Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
Add more filters










Publication year range
1.
Struct Dyn ; 9(4): 045101, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35909634

ABSTRACT

Time-resolved x-ray diffraction has been used to measure the low-temperature thermal transport properties of a Pt/Gd3Fe5O12//Gd3Ga5O12 metal/oxide heterostructure relevant to applications in spin caloritronics. A pulsed femtosecond optical signal produces a rapid temperature rise in the Pt layer, followed by heat transport into the Gd3Fe5O12 (GdIG) thin film and the Gd3Ga5O12 (GGG) substrate. The time dependence of x-ray diffraction from the GdIG layer was tracked using an accelerator-based femtosecond x-ray source. The ultrafast diffraction measurements probed the intensity of the GdIG (1 -1 2) x-ray reflection in a grazing-incidence x-ray diffraction geometry. The comparison of the variation of the diffracted x-ray intensity with a model including heat transport and the temperature dependence of the GdIG lattice parameter allows the thermal conductance of the Pt/GdIG and GdIG//GGG interfaces to be determined. Complementary synchrotron x-ray diffraction studies of the low-temperature thermal expansion properties of the GdIG layer provide a precise calibration of the temperature dependence of the GdIG lattice parameter. The interfacial thermal conductance of the Pt/GdIG and GdIG//GGG interfaces determined from the time-resolved diffraction study is of the same order of magnitude as previous reports for metal/oxide and epitaxial dielectric interfaces. The thermal parameters of the Pt/GdIG//GGG heterostructure will aid in the design and implementation of thermal transport devices and nanostructures.

2.
J Synchrotron Radiat ; 29(Pt 3): 876-887, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35511021

ABSTRACT

The diffraction endstation of the NanoMAX beamline is designed to provide high-flux coherent X-ray nano-beams for experiments requiring many degrees of freedom for sample and detector. The endstation is equipped with high-efficiency Kirkpatrick-Baez mirror focusing optics and a two-circle goniometer supporting a positioning and scanning device, designed to carry a compact sample environment. A robot is used as a detector arm. The endstation, in continued development, has been in user operation since summer 2017.

3.
Sci Adv ; 8(13): eabn3535, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35353557

ABSTRACT

The interest in understanding scaling limits of magnetic textures such as domain walls spans the entire field of magnetism from its physical fundamentals to applications in information technologies. Here, we explore antiferromagnetic CuMnAs in which imaging by x-ray photoemission reveals the presence of magnetic textures down to nanoscale, reaching the detection limit of this established microscopy in antiferromagnets. We achieve atomic resolution by using differential phase-contrast imaging within aberration-corrected scanning transmission electron microscopy. We identify abrupt domain walls in the antiferromagnetic film corresponding to the Néel order reversal between two neighboring atomic planes. Our work stimulates research of magnetic textures at the ultimate atomic scale and sheds light on electrical and ultrafast optical antiferromagnetic devices with magnetic field-insensitive neuromorphic functionalities.

4.
Light Sci Appl ; 11(1): 73, 2022 Mar 25.
Article in English | MEDLINE | ID: mdl-35338112

ABSTRACT

New 4th-generation synchrotron sources, with their increased brilliance, promise to greatly improve the performances of coherent X-ray microscopy. This perspective is of major interest for crystal microscopy, which aims at revealing the 3D crystalline structure of matter at the nanoscale, an approach strongly limited by the available coherent flux. Our results, based on Bragg ptychography experiments performed at the first 4th-generation synchrotron source, demonstrate the possibility of retrieving a high-quality image of the crystalline sample, with unprecedented quality. Importantly, the larger available coherent flux produces datasets with enough information to overcome experimental limitations, such as strongly deteriorated scanning conditions. We show this achievement would not be possible with 3rd-generation sources, a limit that has inhibited the development of this otherwise powerful microscopy method, so far. Hence, the advent of next-generation synchrotron sources not only makes Bragg ptychography suitable for high throughput studies but also strongly relaxes the associated experimental constraints, making it compatible with a wider range of experimental set-ups at the new synchrotrons.

5.
Nat Commun ; 13(1): 724, 2022 Feb 07.
Article in English | MEDLINE | ID: mdl-35132068

ABSTRACT

Efficient manipulation of antiferromagnetic (AF) domains and domain walls has opened up new avenues of research towards ultrafast, high-density spintronic devices. AF domain structures are known to be sensitive to magnetoelastic effects, but the microscopic interplay of crystalline defects, strain and magnetic ordering remains largely unknown. Here, we reveal, using photoemission electron microscopy combined with scanning X-ray diffraction imaging and micromagnetic simulations, that the AF domain structure in CuMnAs thin films is dominated by nanoscale structural twin defects. We demonstrate that microtwin defects, which develop across the entire thickness of the film and terminate on the surface as characteristic lines, determine the location and orientation of 180∘ and 90∘ domain walls. The results emphasize the crucial role of nanoscale crystalline defects in determining the AF domains and domain walls, and provide a route to optimizing device performance.

6.
J Synchrotron Radiat ; 28(Pt 6): 1935-1947, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34738949

ABSTRACT

NanoMAX is the first hard X-ray nanoprobe beamline at the MAX IV laboratory. It utilizes the unique properties of the world's first operational multi-bend achromat storage ring to provide an intense and coherent focused beam for experiments with several methods. In this paper we present the beamline optics design in detail, show the performance figures, and give an overview of the surrounding infrastructure and the operational diffraction endstation.

7.
Phys Rev Lett ; 127(15): 157402, 2021 Oct 08.
Article in English | MEDLINE | ID: mdl-34677993

ABSTRACT

Dynamical diffraction effects in thin single crystals produce highly monochromatic parallel x-ray beams with a mutual separation of a few microns and a time delay of a few femtoseconds-the so-called echoes. This ultrafast diffraction effect is used at X-Ray Free Electron Lasers in self-seeding schemes to improve beam monochromaticity. Here, we present a coherent x-ray imaging measurement of echoes from Si crystals and demonstrate that a small surface strain can be used to tune their temporal delay. These results represent a first step toward the ambitious goal of strain tailoring new x-ray optics and, conversely, open up the possibility of using ultrafast dynamical diffraction effects to study strain in materials.

8.
Science ; 372(6542): 630-635, 2021 05 07.
Article in English | MEDLINE | ID: mdl-33858991

ABSTRACT

Unconventional ferroelectricity exhibited by hafnia-based thin films-robust at nanoscale sizes-presents tremendous opportunities in nanoelectronics. However, the exact nature of polarization switching remains controversial. We investigated a La0.67Sr0.33MnO3/Hf0.5Zr0.5O2 capacitor interfaced with various top electrodes while performing in situ electrical biasing using atomic-resolution microscopy with direct oxygen imaging as well as with synchrotron nanobeam diffraction. When the top electrode is oxygen reactive, we observe reversible oxygen vacancy migration with electrodes as the source and sink of oxygen and the dielectric layer acting as a fast conduit at millisecond time scales. With nonreactive top electrodes and at longer time scales (seconds), the dielectric layer also acts as an oxygen source and sink. Our results show that ferroelectricity in hafnia-based thin films is unmistakably intertwined with oxygen voltammetry.

9.
J Synchrotron Radiat ; 28(Pt 2): 538-549, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33650567

ABSTRACT

Compton scattering is generally neglected in diffraction experiments because the incoherent radiation it generates does not give rise to interference effects and therefore is negligible at Bragg peaks. However, as the scattering volume is reduced, the difference between the Rayleigh (coherent) and Compton (incoherent) contributions at Bragg peaks diminishes and the incoherent part may become substantial. The consequences can be significant for coherent diffraction imaging at high scattering angles: the incoherent radiation produces background that smears out the secondary interference fringes, affecting thus the achievable resolution of the technique. Here, a criterion that relates the object shape and the resolution is introduced. The Compton contribution for several object shapes is quantified, and it is shown that the maximum achievable resolution along different directions has a strong dependence on the crystal shape and size.

10.
Sci Adv ; 6(40)2020 Oct.
Article in English | MEDLINE | ID: mdl-33008906

ABSTRACT

Spin electronic devices based on crystalline oxide layers with nanoscale thicknesses involve complex structural and magnetic phenomena, including magnetic domains and the coupling of the magnetism to elastic and plastic crystallographic distortion. The magnetism of buried nanoscale layers has a substantial impact on spincaloritronic devices incorporating garnets and other oxides exhibiting the spin Seebeck effect (SSE). Synchrotron hard x-ray nanobeam diffraction techniques combine structural, elemental, and magnetic sensitivity and allow the magnetic domain configuration and structural distortion to be probed in buried layers simultaneously. Resonant scattering at the Gd L2 edge of Gd3Fe5O12 layers yields magnetic contrast with both linear and circular incident x-ray polarization. Domain patterns facet to form low-energy domain wall orientations but also are coupled to elastic features linked to epitaxial growth. Nanobeam magnetic diffraction images reveal diverse magnetic microstructure within emerging SSE materials and a strong coupling of the magnetism to crystallographic distortion.

11.
Opt Express ; 28(4): 5069-5076, 2020 Feb 17.
Article in English | MEDLINE | ID: mdl-32121735

ABSTRACT

The NanoMAX hard X-ray nanoprobe is the first beamline to take full advantage of the diffraction-limited storage ring at the MAX IV synchrotron and delivers a high coherent photon flux for applications in diffraction and imaging. Here, we characterize its coherent and focused beam using ptychographic analysis. We derive beam profiles in the energy range 6-22 keV and estimate the coherent flux based on a probe mode decomposition approach.

12.
Phys Rev Lett ; 125(24): 246101, 2020 Dec 11.
Article in English | MEDLINE | ID: mdl-33412038

ABSTRACT

Bragg coherent diffraction imaging is a powerful strain imaging tool, often limited by beam-induced sample instability for small particles and high power densities. Here, we devise and validate an adapted diffraction volume assembly algorithm, capable of recovering three-dimensional datasets from particles undergoing uncontrolled and unknown rotations. We apply the method to gold nanoparticles which rotate under the influence of a focused coherent x-ray beam, retrieving their three-dimensional shapes and strain fields. The results show that the sample instability problem can be overcome, enabling the use of fourth generation synchrotron sources for Bragg coherent diffraction imaging to their full potential.

13.
J Synchrotron Radiat ; 27(Pt 1): 134-145, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-31868746

ABSTRACT

Coherent diffractive imaging (CDI) experiments are adequately simulated assuming the thin sample approximation and using a Fresnel or Fraunhofer wavefront propagator to obtain the diffraction pattern. Although this method is used in wave-based or hybrid X-ray simulators, here the applicability and effectiveness of an alternative approach that is based solely on ray tracing of Huygens wavelets are investigated. It is shown that diffraction fringes of a grating-like source are accurately predicted and that diffraction patterns of a ptychography dataset from an experiment with realistic parameters can be sampled well enough to be retrieved by a standard phase-retrieval algorithm. Potentials and limits of this approach are highlighted. It is suggested that it could be applied to study imperfect or non-standard CDI configurations lacking a satisfactory theoretical formulation. The considerable computational effort required by this method is justified by the great flexibility provided for easy simulation of a large-parameter space.

14.
J Synchrotron Radiat ; 26(Pt 5): 1830-1834, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31490177

ABSTRACT

Nanoparticles are essential electrocatalysts in chemical production, water treatment and energy conversion, but engineering efficient and specific catalysts requires understanding complex structure-reactivity relations. Recent experiments have shown that Bragg coherent diffraction imaging might be a powerful tool in this regard. The technique provides three-dimensional lattice strain fields from which surface reactivity maps can be inferred. However, all experiments published so far have investigated particles an order of magnitude larger than those used in practical applications. Studying smaller particles quickly becomes demanding as the diffracted intensity falls. Here, in situ nanodiffraction data from 60 nm Au nanoparticles under electrochemical control collected at the hard X-ray nanoprobe beamline of MAX IV, NanoMAX, are presented. Two-dimensional image reconstructions of these particles are produced, and it is estimated that NanoMAX, which is now open for general users, has the requisites for three-dimensional imaging of particles of a size relevant for catalytic applications. This represents the first demonstration of coherent X-ray diffraction experiments performed at a diffraction-limited storage ring, and illustrates the importance of these new sources for experiments where coherence properties become crucial.

15.
J Synchrotron Radiat ; 26(Pt 4): 1173-1180, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31274441

ABSTRACT

The focusing and coherence properties of the NanoMAX Kirkpatrick-Baez mirror system at the fourth-generation MAX IV synchrotron in Lund have been characterized. The direct measurement of nano-focused X-ray beams is possible by scanning of an X-ray waveguide, serving basically as an ultra-thin slit. In quasi-coherent operation, beam sizes of down to 56 nm (FWHM, horizontal direction) can be achieved. Comparing measured Airy-like fringe patterns with simulations, the degree of coherence |µ| has been quantified as a function of the secondary source aperture (SSA); the coherence is larger than 50% for SSA sizes below 11 µm at hard X-ray energies of 14 keV. For an SSA size of 5 µm, the degree of coherence has been determined to be 87%.

16.
Nano Lett ; 15(2): 981-9, 2015 Feb 11.
Article in English | MEDLINE | ID: mdl-25631459

ABSTRACT

We present the results of the study of the correlation between the electrical and structural properties of individual GaAs nanowires measured in their as-grown geometry. The resistance and the effective charge carrier mobility were extracted for several nanowires, and subsequently, the same nano-objects were investigated using X-ray nanodiffraction. This revealed a number of perfectly stacked zincblende and twinned zincblende units separated by axial interfaces. Our results suggest a correlation between the electrical parameters and the number of intrinsic interfaces.

17.
J Synchrotron Radiat ; 21(Pt 1): 111-8, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24365924

ABSTRACT

Strained semiconductors are ubiquitous in microelectronics and microelectromechanical systems, where high local stress levels can either be detrimental for their integrity or enhance their performance. Consequently, local probes for elastic strain are essential in analyzing such devices. Here, a scanning X-ray sub-microprobe experiment for the direct measurement of deformation over large areas in single-crystal thin films with a spatial resolution close to the focused X-ray beam size is presented. By scanning regions of interest of several tens of micrometers at different rocking angles of the sample in the vicinity of two Bragg reflections, reciprocal space is effectively mapped in three dimensions at each scanning position, obtaining the bending, as well as the in-plane and out-of-plane strain components. Highly strained large-area Ge structures with applications in optoelectronics are used to demonstrate the potential of this technique and the results are compared with finite-element-method models for validation.

18.
Sci Rep ; 3: 1850, 2013.
Article in English | MEDLINE | ID: mdl-23685386

ABSTRACT

Instabilities caused during the erosion of a surface by an ion beam can lead to the formation of self-organized patterns of nanostructures. Understanding the self-organization process requires not only the in-situ characterization of ensemble averaged properties but also probing the dynamics. This can be done with the use of coherent X-rays and analyzing the temporal correlations of the scattered intensity. Here, we show that the dynamics of a semiconductor surface nanopatterned by normal incidence ion beam sputtering are age-dependent and slow down with sputtering time. This work provides a novel insight into the erosion dynamics and opens new perspectives for the understanding of self-organization mechanisms.


Subject(s)
Models, Theoretical , Nanostructures/chemistry , Semiconductors , Materials Testing , Photoelectron Spectroscopy , Surface Properties , X-Rays
19.
J Phys Condens Matter ; 24(44): 445006, 2012 Nov 07.
Article in English | MEDLINE | ID: mdl-23018448

ABSTRACT

Ion beam sputtering is a widely used technique to obtain patterned surfaces. Despite the wide use of this approach on different materials to create surface nanostructures, the theoretical model to explain the time evolution of the erosion process is still debated. We show, with the help of simulations, that two-time correlation functions can serve to assess the validity of different models. These functions can be measured experimentally with the x-ray photon correlation spectroscopy technique.


Subject(s)
Models, Theoretical , Photoelectron Spectroscopy , Surface Properties , Time Factors
20.
Nano Lett ; 11(7): 2875-80, 2011 Jul 13.
Article in English | MEDLINE | ID: mdl-21627099

ABSTRACT

For advanced electronic, optoelectronic, or mechanical nanoscale devices a detailed understanding of their structural properties and in particular the strain state within their active region is of utmost importance. We demonstrate that X-ray nanodiffraction represents an excellent tool to investigate the internal structure of such devices in a nondestructive way by using a focused synchotron X-ray beam with a diameter of 400 nm. We show results on the strain fields in and around a single SiGe island, which serves as stressor for the Si-channel in a fully functioning Si-metal-oxide semiconductor field-effect transistor.


Subject(s)
Germanium/chemistry , Nanotechnology , Quantum Dots , Silicon/chemistry , Transistors, Electronic , Particle Size , Semiconductors , Surface Properties , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...