Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Orthop Traumatol Surg Res ; 104(6): 877-882, 2018 10.
Article in English | MEDLINE | ID: mdl-29807189

ABSTRACT

INTRODUCTION: As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. HYPOTHESIS: Carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. MATERIALS AND METHODS: Three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. RESULTS: The mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p<001) for all comparisons except for Hand Innovations vs. Zimmer bending stiffness post fatigue (p=.197). DISCUSSION: The significant higher load to failure of the titanium plate, makes it indicated for patients with higher functional requirements or at higher risk of trauma in the post-operative period. The CFR-PEEK plate showed material-specific disadvantages, represented by little tolerance to plastic deformation, and lower load to failure. LEVEL OF EVIDENCE: N/A.


Subject(s)
Bone Plates , Carbon Fiber , Fracture Fixation, Internal/instrumentation , Stainless Steel , Titanium , Benzophenones , Biomechanical Phenomena , Humans , Ketones , Materials Testing , Osteotomy , Polyethylene Glycols , Polymers , Radius Fractures/surgery
2.
BMC Musculoskelet Disord ; 19(1): 94, 2018 03 27.
Article in English | MEDLINE | ID: mdl-29587695

ABSTRACT

BACKGROUND: The treatment of comminuted radial head fractures can include prosthetic replacement or open reduction and internal fixation. The purpose of this study is to evaluate the results of two different internal fixation systems for Mason type II-III radial head fractures. METHODS: Between 2005 and 2015, 82 patients were treated using pins and 65 patients by mini-screws. The follow-up protocol included: a clinical evaluation 15 days after surgery, and clinical and radiographic evaluations performed at 30 and 60 day intervals, unless any complications were reported by the patient. Over a period of at least 12-months of follow-up, patients were checked and interviewed. Clinical examinations included elbow range of motion (ROM), arm, shoulder and hand Disabilities, (DASH), and the Mayo Elbow Performance Score (MEPS). RESULTS: Sixty-one subjects who had been treated with mini-screws were clinically reviewed at a mean 47.3 ± 35.8 month of follow-up; all patients who had been treated using absorbable pins were evaluated at a mean 82.5 ± 20.6 month of follow-up. No significant statistically differences were observed between the two groups in the mean ROM, DASH, and MEPS scores. Residual pain was reported in 15.8%of the patients treated by pins and 9.2% patients treated by mini-screws. Secondary displacement of fracture fragments was observed in 8.5% patients treated by pins and 1.6% using mini-screws. CONCLUSIONS: Both absorbable pins and mini-screws provided adequate strength and rigidity, allowing good clinical and functional scores at a mid-term follow-up. However, a higher rate of secondary displacement of the fracture fragments was reported among subjects who had been treated using absorbable pins.


Subject(s)
Fracture Fixation, Internal/instrumentation , Radius Fractures/surgery , Absorbable Implants , Adult , Bone Screws , Female , Humans , Male , Middle Aged , Retrospective Studies
3.
Occup Ther Int ; 22(1): 36-42, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25354250

ABSTRACT

The objectives of this study were to determine the effectiveness of a programme of prevention exercises conducted in a corporate environment in poultry industry slaughterers suffering from musculoskeletal disorders. Forty workers, 70% female (mean ± SD age: 44.4 ± 8.4 years) were consecutively, in an alternative way, assigned to one of two groups receiving either set of 10 sessions (experimental or control group). The experimental group followed an exercise programme for a period of five weeks and a protocol of home exercises. The control group performed the exercise protocol only at home. The Roland Morris Disability Questionnaire (RMDQ) and the Oswestry Disability Index (ODI) to measure disability, the Visual Analogue Scale (VAS) score and the Pain Drawing to measure pain were used as outcome evaluations. A significant effect of time interaction (all P <0.001 and; F = 40.673; F = 33.907 and F = 25.447) existed for lumbar VAS, RMDQ and ODI immediately after the intervention (all P < 0.006). No significant group effect or group-by-time interaction was detected for any of them, which suggests that both groups improved in the same way. This study shows that a programme of prevention exercises may have a positive effect in improving musculoskeletal disorders of slaughterhouse workers. Pain decreased in the lumbar region, and there was an almost significant reduction in disability.


Subject(s)
Abattoirs , Exercise Therapy , Low Back Pain/prevention & control , Musculoskeletal Diseases/rehabilitation , Neck Pain/prevention & control , Occupational Diseases/prevention & control , Occupational Therapy , Adult , Animals , Disability Evaluation , Female , Humans , Male , Middle Aged , Pain Measurement , Poultry , Program Evaluation , Treatment Outcome
4.
Arch Orthop Trauma Surg ; 134(8): 1107-14, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24935660

ABSTRACT

INTRODUCTION: The purpose of this retrospective study is to compare the clinical, functional outcome and complications occurrence between tension band wiring (TBW) and plate fixation both for simple and comminuted displaced olecranon fractures. MATERIALS AND METHODS: Between January 2005 and June 2012 (minimum 1-year follow-up), 78 consecutive patients with Mayo type IIA and IIB fractures were treated with the following methods: tension band wire or plate and screws fixation. The primary outcome of this study was the functional outcome, assessed by the following self-administered evaluation scales: the disabilities of the arm, shoulder and hand, and the Mayo Elbow Performance Score. Secondary outcome measures included the assessment of pain level, analysis of passive range of motion, and the occurrence of any early or late complications. RESULTS: Comparing the clinical results between the two groups, at mean 33 months follow-up, no significant differences in the functional and clinical outcome were observed. Complications were reported in 48 and 17 % of cases, following TBW and plate fixation in patients treated for type IIA fractures, and similarly in 40 and 23 % of cases in type IIB fractures, respectively. Hardware removal was more frequently performed in TBW group: 38 versus 17 % for type IIA fractures and 20 versus 6 % for type IIB fractures. CONCLUSIONS: The findings of this study indicate that both with the use of TBW and plate fixation excellent/good clinical outcomes with minimal loss of physical capacity, little pain and disability can be obtained in the majority of patients with simple and comminuted displaced olecranon fractures. Hardware removal was most frequently observed after TBW.


Subject(s)
Fracture Fixation, Internal/methods , Fractures, Comminuted/surgery , Intra-Articular Fractures/surgery , Olecranon Process/injuries , Ulna Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Bone Plates , Bone Wires , Elbow Joint/surgery , Female , Humans , Male , Middle Aged , Recovery of Function , Retrospective Studies , Young Adult
5.
J Orthop Traumatol ; 14(4): 291-7, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23843093

ABSTRACT

BACKGROUND: The treatment of radial neck fractures in children varies according to the displacement, angulation, and skeletal maturity. There is a general agreement that displaced radial neck fractures with more than 30° angulations (Judet type III and IV fractures) should be surgically treated. There are several treatment possibilities for Judet type III and IV fractures including percutaneous pin reduction, elastic stable intramedullary nailing (ESIN), and open reduction with or without internal fixation. In this retrospective study we compared the clinical and radiographical outcomes, and complications following intramedullary versus percutaneous pinning in displaced radial neck fractures in children. MATERIALS AND METHODS: Between 2000 and 2011, 20 patients were treated using closed reduction: in 12 cases we used percutaneous pinning, and in 8 cases we used ESIN. According to Judet classification the two groups were composed as follows: 10 (77 %) type III and 3 (23 %) type IV fractures in the percutaneous pinning group; 4 (57 %) type III, and 3 (43 %) type IV fractures in the ESIN group. RESULTS: After an average of 42 months, excellent results in Mayo elbow performance scores (MEPS) were obtained in 71 and 69 % of ESIN and percutaneous pinning groups respectively, with good results in the remaining cases apart from one fair case (8 %) in the percutaneous pinning group. After a radiological evaluation, all fractures healed in excellent or good alignment. When comparing the two groups, the subjects treated with the ESIN technique had higher range of motion (ROM) in flexion, extension and pronation. No patients developed complications, except three cases of asymptomatic enlargements of the radial head, reported only in the percutaneous pinning group. CONCLUSION: In this research the clinical outcome, assessed with the MEPS, and the radiological alignment, were comparable between the subjects that were treated with percutaneous pinning and those with ESIN techniques; whereas the ESIN technique demonstrated higher ROM in flexion, extension and pronation. The ESIN technique seems to be the ideal approach both for the higher ROM values and for the absence of complications.


Subject(s)
Fracture Fixation, Internal/methods , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Adolescent , Arthralgia , Bone Nails , Child , Elasticity , Female , Follow-Up Studies , Humans , Male , Radiography , Range of Motion, Articular , Retrospective Studies , Treatment Outcome
6.
Phys Ther ; 93(8): 1026-36, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23559524

ABSTRACT

BACKGROUND: Given the prevalence of chronic nonspecific neck pain (CNSNP) internationally, attention has increasingly been paid in recent years to evaluating the efficacy of therapeutic exercise (TE) in the management of this condition. PURPOSE: The purpose of this study was to conduct a current review of randomized controlled trials concerning the effect of TE on pain and disability among people with CNSNP, perform a meta-analysis, and summarize current understanding. DATA SOURCES: Data were obtained from MEDLINE, Cumulative Index to Nursing and Allied Health Literature (CINAHL), EMBASE, Physiotherapy Evidence Database (PEDro), and Cochrane Central Register of Controlled Trials (CENTRAL) databases from their inception to August 2012. Reference lists of relevant literature reviews also were tracked. STUDY SELECTION: All published randomized trials without any restriction regarding time of publication or language were considered for inclusion. Study participants had to be symptomatic adults with only CNSNP. DATA EXTRACTION: Two reviewers independently selected the studies, conducted the quality assessment, and extracted the results. Data were pooled in a meta-analysis using a random-effects model. DATA SYNTHESIS: Seven studies met the inclusion criteria. Therapeutic exercise proved to have medium and significant short-term and intermediate-term effects on pain (g=-0.53, 95% confidence interval [CI]=-0.86 to -0.20, and g=-0.45, 95% CI=-0.82 to -0.07, respectively) and medium but not significant short-term and intermediate-term effects on disability (g=-0.39, 95% CI=-0.86 to 0.07, and g=-0.46, 95% CI=-1.00 to -0.08, respectively). LIMITATIONS: Only one study investigated the effect of TE on pain and disability at follow-up longer than 6 months after intervention. CONCLUSIONS: Consistent with other reviews, the results support the use of TE in the management of CNSNP. In particular, a significant overall effect size was found supporting TE for its effect on pain in both the short and intermediate terms.


Subject(s)
Disabled Persons/rehabilitation , Exercise Therapy/methods , Neck Pain/rehabilitation , Physical Therapy Modalities , Chronic Disease , Disease Management , Humans , Pain Management/methods , Quality of Life , Randomized Controlled Trials as Topic
7.
Joint Bone Spine ; 79(2): 176-85, 2012 Mar.
Article in English | MEDLINE | ID: mdl-21565540

ABSTRACT

OBJECTIVES: In the past decade many countries around the world have produced clinical practice guidelines to assist practitioners in providing a care that is aligned with the best evidence. The aim of this study was to present and compare the most established evidence-based recommendations for the management of chronic nonspecific low back pain in primary care derived from current high-quality international guidelines. METHODS: Guidelines published or updated since 2002 were selected by searching PubMed, CINAHL, EMBASE, guidelines databases, and the World Wide Web. The methodological quality of the guidelines was assessed by three authors independently, using the Appraisal of Guidelines for Research and Evaluation (AGREE) Instrument. Guideline recommendations were synthesized into diagnostic and therapeutic approaches that were supported by strong, moderate or weak evidence. RESULTS: Thirteen guidelines were included. In general, the quality was satisfactory. Guidelines had highest scores on clarity and presentation and scope and purpose domains, and lowest scores on applicability. There was a strong consensus among all the guidelines particularly regarding the use of diagnostic triage and the assessment of prognostic factors. Consistent therapeutic recommendations were information, exercise therapy, multidisciplinary treatment, and combined physical and psychological interventions. CONCLUSION: Compared to previous assessments, the average quality of the guidelines dealing with chronic low back pain has improved. Furthermore, all guidelines are increasingly aligning in providing therapeutic recommendations that are clearly differentiated from those formulated for acute pain. However, there is still a need for improving quality and generating new evidence for this particular condition.


Subject(s)
Disease Management , Low Back Pain/therapy , Practice Guidelines as Topic/standards , Primary Health Care , Chronic Disease , Evidence-Based Practice , Humans , Quality Assurance, Health Care , Reproducibility of Results
8.
J Manipulative Physiol Ther ; 34(4): 231-8, 2011 May.
Article in English | MEDLINE | ID: mdl-21621724

ABSTRACT

OBJECTIVE: The aim of this retrospective study was to assess validity of the straight-leg raise (SLR) test using magnetic resonance imaging (MRI) results as a reference standard in a group of patients with L4-L5 and L5-S1 lumbar-herniated disks and sciatic pain. The relationship between diagnostic accuracy of this test, age classes, and grade of lumbar disk displacement was investigated. METHODS: The charts of 2352 patients with sciatic pain with/without lumbar pain were examined. Results of the SLR were then compared with previous spinal MRI. A 2 × 2 contingency table was created, and analysis of sensitivity, specificity, positive and negative predictive values, diagnostic odds ratio, likelihood ratio (LR), and receiver operating characteristic (ROC) curve was carried out. Homogeneous age classes were created to compare them statistically. RESULTS: Magnetic resonance imaging findings showed lumbar disk herniation (LDH) in 1305 patients. Of these subjects, 741 were positive on SLR testing. Sensitivity was 0.36, whereas specificity was 0.74. Positive and negative predictive values were 0.69 and 0.52, respectively. Positive LR was 1.38, and negative LR was 0.87. Diagnostic odds ratio was 1.59, and ROC analysis showed an area under the curve (AUC) of 0.596. The AUC decreased from 0.730 in the 16- to 25-year subgroup to 0.515 in the 76- to 85-year subgroup. Similar results were obtained in subjects with LDH and nerve root compression. CONCLUSIONS: Our results indicate low accuracy of the SLR in diagnosis of LDH if compared with MRI results. The discriminative power of the SLR seemed to decrease as age increased; thus, positive and negative results may be less conclusive in older patients.


Subject(s)
Intervertebral Disc Displacement/diagnosis , Low Back Pain/diagnosis , Lumbar Vertebrae , Magnetic Resonance Imaging , Sciatica/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Intervertebral Disc Displacement/complications , Leg , Low Back Pain/complications , Male , Middle Aged , Reference Standards , Reproducibility of Results , Retrospective Studies , Sciatica/complications , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...