Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
Neuroimage ; 45(1): 215-23, 2009 Mar 01.
Article in English | MEDLINE | ID: mdl-19056499

ABSTRACT

This study compared sensitivity of FDG-PET, MR morphometry, and diffusion tensor imaging (DTI) derived fractional anisotropy (FA) measures to diagnosis and memory function in mild cognitive impairment (MCI). Patients (n=44) and normal controls (NC, n=22) underwent FDG-PET and MRI scanning yielding measures of metabolism, morphometry and FA in nine temporal and parietal areas affected by Alzheimer's disease and involved in the episodic memory network. Patients also underwent memory testing (RAVLT). Logistic regression analysis yielded 100% diagnostic accuracy when all methods and ROIs were combined, but none of the variables then served as unique predictors. Within separate ROIs, diagnostic accuracy for the methods combined ranged from 65.6% (parahippocampal gyrus) to 73.4 (inferior parietal cortex). Morphometry predicted diagnostic group for most ROIs. PET and FA did not uniquely predict group, but a trend was seen for the precuneus metabolism. For the MCI group, stepwise regression analyses predicting memory scores were performed with the same methods and ROIs. Hippocampal volume and FA of the retrosplenial WM predicted learning, and hippocampal metabolism and parahippocampal cortical thickness predicted 5 minute recall. No variable predicted 30 minute recall independently of learning. In conclusion, higher diagnostic accuracy was achieved when multiple methods and ROIs were combined, but morphometry showed superior diagnostic sensitivity. Metabolism, morphometry and FA all uniquely explained memory performance, making a multi-modal approach superior. Memory variation in MCI is likely related to conversion risk, and the results indicate potential for improved predictive power by the use of multimodal imaging.


Subject(s)
Cognition Disorders/pathology , Cognition Disorders/physiopathology , Memory , Parietal Lobe/pathology , Parietal Lobe/physiopathology , Temporal Lobe/pathology , Temporal Lobe/physiopathology , Adult , Aged , Brain Mapping/methods , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Nerve Net/pathology , Nerve Net/physiopathology , Neural Pathways/pathology , Neural Pathways/physiopathology , Positron-Emission Tomography/methods
2.
AJNR Am J Neuroradiol ; 29(6): 1183-9, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18544670

ABSTRACT

BACKGROUND AND PURPOSE: Mild cognitive impairment (MCI) may affect several cognitive domains, including attention and reasoning, but is often first characterized by memory deficits. The purpose of this study was to ask these 2 questions: 1) Can levels of CSF tau proteins and amyloid beta 42 peptide explain thinning of the cerebral cortex in patients with MCI? 2) How are brain morphometry, CSF biomarkers, and apolipoprotein E (APOE) allelic variation related to episodic memory function in MCI? MATERIALS AND METHODS: Hippocampal volume and cortical thickness were estimated by MR imaging and compared for patients with MCI (n = 18) and healthy controls (n = 18). In addition, regions of interest (ROIs) were selected in areas where the MCI group had atrophy and which overlapped with the episodic memory network (temporal, entorhinal, inferior parietal, precuneus/posterior cingulate, and frontal). Relationships among morphometry, CSF biomarkers, APOE, and memory were tested. The analyses were repeated with an independent sample of patients with MCI (n = 19). RESULTS: Patients with MCI and pathologic CSF values had hippocampal atrophy. However, both patients with pathologic and patients with nonpathologic CSF had a thinner cortex outside the hippocampal area. CSF pathology was related to hippocampal volume, whereas relationships with cortical thickness were found mainly in one of the samples. Morphometry correlated robustly with memory performance across MCI samples, whereas less stable results were found for tau protein. CONCLUSION: The differences in hippocampal volume between the MCI and the healthy control groups were only found in patients with pathologic CSF biomarkers, whereas differences in cortical thickness were also found for patients without such pathologic features. Morphometry in areas in the episodic memory network was robustly correlated with memory performance. It is speculated that atrophy in these areas may be associated with the memory problems seen in MCI.


Subject(s)
Amyloid beta-Peptides/cerebrospinal fluid , Cognition Disorders/cerebrospinal fluid , Cognition Disorders/diagnosis , Hippocampus/pathology , Memory Disorders/cerebrospinal fluid , Memory Disorders/diagnosis , Memory , Peptide Fragments/cerebrospinal fluid , tau Proteins/cerebrospinal fluid , Adult , Aged , Cognition Disorders/complications , Female , Humans , Male , Memory Disorders/complications , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic
3.
Acta Neurol Scand Suppl ; 187: 68-71, 2007.
Article in English | MEDLINE | ID: mdl-17419833

ABSTRACT

INTRODUCTION: We present a patient with a left anteromedial thalamic lesion with an amnesic syndrome. The patient underwent neuropsychological testing, cerebrospinal fluid (CSF) analyses, magnetic resonance imaging (MRI) [T2, flair, and diffusion tensor imaging (DTI)] and [18F]-2-fluoro-deoxy-d-glucose positron emission tomography (FDG-PET) to assess indirect effects of thalamic lesions on cortical function. CASE REPORT: A 67-year-old right-handed woman was admitted to a university-based memory unit because of memory and concentration problems. Neuropsychological testing revealed dysfunction of episodic memory, semantic memory and working memory. General intellectual function and attention capacity were preserved. MRI revealed an anteromedial thalamic lesion in the left hemisphere. FDG-PET showed decreased uptake in the frontal, parietal and temporal lobes of the left hemisphere. Regions of interest (ROI) in white matter were selected and left and right hemispheres were compared. Fractional anisotropy (FA) in ROI representing thalamo-cortical connections were decreased in the left hemisphere when compared with the right. CONCLUSION: The results show the importance of a network that include the anterior and dorsomedian nuclei, which influence the activity in areas of the cortex responsible for memory processes. The imaging findings suggest that areas of cortical diaschisis after thalamic infarction correspond to areas affected by thalamo-cortical fibre loss as measured with FA.


Subject(s)
Amnesia/etiology , Amnesia/physiopathology , Memory Disorders/etiology , Memory Disorders/physiopathology , Stroke/complications , Stroke/physiopathology , Thalamic Diseases/complications , Thalamic Diseases/physiopathology , Thalamus/physiopathology , Aged , Amnesia/diagnostic imaging , Anterior Thalamic Nuclei/diagnostic imaging , Anterior Thalamic Nuclei/pathology , Anterior Thalamic Nuclei/physiopathology , Cerebral Cortex/diagnostic imaging , Cerebral Cortex/physiopathology , Efferent Pathways/diagnostic imaging , Efferent Pathways/pathology , Efferent Pathways/physiopathology , Female , Fluorodeoxyglucose F18 , Functional Laterality/physiology , Humans , Magnetic Resonance Imaging , Mediodorsal Thalamic Nucleus/diagnostic imaging , Mediodorsal Thalamic Nucleus/pathology , Mediodorsal Thalamic Nucleus/physiopathology , Memory/physiology , Memory Disorders/diagnostic imaging , Neuropsychological Tests , Positron-Emission Tomography , Radiography , Stroke/diagnostic imaging , Thalamic Diseases/diagnostic imaging , Thalamus/diagnostic imaging , Thalamus/pathology
4.
Acta Oncol ; 39(1): 105-9, 2000.
Article in English | MEDLINE | ID: mdl-10752663

ABSTRACT

The purpose of this report is to emphasize the possibility of false-negative biopsies for testicular intraepithelial neoplasia (TIN) in men with high-risk features of testicular cancer and to review the relevant literature. At the Norwegian Radium Hospital patients in this category are offered the chance to undergo a testicular biopsy. A patient is described who had a normal testicular biopsy a decade before presenting with an invasive testicular cancer. Furthermore, this patient is the first case reported with a false-negative biopsy for TIN and a family history of testicular cancer. The evaluation of the biopsies included immunohistochemical staining for c-kit and PIAP (placental-like alkaline phosphatase) in order to diagnose early TIN. Though multifocal or diffuse extension seems to be the most frequent pattern of distribution of TIN, the presented case and another 14 cases from the literature review indicate that the focality of TIN may be a reason for a TIN-negative biopsy.


Subject(s)
Carcinoma in Situ/pathology , Testicular Neoplasms/pathology , Testis/pathology , Adult , Biopsy , False Negative Reactions , Humans , Male
5.
Tidsskr Nor Laegeforen ; 119(4): 521-5, 1999 Feb 10.
Article in Norwegian | MEDLINE | ID: mdl-10081376

ABSTRACT

Glomerular filtration rate (GFR) was measured in two groups of cancer patients. In 20 patients, glomerular filtration rate was measured simultaneously with 51Cr-EDTA, 99mTc-DTPA and the X-ray contrast agent iohexol as markers, and with a complete set of eight blood samples during 24 hours. In a second group of 120 patients, we used 99mTc-DTPA only and tested various simplified methods, based on one or two blood samples. Glomerular filtration rate was also calculated from serum creatinine. There was excellent agreement between the values measured with the three markers, and, in the same group of patients, very good agreement with the results of simplified methods. The larger study carried out with 99mTc-DTPA on the second group of patients, confirmed a very good agreement between methods based on the slope of the plasma curve and a method based on one blood sample only. The correlation was worse between the values obtained by any of the radionuclide methods and those calculated from serum creatinine. The latter method should therefore not be used for determination of renal function.


Subject(s)
Glomerular Filtration Rate , Radioisotope Renography , Radiopharmaceuticals , Technetium Tc 99m Pentetate , Chromium Radioisotopes , Contrast Media , Creatinine/blood , Humans , Iohexol , Kidney Neoplasms/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...