Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Int J Cardiol ; 384: 55-61, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37149007

ABSTRACT

BACKGROUND: In terms of pathophysiology, tricuspid regurgitation (TR), right ventricular function and pulmonary artery pressure are linked to each other. Our aim was to analyze whether the echocardiography-derived right ventricular free wall longitudinal strain/pulmonary artery systolic pressures (RVFWLS/PASP) ratio can improve risk stratification in patients with severe tricuspid regurgitation (TR). METHODS: In this single-center retrospective study, 250 consecutive patients with severe TR were enrolled from December 2015 to December 2018. Baseline clinical and echocardiographic parameters were collected. Echocardiography-derived TAPSE/PASP and RVFWLS/PASP were evaluated. The primary endpoint was all-cause mortality. RESULTS: Out of 250 consecutive patients, 171 meet inclusion criteria. Patients were predominantly female, with several cardiovascular risk factors and comorbidities. RVFWLS/PASP ≤0.34%/mmHg (AUC 0.68, p < 0.001, sensitivity 70%, specificity 67%) was associated with baseline clinical RV heart failure (p = 0.03). After univariate and multivariate analyses, RVFWLS/PASP, but not TAPSE/PASP, independently correlated with all-cause mortality (HR 0.004, p = 0.02). Patients with RVFWLS/PASP >0.26%/mmHg (AUC 0.74, p < 0.001, sensitivity 77%, specificity 52%) showed higher survival rates (p = 0.02). In addition at 24 months follow-up, the Kaplan-Meyer curves showed patients with RVFWLS >14% & RVFWLS/PASP >0.26%/mmHg had the best survival rate compared to patients without. CONCLUSION: RVFWLS/PASP is independently associated with baseline RV heart failure and poor long-term prognosis in patients with severe TR.


Subject(s)
Heart Failure , Hypertension, Pulmonary , Tricuspid Valve Insufficiency , Ventricular Dysfunction, Right , Humans , Female , Male , Prognosis , Tricuspid Valve Insufficiency/diagnostic imaging , Blood Pressure , Echocardiography, Doppler , Retrospective Studies , Ventricular Function, Right/physiology , Pulmonary Artery/diagnostic imaging
2.
J Interv Card Electrophysiol ; 65(1): 15-24, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34313898

ABSTRACT

PURPOSE: To assess the role of intense physical activity (PA) on recurrence after ventricular tachycardia (VT) ablation in arrhythmogenic cardiomyopathy (ACM). METHODS: We retrospectively analyzed 63 patients with definite diagnosis of ACM who underwent to catheter ablation (CA) of VT. PA was quantified in METs per week by IPAQ questionnaire in 51 patients. VT-free survival time after ablation was analyzed by Kaplan-Meier's curves. RESULTS: The weekly amount of PA was higher in patients with VT recurrence (2303.1 METs vs 1043.5 METs, p = 0.042). The best cutoff to predict VT recurrence after CA was 584 METs/week (AUC = 0.66, sensibility = 85.0%, specificity = 45.2%). Based on this cutoff, 34 patients were defined as high level athletes (Hi-PA) and 17 patients as low-level athletes (Lo-PA). During a median follow-up of 32.0 months (11.5-65.5), 22 patients (34.9%) experienced VT recurrence. Lo-PA patients had a longer VT-free survival, compared with Hi-PA patients (82.4% vs 50.0%, log-rank p = 0.025). At Cox multivariate analysis, independent predictors of the VT recurrence were PA ≥ 584 METs/week (Hi-PA) (HR = 2.61, CI 95% 1.03-6.58, p = 0.04) and late potential (LP) abolition (HR = 0.38, CI 95% 0.16-0.89, p = 0.03). CONCLUSIONS: PA ≥ 584 METs/week and LP abolition were independent predictors of VT recurrence after ablation.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Catheter Ablation , Tachycardia, Ventricular , Cardiomyopathies/surgery , Exercise , Humans , Recurrence , Retrospective Studies , Risk Factors , Treatment Outcome
3.
Pacing Clin Electrophysiol ; 45(1): 23-34, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34841552

ABSTRACT

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT). METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography. RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported. CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures , Embolic Protection Devices , Stroke/prevention & control , Thrombosis/surgery , Aged , Echocardiography, Transesophageal , Female , Humans , Male , Prospective Studies , Septal Occluder Device
4.
Minerva Cardiol Angiol ; 69(6): 684-706, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33944538

ABSTRACT

Mitral regurgitation is the most prevalent valve disease worldwide. Percutaneous mitral valve interventions are emerging as alternative options for high-risk patients with severe mitral regurgitation not eligible for conventional surgery. Accurate patient selection is based on a detailed pre-procedural multimodality imaging evaluation. Morphology and functional anatomy of the mitral valve should be evaluated to determine the feasibility of treatments and to identify the best therapeutic approach. The procedures are guided by fluoroscopy, transesophageal echocardiography and fusion imaging, ensuring a continuous communication between the interventionalist and the imaging specialist. The present review will cover the pre-procedural planning and the intra-procedural guidance of the most used transcatheter approaches in the setting of native mitral valve regurgitation: edge to edge repair, percutaneous direct and indirect annuloplasty, transapical beating-heart chordal implantation and transcatheter mitral valve replacement.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Echocardiography, Transesophageal , Humans , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/surgery
5.
Catheter Cardiovasc Interv ; 98(1): E163-E170, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33797142

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the impact of edge-to-edge PMVR on short and mid-term clinical outcomes in patients with CS and severe MR. BACKGROUND: Severe mitral regurgitation (MR) in the setting of cardiogenic shock (CS) is associated with three times higher risk of 1-year mortality. In refractory CS, edge-to-edge percutaneous mitral valve repair (PMVR) can be a potential therapeutic option. METHODS: We retrospectively included consecutive patients with refractory CS and concomitant severe MR treated with MitraClip® system. CS was defined according to the criteria used in the SHOCK trial and procedural success according to Mitral Valve Academic Research Consortium (MVARC) criteria. The 30-day and 6-month mortality were the primary and secondary endpoints respectively. RESULTS: Thirty-one patients (median age 73 years [interquartile range, IQR 66-78], 25.8% female), STS mortality score 37.9 [IQR 30.4-42.4]), with CS and concomitant severe MR treated with edge-to-edge PMVR were retrospectively enrolled. Procedural success was 87.1%. Thirty-day and 6-month survival rates were 78.4 and 45.2% respectively. Univariate Cox Regression Model analysis showed that procedural success was a predictor of both 30-day (HR = 0.12, 95% CI 0.03-0.55, p < .01) and 6-month survival (HR = 0.22, 95% CI 0.06-0.84, p = .027). CONCLUSIONS: Edge-to-edge PMVR in patients with CS and concomitant severe MR was associated with good procedural safety and success with acceptable short and mid-term survival rates. It could be considered a bailout option in this setting of patients.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Retrospective Studies , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Treatment Outcome
6.
J Cardiovasc Electrophysiol ; 32(5): 1337-1345, 2021 05.
Article in English | MEDLINE | ID: mdl-33682256

ABSTRACT

BACKGROUND: Ventricular arrhythmias (VAs) are rare in pediatric patients, especially in absence of structural heart disease (SHD). Few data are available regarding the invasive VAs treatment with catheter ablation (CA) in pediatric patients and predictors of outcomes have not been fully investigated. OBJECTIVE: To describe the clinical presentation, procedural characteristics, and outcomes in pediatric patients undergoing CA for VAs. METHODS: Eighty-one consecutive pediatric patients (58 male [72%], 15.5 ± 2.2 years) treated by CA for ventricular tachycardia (VT) or premature ventricular beats (PVBs) were retrospectively evaluated. Study endpoints were VAs recurrence and mortality for any cause. RESULTS: Ninety-five procedures were performed in 81 patients, 52 (55%) PVBs and 43 (45%) VT ablations. During a follow-up of 35.0 months (interquartile range = 13.0-71.0), 14 patients (14.7%) had a VA recurrence: 11 (33.3%) patients treated with CA for VT and 3 (6.2%) patients treated for PVBs (p < .001). One patient (1%) died 26 months after the procedure during an electrical storm. Patients with SHD had higher VAs recurrence rate, as compared with idiopathic VAs (pairwise log-rank p < .001). Patients treated with CA for VT had higher VA recurrence rate, as compared with PVB patients (pairwise log-rank p = .002). At Cox multivariate analysis only SHD was an independent predictor of VAs recurrence (hazard ratio = 5.56, 95% confidence interval = 2.68-11.54, p < .001). CONCLUSION: CA of VAs is effective and safe in a pediatric population. CA of idiopathic and fascicular VAs are associated with lower recurrence rate, than VAs in the setting of SHD.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Catheter Ablation/adverse effects , Child , Humans , Male , Recurrence , Retrospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
7.
Eur Heart J Cardiovasc Imaging ; 22(8): 868-875, 2021 07 20.
Article in English | MEDLINE | ID: mdl-33623973

ABSTRACT

AIMS: The aim of this study is to analyse the prognostic implications of right ventricular (RV) dysfunction as detected by strain analysis in patients with severe tricuspid regurgitation (TR). The evaluation of RV systolic function in presence of severe TR is of paramount importance for operative risk stratification; however, it remains challenging, as conventional echocardiographic indexes usually lead to overestimation. METHODS AND RESULTS: We enrolled 250 consecutive patients with severe TR referred to our centre. Baseline clinical and echocardiographic data and follow-up outcomes were collected. Patients were predominantly female, with multiple cardiovascular risk factors and comorbidities, history of heart failure, and atrial fibrillation. Most of them had presented with clinical signs of RV heart failure (RVHF) and advanced New York Heart Association class. The RV strain analysis [both RV free wall longitudinal strain (RVFWLS) and RV global longitudinal strain (RVGLS)] reclassified ∼42-56% of patients with normal RV systolic function according to conventional parameters in patients with impaired RV systolic function. RVFWLS ≤17% (absolute values, AUC: 0.66, P = 0.002) predicted the presence of RVHF [odds ratio (OR) 0.93, P = 0.01]. At follow-up, patients with RVFWLS >14% (absolute values, AUC: 0.70, P = 0.001, sensitivity 72%, specificity 54%) showed a better survival (P = 0.01). CONCLUSION: Different ranges of RVFWLS have different implications in patients with severe TR, allowing to identify a preclinical and a clinical window, with correlations to RVHF and survival.


Subject(s)
Tricuspid Valve Insufficiency , Ventricular Dysfunction, Right , Echocardiography , Female , Humans , Prognosis , Tricuspid Valve Insufficiency/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Function, Right
8.
J Am Soc Echocardiogr ; 34(6): 604-613, 2021 06.
Article in English | MEDLINE | ID: mdl-33453367

ABSTRACT

BACKGROUND: Whether fluoroscopic-echocardiographic fusion imaging (FI) might offer added value for intraprocedural guidance during transcatheter edge-to-edge mitral valve repair is yet unknown, and few data exist regarding the safety and feasibility of this novel technology. METHODS: The aim of this single-center study was to test and validate a FI protocol for intraprocedural monitoring of transcatheter edge-to-edge mitral valve repair and assess its clinical usefulness. Eighty patients underwent MitraClip implantation using FI guidance (FI+) for either degenerative (35%) or functional (65%) mitral regurgitation and were compared with the last 80 patients before FI introduction, treated using conventional echocardiography and fluoroscopic monitoring (FI-). RESULTS: The number of patients treated for functional and degenerative mitral regurgitation was similar between the FI+ and FI- groups, as well as the number of devices implanted (1.51 ± 0.5 vs 1.58 ± 0.6, P = .46). The prevalence of complex mitral anatomy for percutaneous repair was high (32.5%, up to 39.2% in the hybrid arm). Fluoroscopy time was significantly lower in FI+ patients (37.3 ± 14.6 vs 48.3 ± 28.3 min, P = .003), but not kerma area product (91.5 ± 74.1 vs 108.8 ± 105.0 Gy · cm2, P = .23) or procedural time (92.2 ± 36.1 vs 103.1 ± 42.7 min, P = .086). After adjusting for confounding factors (MitraClip XT device and complex anatomy), FI reduced fluoroscopy time (coefficient = -10.4 min; 95% CI, -18.03 to -2.82; P = .007) and improved procedural success at the end of the procedure (odds ratio, 2.87; 95% CI, 1.00 to 8.24; P = .049) and discharge (odds ratio, 2.24; 95% CI, 1.04 to 4.80; P = .039). Rates of periprocedural complications were similar in both groups (8.9% vs 13.0%, P = .40). CONCLUSIONS: The authors describe the systematic use of an FI protocol for intraprocedural guidance during transcatheter edge-to-edge mitral valve repair, demonstrating a reduction in fluoroscopy time and an improvement in procedural success in a population with a high prevalence of challenging mitral anatomy for percutaneous repair.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Echocardiography , Fluoroscopy , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery
10.
Echocardiography ; 37(12): 2071-2081, 2020 12.
Article in English | MEDLINE | ID: mdl-33026122

ABSTRACT

AIMS: Aortic stenosis (AS) grading by 2D-transthoracic echocardiography (2D-TTE) aortic valve area (AVA) calculation is limited by left ventricular outflow tract (LVOT) area underestimation. The combination of Doppler parameters with 3D LVOT area obtained by multidetector computed tomography (MDCT) can improve AS grading, reconciling discordant 2D-TTE findings. This study aimed to systematically evaluate the role of 3D-transesophageal echocardiography (3D-TEE) in AS grading using MDCT as reference standard. METHODS AND RESULTS: 288 patients (81 ± 6.3 years, 52.4% female) with symptomatic AS underwent 2D-TTE, 3D-TEE, and MDCT for transcatheter aortic valve implantation. Doppler parameters were combined with 3D LVOT areas measured by manual and semi-automated software 3D-TEE and by MDCT to calculate AVA, reassessing AS severity. Both 3D-TEE modalities demonstrated good correlation with MDCT, with excellent intra-observer and inter-observer variability. Compared to MDCT, 3D-TEE measurements significantly underestimated AVA (PANOVA  < .0001), although the difference was clinically acceptable. Compared to 2D-TTE, 3D-TEE manual and semi-automated software reclassified severe AS in 21.9% and 25.2% of cases, respectively (P < .0001), overcame grading parameters discordance in more than 40% of cases in patients with low-gradient AS (P < .0001) and reduced the proportion of low-flow states in nearly 75% of cases when combined to stroke volume index assessment (P < .0001). 3D-TEE imaging modalities showed a reduction in the proportion of patients with low-gradient and pathological AVA as defined by 2D-TTE, and improved AVA and mean pressure gradient agreement with current guidelines cutoff values. CONCLUSION: 3D-TEE AVA calculation is a reliable tool for AS grading with excellent reproducibility and good correlation with MDCT measurements.


Subject(s)
Aortic Valve Stenosis , Echocardiography, Three-Dimensional , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Echocardiography, Transesophageal , Female , Humans , Male , Reproducibility of Results
11.
G Ital Cardiol (Rome) ; 21(4 Suppl 2): 34S-41S, 2020 04.
Article in Italian | MEDLINE | ID: mdl-32250368

ABSTRACT

The echocardiographic-fluoroscopic fusion imaging tool is able to acquire imaging data from both fluoroscopy and transesophageal images and co-register and align them in the three-dimensional space and time by putting onto the same coordinate system. In this way the soft tissues that are well visualized by echocardiography and the metallic materials (catheters and devices), better imaged by fluoroscopy, are displayed in the standard fluoroscopic projections in a hybrid image in real time. In this review, we describe the basic technical aspects and its main applications in transcatheter structural heart interventions.


Subject(s)
Echocardiography, Three-Dimensional/methods , Fluoroscopy/methods , Heart Diseases/diagnostic imaging , Cardiac Catheterization , Heart Diseases/therapy , Humans , Imaging, Three-Dimensional/methods , Multimodal Imaging/methods
13.
J Invasive Cardiol ; 32(5): 180-185, 2020 May.
Article in English | MEDLINE | ID: mdl-32045345

ABSTRACT

OBJECTIVE: To evaluate the impact of left ventricular outflow tract calcification (LVOT-CA) localization and extension on permanent pacemaker implantation (PPI) rates after transcatheter aortic valve implantation (TAVI) with second-generation devices. METHODS: This single-center retrospective study included all consecutive patients who underwent transfemoral TAVI with second-generation devices at San Raffaele Hospital in Milan, Italy from January 2014 to June 2017. The localization and extension of LVOT-CA were evaluated using computed tomography imaging; LVOT regions were categorized according to the overlying coronary cusps. RESULTS: The study population consisted of 377 patients, of which LVOT-CA was present in 133 patients (35.3%). Patients with LVOT-CA had significantly a higher rate of post-TAVI PPI (32.0% vs 19.2% in patients with no LVOT-CA; P<.01). Multivariable analysis demonstrated LVOT-CA in the non-coronary cusp, as well as preprocedural right bundle-branch block, age, body mass index, and mechanically expanded prosthesis implantation, to be strong independent predictors of PPI. CONCLUSIONS: LVOT-CA in the non-coronary cusp is a strong independent predictor of PPI after TAVI with second-generation devices. Further studies are needed to confirm these data in a larger, multicenter population.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Humans , Italy , Multidetector Computed Tomography , Pacemaker, Artificial/adverse effects , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
14.
J Invasive Cardiol ; 31(9): E274-E276, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31478896

ABSTRACT

Three-dimensional multiplanar reconstruction was used to diagnose recurrence of mitral regurgitation after MitraClip implantation in a 71-year-old man. Subsequent mitral valve surgery in such a case is high risk, and repeat MitraClip intervention could be feasible but is technically challenging. This imaging series demonstrates that LVAD implantation may be a solution to address MitraClip failure.


Subject(s)
Cardiac Catheterization/methods , Cardiac Surgical Procedures/methods , Heart-Assist Devices , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnosis
16.
J Am Soc Echocardiogr ; 32(6): 730-736, 2019 06.
Article in English | MEDLINE | ID: mdl-31171107

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative treatment in surgically intermediate- or high-risk patients with classical low-flow, low-gradient (LFLG) aortic stenosis (AS). The objective of this study was to investigate whether two-dimensional (2D) speckle-tracking echocardiography (STE) can predict left ventricular (LV) flow reserve during dobutamine stress echocardiography (DSE) and remodeling after TAVR in patients with LFLG AS. METHODS: Seventy-five symptomatic patients with severe LFLG AS were recruited (mean age, 77.6 ± 8.4 years). Patients underwent a complete clinical evaluation, standard echocardiography, 2D STE, and DSE. Echocardiographic analysis was performed before and 6 months after TAVR using global longitudinal strain (GLS) measured on 2D STE. RESULTS: All patients received self-expanding transcatheter prosthetic valves. Six months after TAVR, LV GLS (12.8 ± 3.2% vs 16.3 ± 4.2%, P < .0001) significantly increased. In a multivariate analysis, LV GLS before TAVR (P < .0001) was an independent predictor of LV flow reserve during DSE. By receiver operating characteristic curve analysis, a cutoff value for LV GLS of ≤12% well distinguished patients without significant flow reserve and with lack of positive remodeling after TAVR at follow-up. These results support the hypothesis that myocardial analysis by 2D STE at baseline can be useful for the identification of patients with LFLG AS who would benefit from TAVR. CONCLUSIONS: The results of this study underline the predictive value of LV GLS on flow reserve during DSE and on global LV remodeling after TAVR in patients with LFLG AS. Cutoff values for LV GLS could be used to identify patients responding better to TAVR.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography/methods , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Remodeling , Aged , Aortic Valve Stenosis/physiopathology , Echocardiography, Stress , Electrocardiography , Female , Humans , Male , Prospective Studies , Tomography, X-Ray Computed , Ventricular Dysfunction, Left/physiopathology
18.
G Ital Cardiol (Rome) ; 20(2): 85-96, 2019 Feb.
Article in Italian | MEDLINE | ID: mdl-30747924

ABSTRACT

Tricuspid regurgitation is a common finding in patients with left-sided heart disease with prognostic implications. In addition, isolated tricuspid valve surgery is associated with high mortality and is infrequently performed. Hence, a largely unmet clinical need exists and less invasive therapeutic options are emerging: multiple percutaneous therapies have been developed, including tricuspid valve repair or replacement. This review aims to provide an overview with diagnostic and clinical perspectives, potential challenges and future directions.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Tricuspid Valve Insufficiency/surgery , Humans , Prognosis , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/epidemiology
19.
Eur Heart J Cardiovasc Imaging ; 20(1): 45-55, 2019 01 01.
Article in English | MEDLINE | ID: mdl-29420710

ABSTRACT

Aims: A 3D transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced. The system automatically configures a geometric model of the aortic root and performs quantitative analysis of these structures. We compared the measurements of the aortic annulus (AA) obtained by semi-automated 3D-TOE quantitative software and manual analysis vs. multislice computed tomography (MSCT) ones. Methods and results: One hundred and seventy-five patients (mean age 81.3 ± 6.3 years, 77 men) who underwent both MSCT and 3D-TOE for annulus assessment before transcatheter aortic valve implantation were analysed. Hypothetical prosthetic valve sizing was evaluated using the 3D manual, semi-automated measurements using manufacturer-recommended CT-based sizing algorithm as gold standard. Good correlation between 3D-TOE methods vs. MSCT measurements was found, but the semi-automated analysis demonstrated slightly better correlations for AA major diameter (r = 0.89), perimeter (r = 0.89), and area (r = 0.85) (all P < 0.0001) than manual one. Both 3D methods underestimated the MSCT measurements, but semi-automated measurements showed narrower limits of agreement and lesser bias than manual measurements for most of AA parameters. On average, 3D-TOE semi-automated major diameter, area, and perimeter underestimated the respective MSCT measurements by 7.4%, 3.5%, and 4.4%, respectively, whereas minor diameter was overestimated by 0.3%. Moderate agreement for valve sizing for both 3D-TOE techniques was found: Kappa agreement 0.5 for both semi-automated and manual analysis. Interobserver and intraobserver agreements for the AA measurements were excellent for both techniques (intraclass correlation coefficients for all parameters >0.80). Conclusion: The 3D-TOE semi-automated analysis of AA is feasible and reliable and can be used in clinical practice as an alternative to MSCT for AA assessment.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography, Three-Dimensional , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Image Interpretation, Computer-Assisted , Prosthesis Fitting , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Contrast Media , Female , Humans , Male , Reproducibility of Results , Software , Tomography, X-Ray Computed , Treatment Outcome , Triiodobenzoic Acids
SELECTION OF CITATIONS
SEARCH DETAIL
...