Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Neurocirugia (Astur) ; 18(6): 478-84, 2007 Dec.
Article in Spanish | MEDLINE | ID: mdl-18094906

ABSTRACT

OBJECTIVE: A computerized version of the Schaltenbrand and Wahren's stereotactic brain atlas for image-guided functional neurosurgery planning has been developed and integrated into our PC-based planning system. METHODS: The SW atlas plates were digitized, contoured and labeled for both hemispheres. The computerized atlas may be interactively registered with patient's data using linear and non-linear transformation. The implemented computational tools and applications are presented. RESULTS: Our computer system permits navigation through original or reconstructed slices, multiple-views synchronization and zoom to improve the localization of the commisures and the surgical targets, likewise the optimum path selection. Atlas position in the target's region can be interactively actualized and lesion's position and volume may be simulated. CONCLUSIONS: Its benefits of this approach include increased accuracy of target definition, decreased the number of electrode tracts and for instance the time of the surgery, and reduced surgical complications.


Subject(s)
Brain Mapping/instrumentation , Brain/anatomy & histology , Brain/surgery , Neurosurgical Procedures/methods , Surgery, Computer-Assisted/instrumentation , Humans
2.
Neurocirugia (Astur) ; 18(6)Dec. 2007. ilus
Article in Spanish | CUMED | ID: cum-39827

ABSTRACT

Objetivo. Desarrollar un atlas estereotáctico computarizadode Schaltenbrand y Wahren para la planificación de neurocirugías funcionales guiadas por imágenes.Este atlas está integrado al sistema de planificación STASSIS, desarrollado para computadoras personales.Métodos. Los cortes originales del atlas fueron digitalizados y se trazaron los contornos para ambos hemisferios. El corregistro del atlas con las imágenes del paciente se realiza mediante transformaciones rígidas y no rígidas. Se presentan las herramientas computacionales implementadas y sus aplicaciones durante el procedimiento quirúrgico.Resultados. El sistema permite la navegación continuatanto a través de los cortes originales como de las reconstrucciones, la sincronización de múltiples vistasy el uso de ampliaciones, lo que permite incrementar la exactitud en la localización de las comisuras y los blancos quirúrgicos, así como la selección óptima de las trayectorias.Los contornos del atlas se pueden ajustar a la anatomía del paciente. La posición del atlas en la regióndel blanco se puede actualizar de forma interactiva y simular la posición y volumen de las lesiones.Conclusiones. Los beneficios de esta metodología incluyen la mejora en la exactitud de la localización del primerblanco quirúrgico, disminución del número de trayectos con los electrodos y, por tanto, del tiempo de la cirugía, y lareducción de las posibles complicaciones quirúrgicas(AU)


OBJECTIVE. A computerized version of the Schaltenbrand and Wahren's stereotactic brain atlas for image-guided functional neurosurgery planning has been developed and integrated into our PC-based planning system. METHODS. The SW atlas plates were digitized, contoured and labeled for both hemispheres. The computerized atlas may be interactively registered with patient's data using linear and non-linear transformation. The implemented computational tools and applications are presented. RESULTS. Our computer system permits navigation through original or reconstructed slices, multiple-views synchronization and zoom to improve the localization of the commisures and the surgical targets, likewise the optimum path selection. Atlas position in the target's region can be interactively actualized and lesion's position and volume may be simulated. CONCLUSIONS. Its benefits of this approach include increased accuracy of target definition, decreased the number of electrode tracts and for instance the time of the surgery, and reduced surgical complications(AU)


Subject(s)
Cerebrum/anatomy & histology , Cerebrum/surgery , Brain Mapping/instrumentation , Neurosurgical Procedures/methods , Surgery, Computer-Assisted/instrumentation
3.
Neurocir. - Soc. Luso-Esp. Neurocir ; 18(6): 478-484, nov.-dic. 2007. ilus
Article in Es | IBECS | ID: ibc-70337

ABSTRACT

Objetivo. Desarrollar un atlas estereotáctico computarizado de Schaltenbrand y Wahren para la planificación de neurocirugías funcionales guiadas por imágenes. Este atlas está integrado al sistema de planificación STASSIS, desarrollado para computadoras personales. Métodos. Los cortes originales del atlas fueron digitalizados y se trazaron los contornos para ambos hemisferios. El corregistro del atlas con las imágenes del paciente se realiza mediante transformaciones rígidas y no rígidas. Se presentan las herramientas computacionales implementadas y sus aplicaciones durante el procedimiento quirúrgico. Resultados. El sistema permite la navegación continua tanto a través de los cortes originales como de las reconstrucciones, la sincronización de múltiples vistas y el uso de ampliaciones, lo que permite incrementar la exactitud en la localización de las comisuras y los blancos quirúrgicos, así como la selección óptima de las trayectorias. Los contornos del atlas se pueden ajustar a la anatomía del paciente. La posición del atlas en la región el blanco se puede actualizar de forma interactiva y simular la posición y volumen de las lesiones. Conclusiones. Los beneficios de esta metodología incluyen la mejora en la exactitud de la localización del primer blanco quirúrgico, disminución del número de trayectos con los electrodos y, por tanto, del tiempo de la cirugía, y la reducción de las posibles complicaciones quirúrgicas


Objective. A computerized version of the Schaltenbrand and Wahren's stereotactic brain atlas for image-guided functional neurosurgery planning has been developed and integrated into our PC-based planning system. Methods. The SW atlas plates were digitized, contoured and labeled for both hemispheres. The computerized atlas may be interactively registered with patient's data using linear and non-linear transformation. The implemented computational tools and applications are presented. Results. Our computer system permits navigation through original or reconstructed slices, multiple-views synchronization and zoom to improve the localization of the commissures and the surgical targets, likewise the optimum path selection. Atlas position in the target’s region can be interactively actualized and lesion’s position and volume may be simulated. Conclusions. Its benefits of this approach include increased accuracy of target definition, decreased the number of electrode tracts and for instance the time of the surgery, and reduced surgical complications


Subject(s)
Humans , Cerebrum/surgery , Cerebrum/anatomy & histology , Brain Mapping/instrumentation , Neurosurgical Procedures/methods , Surgery, Computer-Assisted/instrumentation
4.
Rev Neurol ; 37(5): 404-12, 2003.
Article in Spanish | MEDLINE | ID: mdl-14533086

ABSTRACT

AIM: The effectiveness of anatomic localization of the subthalamic nucleus (EAL) was assessed and the mapping method is described here. The symmetry of contralateral nuclei (SCN) was analyzed on 11 parkinsonian patients submitted to bilateral subthalamotomy with ablative lesioning. PATIENTS AND METHODS: To assess EAL the percentage so much of first trajectory (p1) as the total of trajectories (pt) that hit the target and the rest of subthalamic nucleus average distance (d) was calculated. The anatomic localization error (epsilon) is determined as a difference between first trajectory coordinates with those of medial determined nucleus point, through electrophysiological data as to the statistical significance of this error. SCN is analyzed by contrasting equality hypothesis at the nucleus maximum height alongside a trajectory, average electrophysiological position center and spatial distribution of all intranuclear recordings found in each hemisphere in all patients. RESULTS: The pi, pt and d obtained values were 86.36%, 86.13% and 1.41 +/- 1.01 mm respectively. The epsilon value was greater in anteroposterior direction of 1.11 +/- 0.83 mm without statistical significance. The average number of recorded trajectories for the first procedure was 6.45 and 6 for the second. The asymmetry of contralateral nucleus was not significant. CONCLUSIONS: An indirect method with CT brain images and a new electrophysiological mapping method with a multiunitary recording for first and second nucleus is safe enough and it yields a high effectiveness in anatomofunctional nucleus localization. The nucleus of a same patient are symmetrical. There is little space variability among patient non related to the differences in the intercommissural distance.


Subject(s)
Brain Mapping , Stereotaxic Techniques , Subthalamic Nucleus/anatomy & histology , Aged , Electric Stimulation Therapy , Electrodes, Implanted , Female , Humans , Male , Middle Aged , Parkinson Disease/pathology , Parkinson Disease/surgery , Subthalamic Nucleus/surgery
5.
Rev. neurol. (Ed. impr.) ; 37(5): 404-412, 1 sept., 2003. graf, tab, ilus
Article in Es | IBECS | ID: ibc-28162

ABSTRACT

Objetivos. Se evalúa la efectividad de localización anatómica (ELAN) bilateral del núcleo subtalámico (NST), se describe el método de cartografiado electrofisiológico y se analiza la simetría de los núcleos contralaterales (SC) en 11 pacientes con enfermedad de Parkinson, sometidos a subtalamotomía bilateral. Pacientes y métodos. Para evaluar la ELAN se calcula el porcentaje tanto de los primeros trayectos (p1) como del total de trayectos (pt) que hicieron blanco, así como la distancia promedio (d) del resto al NST. Se define el error de localización anatómica ( Epsilon ) como la diferencia entre las coordenadas del primer trayecto y las del punto medio del núcleo, determinado por la información electrofisiológica, así como la significación estadística de este error. La SC se analiza con el contraste de la hipótesis de igualdad en la máxima altura del núcleo a lo largo de un trayecto, la posición promedio del centro electrofisiológico y la distribución espacial de todos los registros intranucleares en todos los pacientes encontrado en cada hemisferio. Resultados. Los valores de p1, pt y d obtenidos fueron 86,36 por ciento, 86,13 por ciento y 1,41 ñ 1,01 mm, respectivamente. El valor de fue mayor en la dirección anteroposterior (1,11 ñ 0,83 mm), aunque sin significación estadística (test ANOVA de Kruskal Wallis para la mediana y test de Wilcoxon para muestras apareadas; p = 0,05). El número promedio de trayectos de registros para el primer proceder fue 6,45, y para el segundo, 6. La asimetría de los núcleos contralaterales no fue significativa (test ANOVA de Kruskal Wallis para la mediana y test de Wilcoxon para muestras apareadas; p = 0,05). Conclusiones. Un método indirecto con imágenes de TAC y un novedoso método de cartografiado electrofisiológico con registro multiunitario, para el primer y el segundo núcleo, son seguros y brindan una alta efectividad en la localización anatomofuncional del núcleo. Los núcleos de un mismo paciente son simétricos. Se observó poca variabilidad espacial entre pacientes, no relacionada con las diferencias en la distancia intercomisural (AU)


Aim. The effectiveness of anatomic localization of the subthalamic nucleus (EAL) was assessed and the mapping method is described here. The symmetry of contralateral nuclei (SCN) was analyzed on 11 parkinsonian patients submitted to bilateral subthalamotomy with ablative lesioning. Patients and methods. To assess EAL the percentage so much of first trajectory (p1) as the total of trajectories (pt) that hit the target and the rest of subthalamic nucleus average distance (d) was calculated. The anatomic localization error (ε) is determined as a difference between first trajectory coordinates with those of medial determined nucleus point, through electrophysiological data as to the statistical significance of this error. SCN is analyzed by contrasting equality hypothesis at the nucleus maximum height alongside a trajectory, average electrophysiological position center and spatial distribution of all intranuclear recordings found in each hemisphere in all patients. Results. The pi, pt and d obtained values were 86.36%, 86.13% and 1.41±1.01 mm respectively. The ε value was greater in anteroposterior direction of 1.11±0.83mm without statistical significance. The average number of recorded trajectories for the first procedure was 6.45 and 6 for the second. The asymmetry of contralateral nucleus was not significant. Conclusions. An indirect method with CT brain images and a new electrophysiological mapping method with a multiunitary recording for first and second nucleus is safe enough and it yields a high effectiveness in anatomofunctional nucleus localization. The nucleus of a same patient are symmetrical. There is little space variability among patient non related to the differences in the intercomisural distance (AU)


Subject(s)
Middle Aged , Aged , Male , Female , Humans , Stereotaxic Techniques , Brain Mapping , Parkinson Disease , Subthalamic Nucleus , Electrodes, Implanted , Electric Stimulation Therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...