Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 14(4)2023 Apr 20.
Article in English | MEDLINE | ID: mdl-37421117

ABSTRACT

The authors present in this study the development of a novel method for creating stretchable electronics from dual-layer flex printed circuit boards (flex-PCBs) as a platform for soft robotic sensor arrays (SRSAs) for cardiac voltage mapping applications. There is a crucial need for devices that utilize multiple sensors and provide high performance signal acquisition for cardiac mapping. Previously, our group demonstrated how single-layer flex-PCB can be postprocessed to create a stretchable electronic sensing array. In this work, a detailed fabrication process for creating a dual-layer multielectrode flex-PCB SRSA is presented, along with relevant parameters to achieve optimal postprocessing with a laser cutter. The dual-layer flex-PCB SRSA's ability to acquire electrical signals is demonstrated both in vitro as well as in vivo on a Leporine cardiac surface. These SRSAs could be extended into full-chamber cardiac mapping catheter applications. Our results show a significant contribution towards the scalable use of dual-layer flex-PCB for stretchable electronics.

2.
Front Cardiovasc Med ; 9: 909680, 2022.
Article in English | MEDLINE | ID: mdl-35845036

ABSTRACT

Objective: To develop a novel in vitro method for evaluating coronary artery ischemia using a combination of non-invasive coronary CT angiograms (CCTA) and 3D printing (FFR3D). Methods: Twenty eight patients with varying degrees of coronary artery disease who underwent non-invasive CCTA scans and invasive fractional flow reserve (FFR) of their epicardial coronary arteries were included in this study. Coronary arteries were segmented and reconstructed from CCTA scans using Mimics (Materialize). The segmented models were then 3D printed using a Carbon M1 3D printer with urethane methacrylate (UMA) family of rigid resins. Physiological coronary circulation was modeled in vitro as flow-dependent stenosis resistance in series with variable downstream resistance. A range of physiological flow rates (Q) were applied using a peristaltic steady flow pump and titrated with a flow sensor. The pressure drop (ΔP) and the pressure ratio (Pd/Pa) were assessed for patient-specific aortic pressure (Pa) and differing flow rates (Q) to evaluate FFR3D using the 3D printed model. Results: There was a good positive correlation (r = 0.87, p < 0.0001) between FFR3D and invasive FFR. Bland-Altman analysis revealed a good concordance between the FFR3D and invasive FFR values with a mean bias of 0.02 (limits of agreement: -0.14 to 0.18; p = 0.2). Conclusions: 3D printed patient-specific models can be used in a non-invasive in vitro environment to quantify coronary artery ischemia with good correlation and concordance to that of invasive FFR.

3.
Sci Adv ; 6(46)2020 11.
Article in English | MEDLINE | ID: mdl-33188028

ABSTRACT

Devices that perform cardiac mapping and ablation to treat atrial fibrillation provide an effective means of treatment. Current devices, however, have limitations that either require tedious point-by-point mapping of a cardiac chamber or have limited ability to conform to the complex anatomy of a patient's cardiac chamber. In this work, a detailed, scalable, and manufacturable technique is reported for fabrication of a multielectrode, soft robotic sensor array. These devices exhibit high conformability (~85 to 90%) and are equipped with an array of stretchable electronic sensors for voltage mapping. The form factor of the device is intended to match that of the entire left atrium and has a hydraulically actuated soft robotic structure whose profile facilitates deployment from a 13.5-Fr catheter. We anticipate that the methods described in this paper will serve a new generation of conformable medical devices that leverage the unique characteristics of stretchable electronics and soft robotics.

4.
Adv Healthc Mater ; 9(4): e1900951, 2020 02.
Article in English | MEDLINE | ID: mdl-31945275

ABSTRACT

This paper presents the design, fabrication, and test results for a novel basket catheter that utilizes soft robotic technology, which can conform to complex patient anatomy. Two designs of basket-shaped balloons in three sizes are fabricated based on a CO2 laser cutting method from thin (<50 µm) thermoplastic polyurethane. The balloons are deployed in four soft-material 3D printed left atria, whose geometries are based on volume rendered segmentation of cardiac computed tomography (CT) scans. The coverage and conformability to the realistic patient anatomies is tracked with the small patches of pH paper that indicate, via a color change, contact with a basic solution that lined the 3D printed atriums. The conformability of these inflatable basket catheters is demonstrated as high as (85%) for the optimized design. To visualize the balloon's performance, microCT images of balloons deployed in 3D printed models are shown. These images show the ability of the balloons to adapt to complex patient anatomy and do not exhibit any spline bunching or other deleterious mechanical behavior. This platform has the potential to be coupled with electrical sensors for simultaneous multisensor mapping of atrial fibrillation and other cardiac arrhythmias.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Robotics , Atrial Fibrillation/surgery , Catheters , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans
5.
J Vis Exp ; (153)2019 11 08.
Article in English | MEDLINE | ID: mdl-31762456

ABSTRACT

This protocol describes a method for rapid manufacturing of soft pneumatic actuators and robots with an ultrathin form factor using a heat press and a laser cutter machine. The method starts with the lamination of thermoplastic polyurethane (TPU) sheets using a heat press for 10 min at the temperature of ~93 °C. Next, the parameters of the laser cutter machine are optimized to produce a rectangular balloon with maximum burst pressure. Using the optimized parameters, the soft actuators are laser cut/welded three times sequentially. Next, a dispensing needle is attached to the actuator, allowing it to be inflated. The effect of geometrical parameters on the deflection of the actuator are studied systematically by varying the channel width and length. Finally, the performance of the actuator is characterized using an optical camera and a fluid dispenser. Conventional fabrication methods of soft pneumatic actuators based on silicone molding are time consuming (several hours). They also result in strong but bulky actuators, which limits the actuator's applications. Moreover, microfabrication of thin pneumatic actuators is both time-consuming and expensive. The proposed manufacturing method in the current work resolves these issues by introducing a fast, simple, and cost-effective fabrication method of ultrathin pneumatic actuators.


Subject(s)
Robotics/instrumentation , Equipment Design , Lasers , Polyurethanes/chemistry
6.
Micromachines (Basel) ; 10(10)2019 Oct 16.
Article in English | MEDLINE | ID: mdl-31623246

ABSTRACT

Micropatterning is often used to engineer the surface properties of objects because it allows the enhancement or modification of specific functionalities without modification of the bulk material properties. Microneedle arrays have been explored in the past for drug delivery and enhancement of tissue anchoring; however, conventional methods are primarily limited to thick, planar substrates. Here, we demonstrate a method for the fabrication of microneedle arrays on thin flexible polyurethane substrates. These thin-film microneedle arrays can be used to fabricate balloons and other inflatable objects. In addition, these thin-filmed microneedles can be transferred, using thermal forming processes, to more complex 3D objects on which it would otherwise be difficult to directly pattern microneedles. This function is especially useful for medical devices, which require effective tissue anchorage but are a challenging target for micropatterning due to their 3D nonplanar shape, large size, and the complexity of the required micropatterns. Ultrathin flexible thermoplastic polyurethane microneedle arrays were fabricated from a polydimethylsiloxane (PDMS) mold. The technique was applied onto the nonplanar surface of rapidly prototyped soft robotic implantable polyurethane devices. We found that a microneedle-patterned surface can increase the anchorage of the device to a tissue by more than twofold. In summary, our soft lithographic patterning method can rapidly and inexpensively generate thin-film microneedle surfaces that can be used to produce balloons or enhance the properties of other 3D objects and devices.

7.
PLoS One ; 14(7): e0219174, 2019.
Article in English | MEDLINE | ID: mdl-31260497

ABSTRACT

The primary mode of visualization during transcatheter procedures for structrural heart disease is fluoroscopy, which suffers from low contrast and lacks any depth perception, thus limiting the ability of an interventionalist to position a catheter accurately. This paper describes a new image guidance system by utilizing augmented reality to provide a 3D visual environment and quantitative feedback of the catheter's position within the heart of the patient. The real-time 3D position of the catheter is acquired via two fluoroscopic images taken at different angles, and a patient-specific 3D heart rendering is produced pre-operatively from a CT scan. The spine acts as a fiduciary land marker, allowing the position and orientation of the catheter within the heart to be fully registered. The automated registration method is based on Fourier transformation, and has a high success rate (100%), low registration error (0.42 mm), and clinically acceptable computational cost (1.22 second). The 3D renderings are displayed and updated on the augmented reality device (i.e., Microsoft HoloLens), which can provide pre-set views of various angles of the heart using voice-command. This new image-guidance system with augmented reality provides a better visualization to interventionalists and potentially assists them in understanding of complicated cases. Furthermore, this system coupled with the developed 3D printed models can serve as a training tool for the next generation of cardiac interventionalists.


Subject(s)
Augmented Reality , Cardiac Catheterization/methods , Cardiac Surgical Procedures/methods , Imaging, Three-Dimensional/methods , Surgery, Computer-Assisted/methods , Cardiac Catheterization/instrumentation , Cardiac Surgical Procedures/instrumentation , Catheters , Fiducial Markers , Fluoroscopy/instrumentation , Fluoroscopy/methods , Fourier Analysis , Heart/anatomy & histology , Heart/diagnostic imaging , Humans , Imaging, Three-Dimensional/instrumentation , Models, Anatomic , Patient Care Planning , Phantoms, Imaging , Preoperative Care/methods , Printing, Three-Dimensional , Spine/diagnostic imaging , Surgery, Computer-Assisted/instrumentation , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...