculum boosted their self-confidence, helped prepare them to analyze telemetry on their patients, and should be a required component of the residency. Discussion: This module represents a new paradigm for teaching residents how to successfully and confidently interpret and use inpatient telemetry.


Subject(s)
Teaching/standards , Telemetry/methods , Computer-Assisted Instruction/methods , Computer-Assisted Instruction/standards , Curriculum/trends , Educational Measurement/methods , Humans , Inpatients , Internship and Residency/methods , Simulation Training , Teaching/trends , Telemetry/statistics & numerical data
13.
Curr Opin Pulm Med ; 22(4): 378-85, 2016 07.
Article in English | MEDLINE | ID: mdl-27093476

ABSTRACT

PURPOSE OF REVIEW: Although thoracentesis is generally considered safe, procedural complications are associated with increased morbidity, mortality, and healthcare costs. In this article, we review the risk factors and prevention of the most common complications of thoracentesis including pneumothorax, bleeding (chest wall hematoma and hemothorax), and re-expansion pulmonary edema. RECENT FINDINGS: Recent data support the importance of operator expertise and the use of ultrasound in reducing the risk of iatrogenic pneumothorax. Although coagulopathy or thrombocytopenia and the use of anticoagulant or antiplatelet medications have traditionally been viewed as contraindications to thoracentesis, new evidence suggests that patients may be able to safely undergo thoracentesis without treating their bleeding risk. Re-expansion pulmonary edema, a rare complication of thoracentesis, is felt to result in part from the generation of excessively negative pleural pressure. When and how to monitor changes in pleural pressure during thoracentesis remains a focus of ongoing study. SUMMARY: Major complications of thoracentesis are uncommon. Clinician awareness of risk factors for procedural complications and familiarity with strategies that improve outcomes are essential components for safely performing thoracentesis.


Subject(s)
Hemorrhage/prevention & control , Pleural Diseases/prevention & control , Pulmonary Edema/prevention & control , Thoracentesis/adverse effects , Hematoma/etiology , Hematoma/prevention & control , Hemorrhage/etiology , Hemothorax/etiology , Hemothorax/prevention & control , Humans , Incidence , Pleural Diseases/etiology , Pneumothorax/etiology , Pneumothorax/prevention & control , Pressure , Pulmonary Edema/etiology , Risk Factors , Thoracentesis/statistics & numerical data , Thoracic Wall
SELECTION OF CITATIONS
SEARCH DETAIL
...