Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Arzneimittelforschung ; 58(4): 193-8, 2008.
Article in English | MEDLINE | ID: mdl-18540482

ABSTRACT

Blastoferon, in the following referred to as the test product, is a pharmaceutical product of interferon beta la (CAS 220581-49-7) currently marketed as a biosimilar to the innovator Interferon beta la product (referred to as the reference product). Pharmacokinetics and pharmacodynamIcs assays are critically relevant to demonstrate similarity between biopharmaceuticals. The aims of the present study were to investigate the bioavailability (BA) of the test product (either absolute or relative to the innovator product) and to compare the extent of increase of neopterin concentration following administration of either product. Two studies were performed: initially, an absolute BA assay with i.v. and s.c. injection of test product to 12 healthy subjects. Second, a formal relative BA study with s.c. injections of 88 microg of both products to 24 healthy volunteers. Blood samples for pharmacokinetic and pharmacodynamic profiling were drawn at different intervals after injection. Interferon beta (IFNB) concentrations were determined by ELISA. In the absolute BA study, a single s.c. dose of 44 microg of the test product resulted in a median bioavailable fraction of 29%, a median T(max) of 4 h (4-6) and a C(max) of 3.69 (3.27-4.41) IU x ml(-1). In the relative BA study, values for the test product were: median T(max) of 3 h (2-18), C(max) of 5.39 (4.99-6.31) IU x ml(-1), AUC (0-72) of 142.86 (134.16-190.15) IU x h x ml(-1) and AUC(0-infinity) of 190.95 (174.23-303.13) IU x h x ml(-1). The corresponding values for the innovator product were: T(max) of 3 h (1-24), C(max) of 4.44 (4.12-5.40) IU x ml(-1), AUC(0-72) of 128.77 (121.18-170.92) IU x h x ml(-1) and AUC(0-affinity) of 192.61 (183.04-286.46) IU x h x ml(-1). The AUC(0-72) ratio was 111% (CI 90%: 106-116), the AUC(0-affinity) was 99% (CI 90%: 92-107) and the C(max) ratio was 121% (CI 90%: 112-131). IFNB1a increased neopterin levels in both studies. Both products induced side-effects commonly reported for IFN with no serious adverse events. This study presents pharmacokinetics parameters of the test product and demonstrates similar bioavailability of IFNB1a for both pharmaceutical products.


Subject(s)
Immunologic Factors/pharmacokinetics , Interferon Type I/pharmacokinetics , Adult , Area Under Curve , Biological Availability , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunologic Factors/administration & dosage , Immunologic Factors/adverse effects , Injections, Intravenous , Injections, Subcutaneous , Interferon Type I/administration & dosage , Interferon Type I/adverse effects , Male , Neopterin/blood , Recombinant Proteins , Therapeutic Equivalency
2.
J Biotechnol ; 124(2): 469-72, 2006 Jul 13.
Article in English | MEDLINE | ID: mdl-16716426

ABSTRACT

Transgenic farm animals have been proposed as an alternative to current bioreactors for large scale production of biopharmaceuticals. However, the efficiency of both methods in the production of the same protein has not yet been established. Here we report the production of recombinant human growth hormone (hGH) in the milk of a cloned transgenic cow at levels of up to 5 g l(-1). The hormone is identical to that currently produced by expression in E. coli. In addition, the hematological and somatometric parameters of the cloned transgenic cow are within the normal range for the breed and it is fertile and capable of producing normal offspring. These results demonstrate that transgenic cattle can be used as a cost-effective alternative for the production of this hormone.


Subject(s)
Animals, Genetically Modified/genetics , Cattle/genetics , Cloning, Organism , Human Growth Hormone/biosynthesis , Milk Proteins/biosynthesis , Recombinant Proteins/biosynthesis , Animals , Animals, Genetically Modified/embryology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...