Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Pers Med ; 13(10)2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37888093

ABSTRACT

Respiratory infections are frequent and life-threatening complications of surgery. This study aimed to evaluate the clinical, microbiological and treatment characteristics of severe postoperative pneumonia (POP) and tracheobronchitis (POT) in a large series of patients. This single-center, prospective observational cohort study included patients with POP or POT requiring intensive care unit admission in the past 10 years. We recorded demographic, clinical, microbiological and therapeutic data. A total of 207 patients were included, and 152 (73%) were men. The mean (SD) age was 70 (13) years and the mean (SD) ARISCAT score was 46 (19). Ventilator-associated pneumonia was reported in 21 patients (10%), hospital-acquired pneumonia was reported in 132 (64%) and tracheobronchitis was reported in 54 (26%). The mean (SD) number of days from surgery to POP/POT diagnosis was 6 (4). The mean (SD) SOFA score was 5 (3). Respiratory microbiological sampling was performed in 201 patients (97%). A total of 177 organisms were cultured in 130 (63%) patients, with a high proportion of Gram-negative and multi-drug resistant (MDR) bacteria (20%). The most common empirical antibiotic therapy was a triple-drug regimen covering MDR Gram-negative bacteria and MRSA. In conclusion, surgical patients are a high-risk population with a high proportion of early onset severe POP/POT and nosocomial bacteria isolation.

2.
Antibiotics (Basel) ; 10(6)2021 Jun 03.
Article in English | MEDLINE | ID: mdl-34204943

ABSTRACT

Background: Pathophysiological changes such as extreme body weights in critically ill patients with severe infections may alter the pharmacokinetics (PK) of antimicrobials, leading to treatment failure or toxicity. There are almost no PK data on meropenem in critically ill patients with low body weight (LwBW) and therefore information is lacking on the most appropriate dosing regimens, especially when administered by extended infusion. Objectives: To assess if the current administered doses of meropenem could lead to supratherapeutic concentrations in LwBW patients and to identify the factors independently associated with overexposure. Methods: A matched case-control 1:1 study of surgical critically ill patients treated with meropenem administered by extended or continuous infusion and undergoing therapeutic drug monitoring was conducted. Cases (patients with LwBW (body mass index (BMI) < 18.5 kg/m2)) were matched with normal body weight controls (NBW) (patients with BMI ≥ 18.5 kg/m2 and ≤30 kg/m2)) by age, gender, baseline renal function and severity status (APACHE II score). A 100% fT > MIC was considered an optimal pharmacokinetic/pharmacodynamic (PK/PD) target and 100% fT > 10 × MIC as supratherapeutic exposure. Results: Thirty-six patients (18 cases and 18 controls) were included (median (range) age, 57.5 (26-75) years; 20 (55.6% male)). Meropenem was administered by 6 h (extended) or 8 h (continuous) infusion at a median (range) daily dose of 5 (1-6) g/day. Similar median meropenem trough plasma concentrations (Cmin,ss), measured pre-dose on day three to four of treatment) were observed in the two groups (19.9 (22.2) mg/L vs 22.4 (25.8) mg/L, p > 0.999). No differences in the proportion of patients with an optimal or a supratherapeutic PKPD target between cases and controls were observed. A baseline estimated glomerular filtration rate (eGFR) < 90 mL/min was the only factor independently associated with a supratherapeutic PK/PD target. Conclusions: LwBW seems not to be a risk factor for achieving a supratherapeutic PK/PD target in critically ill patients receiving meropenem at standard doses by extended or continuous infusion.

3.
Crit Care ; 24(1): 55, 2020 02 17.
Article in English | MEDLINE | ID: mdl-32066497

ABSTRACT

BACKGROUND: Optimal antimicrobial drug exposure in the lung is required for successful treatment outcomes for nosocomial pneumonia. Little is known about the intrapulmonary pharmacokinetics (PK) of meropenem when administered by continuous infusion (CI). The aim of this study was to evaluate the PK of two dosages of meropenem (3 g vs 6 g/day by CI) in the plasma and epithelial lining fluid (ELF) in critically ill patients with nosocomial pneumonia. METHODS: Thirty-one patients (81% male, median (IQR) age 72 (22) years) were enrolled in a prospective, randomized, clinical trial. Sixteen patients received 1 g/8 h and 15 2 g/8 h by CI (8 h infusion). Plasma and ELF meropenem concentrations were modeled using a population methodology, and Monte Carlo simulations were performed to estimate the probability of attaining (PTA) a free ELF concentration of 50% of time above MIC (50% fT>MIC), which results in logarithmic killing and the suppression of resistance in experimental models of pneumonia. RESULTS: The median (IQR) of meropenem AUC0-24 h in the plasma and ELF was 287.6 (190.2) and 84.1 (78.8) mg h/L in the 1 g/8 h group vs 448.1 (231.8) and 163.0 (201.8) mg h/L in the 2 g/8 h group, respectively. The penetration ratio was approximately 30% and was comparable between the dosage groups. In the Monte Carlo simulations, only the highest approved dose of meropenem of 2 g/8 h by CI allowed to achieve an optimal PTA for all isolates with a MIC < 4 mg/L. CONCLUSIONS: An increase in the dose of meropenem administered by CI achieved a higher exposure in the plasma and ELF. The use of the highest licensed dose of 6 g/day may be necessary to achieve an optimal coverage in ELF for all susceptible isolates (MIC ≤ 2 mg/L) in patients with conserved renal function. An alternative therapy should be considered when the presence of microorganisms with a MIC greater than 2 mg/L is suspected. TRIAL REGISTRATION: The trial was registered in the European Union Drug Regulating Authorities Clinical Trials Database (EudraCT-no. 2016-002796-10). Registered on 27 December 2016.


Subject(s)
Anti-Bacterial Agents , Cross Infection , Healthcare-Associated Pneumonia , Meropenem , Aged , Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacokinetics , Cross Infection/drug therapy , Female , Healthcare-Associated Pneumonia/drug therapy , Humans , Infusions, Intravenous , Male , Meropenem/administration & dosage , Meropenem/pharmacokinetics , Middle Aged , Prospective Studies
4.
J Antimicrob Chemother ; 74(11): 3268-3273, 2019 11 01.
Article in English | MEDLINE | ID: mdl-31495877

ABSTRACT

OBJECTIVES: To assess the pharmacokinetics of formed colistin in plasma and the safety of two different high doses of colistimethate sodium administered via nebulization in critically ill surgical patients with hospital-acquired pneumonia (HAP) or ventilator-associated pneumonia (VAP). PATIENTS AND METHODS: Formed colistin plasma concentrations were measured in critically ill surgical patients with pneumonia treated with two different doses of nebulized colistimethate sodium (3 MIU/8 h versus 5 MIU/8 h). Adverse events possibly related to nebulized colistimethate sodium were recorded. RESULTS: Twenty-seven patients (15 in the 3 MIU/8 h group and 12 in the 5 MIU/8 h group) were included. Colistin plasma concentrations were unquantifiable (<0.1 mg/L) in eight (53.3%) patients in the 3 MIU/8 h group and in seven patients (58.3%) in the 5 MIU/8 h group. Median (IQR) quantifiable colistin plasma concentrations before nebulization and at 1, 4 and 8 h were 0.17 (0.12-0.33), 0.20 (0.11-0.24), 0.17 (0.12-0.23) and 0.17 (0.11-0.32) mg/L, respectively, in the 3 MIU/8 h group and 0.20 (0.11-0.35), 0.24 (0.12-0.44), 0.24 (0.10-0.49) and 0.23 (0.11-0.44) mg/L, respectively, in the 5 MIU/8 h group, with no differences between the two groups at any time. Renal impairment during nebulized treatment was observed in three patients in each group, but was unlikely to be related to colistimethate sodium treatment. Nebulized colistimethate sodium therapy was well tolerated and no bronchospasms or neurotoxicity events were observed. CONCLUSIONS: In this limited observational case series of critically ill patients with HAP or VAP treated with high doses of nebulized colistimethate sodium, systemic exposure was minimal and the treatment was well tolerated.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacokinetics , Colistin/analogs & derivatives , Pneumonia, Bacterial/drug therapy , Pneumonia, Ventilator-Associated/drug therapy , Administration, Inhalation , Aged , Aged, 80 and over , Anti-Bacterial Agents/blood , Colistin/administration & dosage , Colistin/blood , Colistin/pharmacokinetics , Critical Illness , Female , Humans , Male , Middle Aged , Nebulizers and Vaporizers , Pneumonia, Ventilator-Associated/microbiology , Prospective Studies
5.
J Neurosurg Anesthesiol ; 22(3): 240-6, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20479667

ABSTRACT

BACKGROUND: During neuroendoscopic procedures, pressure inside the neuroendoscope (PIN) monitored through the irrigation channel correlates with the occurrence of postoperative complications. Our aim was to analyze the reliability of PIN measurement as a surrogate for intracranial pressure (ICP) by comparing PIN with simultaneously epidural ICP measurement as the standard. METHODS: Seventeen consecutive patients undergoing neuroendoscopy were studied prospectively. Type and length of procedure and PIN and epidural ICP values during neuroendoscopy were recorded. Lin's concordance coefficient and Bland-Altman analysis of agreement were used to assess correspondence between the 2 systems. RESULTS: A consistent relation between PIN and epidural ICP waveforms was observed during neuroendoscopic navigation. A strong Pearson correlation between PIN and epidural ICP data were found in 15 patients. Epidural ICP values were systematically higher than PIN values in 15 patients. Lin concordance coefficients showed moderate global agreement between the 2 methods, at 0.58 (95% confidence interval, 0.577-0.592). In 6 cases (35.2%) concordance was good according to this analysis, in 7 cases (41.2%) agreement was moderate/fair, and in 4 cases (23.5%) agreement was poor. The Bland-Altman analysis of patient data showed good agreement between the PIN and epidural ICP measurements for most patients, although discrepancies were greater at higher ICP values for 11 patients. Bland-Altman analysis of the complete dataset, after the normalization of individual's measurements, showed good overall agreement. CONCLUSIONS: PIN measurement seems useful for evaluating ICP changes related to neuroendoscopic procedures and seems to be more consistent than epidural ICP at high pressures.


Subject(s)
Endoscopy , Epidural Space/physiology , Intracranial Pressure/physiology , Neuroendoscopy , Neurosurgical Procedures , Adult , Aged , Anesthesia, General , Female , Humans , Linear Models , Male , Middle Aged , Neuroendoscopes , Prospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...