Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Biotechnol J ; 17(5): e2100433, 2022 May.
Article in English | MEDLINE | ID: mdl-35089643

ABSTRACT

Continuous chromatography is increasingly being used across the biotechnology industry due to its economic advantages. For adoption in commercial manufacturing, also models for virus clearance studies must be available. It is demonstrated how for a virus clearance study for a multispecific antibody, the continuous protein A capture chromatography process, being run on multiple interconnected columns, can be mimicked with only a single column. With this mimicking small-scale model, resources and complexity can be minimized, when conducting virus clearance studies at a contract research organization (CRO) lab. Obtained log reduction values (LRV) for murine leukemia virus (xMuLV) and minute virus of mice (MVM) virus, used as model viruses, are comparable to batch protein A chromatography and results described by other groups. The feasibility of this mimicking small-scale model helps to further reduce barriers to adoption when implementing continuous chromatography.


Subject(s)
Antibodies, Monoclonal , Viruses , Animals , Antibodies, Monoclonal/chemistry , Chromatography , Leukemia Virus, Murine , Mice , Staphylococcal Protein A/chemistry
2.
Biotechnol Rep (Amst) ; 26: e00465, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32420053

ABSTRACT

For the first time to our knowledge the implementation of a continuous protein A capture process for antibody applications (CoPACaPAnA) embedded in an end-to-end single-use 500 L GMP manufacturing downstream process of a multispecific monoclonal antibody (mAb) using a single-use SMB system was conducted. Throughout the last years, a change concerning the pipelines in pharmaceutical industry could be observed, moving to a more heterogeneous portfolio of antibodies, fusion proteins and nanobodies. Trying to adjust purification processes to these new modalities, a higher degree of flexibility and lower operational and capital expenditure is desired. The implementation of single-use equipment is a favored solution for increasing manufacturing agility and it has been demonstrated that continuous processing can be beneficial concerning processing cost and time. Reducing protein A resin resulted in 59% cost reduction for the protein A step, with additional cost reduction also for the intermediate and polishing step due to usage of disposable technology. The downstream process applied here consisted of three chromatography steps that were all conducted on a single-use SMB system, with the capture step being run in continuous mode while intermediate and polishing was conducted in batch mode. Further, two steps dedicated to virus inactivation/ removal and three filtration steps were performed, yielding around 100 g of drug substance going into clinical phase I testing. Therefore, in this study it has been demonstrated that employing a continuous capture within a GMP single-use downstream processing chain is feasible and worthy of consideration among the biotech industry for future application to modality-diverse pipelines.

3.
J Biotechnol ; 281: 168-174, 2018 Sep 10.
Article in English | MEDLINE | ID: mdl-30025795

ABSTRACT

The awareness about implementing continuous processing for biopharmaceutical products has significantly increased throughout the recent years not only at developmental scale but also for phase I supply in clinical trial manufacturing. In this study, we focused on upscaling continuous protein A chromatography from lab to pilot scale using the Cadence™ BioSMB PD and the Cadence™ BioSMB Process 80 system, respectively. Additionally, we evaluated hardware and software capability whilst running the system for 10 days non-stop using feed from a perfusion bioreactor. In terms of product quality and removal of impurities, comparable data was obtained regarding lab scale and production scale. Compared to batch mode, productivity was increased by 400 to 500%. Furthermore, the system worked accurately during the whole trial, proving its potential for the implementation into a hybrid or an end-to-end continuous process.


Subject(s)
Staphylococcal Protein A/chemistry , Animals , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/genetics , CHO Cells , Chromatography/methods , Computers , Cricetulus , Software
4.
J Biotechnol ; 259: 213-220, 2017 Oct 10.
Article in English | MEDLINE | ID: mdl-28684321

ABSTRACT

The protein A capture step is the main cost-driver in downstream processing, with high attrition costs especially when using protein A resin not until end of resin lifetime. Here we describe a feasibility study, transferring a batch downstream process to a hybrid process, aimed at replacing batch protein A capture chromatography with a continuous capture step, while leaving the polishing steps unchanged to minimize required process adaptations compared to a batch process. 35g of antibody were purified using the hybrid approach, resulting in comparable product quality and step yield compared to the batch process. Productivity for the protein A step could be increased up to 420%, reducing buffer amounts by 30-40% and showing robustness for at least 48h continuous run time. Additionally, to enable its potential application in a clinical trial manufacturing environment cost of goods were compared for the protein A step between hybrid process and batch process, showing a 300% cost reduction, depending on processed volumes and batch cycles.


Subject(s)
Chromatography, Affinity/economics , Chromatography, Affinity/methods , Animals , Antibodies, Monoclonal/analysis , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/isolation & purification , CHO Cells , Cricetinae , Cricetulus , Feasibility Studies , Staphylococcal Protein A/metabolism
5.
Biotechnol Prog ; 31(2): 578-84, 2015.
Article in English | MEDLINE | ID: mdl-25504543

ABSTRACT

Within the framework of process analytical technology, infrared spectroscopy (IR) has been used for characterization of biopharmaceutical production processes. Although noninvasive attenuated total reflection (ATR) spectroscopy can be regarded as gold standard within IR-based process analytics, simpler and more cost-effective mid-infrared (MIR) instruments might improve acceptability of this technique for high-level monitoring of small scale experiments as well as for academia where financial restraints impede the use of costly equipment. A simple and straightforward at-line mid-IR instrument was used to monitor cell viability parameters, activity of lactate dehydrogenase (LDH), amount of secreted antibody, and concentration of glutamate and lactate in a Chinese hamster ovary cell culture process, applying multivariate prediction models, including only 25-28 calibration samples per model. Glutamate amount could be predicted with high accuracy (R(2) 0.91 for independent test-set) while antibody concentration achieved good prediction for concentrations >0.4 mg L(-1) . Prediction of LDH activity was accurate except for the low activity regime. The model for lactate monitoring was only moderately good and requires improvements. Relative cell viability between 20 and 95% could be predicted with low error (8.82%) in comparison to reference methods. An initial model for determining the number of nonviable cells displayed only acceptable accuracy and requires further improvement. In contrast, monitoring of viable cell number showed better accuracy than previously published ATR-based results. These results prove the principal suitability of less sophisticated MIR instruments to monitor multiple parameters in biopharmaceutical production with relatively low investments and rather fast calibration procedures.


Subject(s)
Bioreactors , Cell Culture Techniques/methods , Spectrophotometry, Infrared/methods , Animals , CHO Cells , Cell Survival , Cricetinae , Cricetulus
6.
J Anal Methods Chem ; 2014: 657079, 2014.
Article in English | MEDLINE | ID: mdl-25371845

ABSTRACT

Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25-5 mg/mL) and analysis of total lipid or detergent species, as well as the identification of other biomolecules present in biological samples. The method utilizes a hydrophilic PTFE membrane engineered for presentation of aqueous samples in a dried format compatible with fast infrared analysis. Unlike classical quantification techniques, the reported method is amino acid sequence independent and thus applicable to complex samples of unknown composition. By comparison to existing platforms, this MIR-based method enables direct quantification using minimal sample volume (2 µL); it is well-suited where repeat access and limited sample size are critical parameters. Further, accurate results can be derived without specialized training or knowledge of IR spectroscopy. Overall, the simplified application and analysis system provides a more cost-effective alternative to high-throughput IR systems for research laboratories with minimal throughput demands. In summary, the MIR-based system provides a viable alternative to current protein quantitation methods; it also uniquely offers simultaneous qualification of other components, notably lipids and detergents.

7.
Biotechnol J ; 9(5): 698-701, 2014 May.
Article in English | MEDLINE | ID: mdl-24659538

ABSTRACT

The use of antigen-binding fragments (Fabs) as biotherapeutic agents is gaining interest and thus requires development of adequate purification strategies aimed at separating Fabs from other proteins. Thus, the feasibility of using a copolymer for separation of Fabs from monoclonal antibodies (mAbs) and fragment constant regions (Fcs) was evaluated, employing a blend of purified solutions of these proteins. The use of a copolymer exerting both hydrophobic as well as anionic properties resulted in high precipitation yields for both the mAb and Fc fragment, even at ionic strength of 150 mM NaCl. On the contrary, Fabs exhibited reduced precipitation yields upon copolymer addition. These observations are attributed to differences in protein physicochemical parameters, allowing mAbs and Fcs to be precipitated via conjoint electrostatic and hydrophobic interactions. In contrast, Fabs were mainly precipitated via electrostatic interactions, being reduced at higher ionic strength. This finding was corroborated by hydrophobicity analysis using 2-p-toluidinonaphthalene-6-sulfonate, showing enhanced hydrophobicity of Fcs compared to mAbs alone, while Fabs exhibited the lowest hydrophobicity. Within the context of increasing demand for Fabs as therapeutic proteins, these results may open up a simpler purification strategy for this protein class, potentially also to be implemented within the context of polymer-driven protein purification during fermentation.


Subject(s)
Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/isolation & purification , Immunoglobulin Fab Fragments/chemistry , Immunoglobulin Fab Fragments/isolation & purification , Recombinant Proteins/chemistry , Recombinant Proteins/isolation & purification , Biotechnology/methods , Feasibility Studies , Hydrophobic and Hydrophilic Interactions , Static Electricity
8.
Biotechnol Prog ; 29(6): 1484-93, 2013.
Article in English | MEDLINE | ID: mdl-24124128

ABSTRACT

This manuscript describes customization of copolymers to be used for polymer-driven protein purification in bioprocessing. To understand how copolymer customization can be used for fine-tuning, precipitation behavior was analyzed for five target antibodies (mAbs) and BSA as model impurity protein, at ionic strength similar to undiluted cell culture fluid. In contrast to the use of standardized homopolymers, customized copolymers, composed of 2-acrylamido-2-methylpropane sulfonic acid (AMPS) and 4-(acryloylamino)benzoic acid (ABZ), exhibited antibody precipitation yields exceeding 90%. Additionally, copolymer average molecular weight (Mw ) was varied and its influence on precipitation yield and contaminant coprecipitation was investigated. Results revealed copolymer composition as the major driving force for precipitation selectivity, which was also dependent on protein hydrophobicity. By adjusting ABZ content and Mw of the precipitant for each of the mAbs, conditions were found that allowed for high precipitation yield and selectivity. These findings may open up new avenues for using polymers in antibody purification processes.


Subject(s)
4-Aminobenzoic Acid/chemistry , Acrylamides/chemistry , Alkanesulfonates/chemistry , Antibodies, Monoclonal/isolation & purification , Polymers/chemistry , Antibodies, Monoclonal/chemistry , Cell Culture Techniques , Chemical Precipitation , Humans , Osmolar Concentration
9.
Biotechnol Bioeng ; 110(11): 2915-27, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23637026

ABSTRACT

We present a feasibility study for an antibody capturing process from clarified cell culture fluid using semi-selective protein precipitation with salt-tolerant copolymers. Protein precipitation is mediated by hydrophobic and electrostatic interactions with the copolymer that can be customized for the respective target. Precipitation yield with different copolymers at ionic strength of 2-22.5 mS cm⁻¹ and pH 5.0-pH 5.7 was evaluated using pure monoclonal antibody solutions. Optimized parameters were used to elucidate yield and purity of various antibodies precipitated at physiological conditions from cell culture fluid of CHO, NS0, and SP2/0 cell culture fluid. Precipitated protein was easily redissolved in small volume, enabling concentrating monoclonal antibodies (mAb) more than 40-fold and up to 100-fold, while residual polymer was removed to >98% using cationic polymer attached to silica flakes. mAb recovery of >90% and host cell protein clearance of >80% were achieved, not requiring any pre-dilution of cell culture fluid. Precipitation showed no impact on mAb binding affinity when compared to non-precipitated mAb. The obtained yield and purity were lower compared to a protein A based purification and loss of mAb was factor 1.5-3.0 higher. Yet, for high titer mAb purification processes being implemented in the future, precipitation is an attractive option due to its ease of scalability and cost-effectiveness.


Subject(s)
Antibodies/isolation & purification , Biological Products/isolation & purification , Chemical Fractionation/methods , Chemical Precipitation , Technology, Pharmaceutical/methods , Animals , Cell Culture Techniques/methods , Cell Line , Feasibility Studies , Hydrogen-Ion Concentration , Recombinant Proteins/isolation & purification , Salts/chemistry
10.
Biotechnol J ; 8(8): 912-7, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23712876

ABSTRACT

Therapeutic antibody purification involves several steps which potentially induce antibody aggregation. Currently, aggregate monitoring mainly employs chromatographic, SDS-PAGE and light scattering techniques. In this study, the feasibility of mid-infrared spectroscopy (MIR) for the quantification of soluble antibody aggregates was investigated. Several multivariate models were evaluated to quantify antibody aggregation in chromatography elution streams and in clarified CHO cell culture supernatants (a surrogate for bioreactor output). A general model was established that is applicable for aggregate quantification directly from different cell culture solutions. Real-process samples and process-sample mimics were used to verify the general aggregate quantification model using two different antibodies. Results showed good prediction ability down to 1% aggregate content. Together with recently published results using MIR for host cell protein and target protein quantification, the results presented here indicate that MIR could provide multi-parameter process information from a single, fast, cost-effective and straightforward measurement. In conclusion, our study demonstrates that MIR is suitable for aggregate quantification in therapeutic antibody purification processes.


Subject(s)
Antibodies, Monoclonal/analysis , Biotechnology/methods , Cell Culture Techniques/methods , Spectrophotometry, Infrared/methods , Animals , Antibodies, Monoclonal/isolation & purification , CHO Cells , Cricetinae , Cricetulus , Recombinant Proteins/analysis , Recombinant Proteins/isolation & purification , Solubility
11.
Biotechnol Bioeng ; 110(1): 252-9, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22811255

ABSTRACT

Process development in up- and downstream processing requires enhanced, non-time-consuming, and non-expensive monitoring techniques to track product purity, for example, the level of endotoxins, viral particles, and host cell proteins (HCPs). Currently, HCP amounts are measured by laborious and expensive HCP-enzyme-linked immunosorbent assay (ELISA) assays best suited for measuring HCP amounts in the low concentration regime. The measurement of higher HCP amounts using this method requires dilution steps, adding dilution errors to the measurement. In this work we evaluated the suitability of attenuated total reflection spectroscopy for HCP quantification in process development, using clarified cell culture fluid from monoclonal antibody producing Chinese hamster ovary-cells after treatment with different polyelectrolytes for semi-selective clarification. Forty undiluted samples were chosen for multivariate data analysis in the middle infrared range and predicted HCP-values were in good agreement with results obtained by an ELISA-assay, suggesting the suitability of this new method for HCP-quantification. As this method is able to quantify HCP titers ranging from approximately at least 20,000-200,000 ng mL(-1), it is suitable especially for monitoring of process development steps with higher HCP concentrations, omitting dilution errors associated with ELISA assays.


Subject(s)
Biotechnology/methods , Proteins/analysis , Spectroscopy, Fourier Transform Infrared/methods , Animals , Antibodies, Monoclonal/isolation & purification , CHO Cells , Cricetinae , Cricetulus , Electrolytes/chemistry , Enzyme-Linked Immunosorbent Assay , Mass Spectrometry , Polymers/chemistry , Principal Component Analysis , Proteins/chemistry , Recombinant Proteins/isolation & purification
12.
Biotechnol Prog ; 29(1): 265-74, 2013.
Article in English | MEDLINE | ID: mdl-23074023

ABSTRACT

Production of recombinant proteins, e.g. antibodies, requires constant real-time monitoring to optimize yield and quality attributes and to respond to changing production conditions, such as host cell protein (HCP) titers. To date, this monitoring of mammalian cell culture-based processes is done using laborious and time consuming enzyme-linked immunosorbent assays (ELISA), two-dimensional sodium dodecylsulphate polyacrylamide gel electrophoresis, and chromatography-based systems. Measurements are usually performed off-line, requiring regular sample withdrawal associated with increased contamination risk. As information is obtained retrospectively, the reaction time to adapt to process changes is too long, leading to lower yield and higher costs. To address the resulting demand for continuous online-monitoring systems, we present a feasibility study using attenuated total reflection spectroscopy (ATR) to monitor mAb and HCP levels of NS0 cell culture in situ, taking matrix effects into account. Fifty-six NS0 cell culture samples were treated with polyelectrolytes for semi-selective protein precipitation. Additionally, part of the samples was subjected to filtration prior to analysis, to change the background matrix and evaluate effects on chemometric quantification models. General models to quantify HCP and mAb in both filtered and unfiltered matrix showed lower prediction accuracy compared to models designed for a specific matrix. HCP quantification in the range of 2,000-55,000 ng mL(-1) using specific models was accurate for most samples, with results within the accepted limit of an ELISA assay. In contrast, mAb prediction was less accurate, predicting mAb in the range of 0.2-1.7 g L(-1) . As some samples deviated substantially from reference values, further investigations elucidating the suitability of ATR for monitoring are required.


Subject(s)
Antibodies, Monoclonal/analysis , Proteins/analysis , Animals , Cells, Cultured , Enzyme-Linked Immunosorbent Assay , Fluorescence , Mice , Principal Component Analysis , Spectroscopy, Fourier Transform Infrared
SELECTION OF CITATIONS
SEARCH DETAIL
...