ABSTRACT
The authors report monofilament Polyglatin 910 running suture's experience in cataract extraction surgery. The security of this method is procured by:--an adequate wound closure with a complete absorption within eight weeks;--the running suture assured excellent imperviousness;--the physicochemical excellent tolerance of the monofilament.
Subject(s)
Cataract Extraction/instrumentation , Polyglactin 910 , Polymers , Suture Techniques/instrumentation , Absorption , Cornea/surgery , Humans , Sclera/surgery
2.
J Fr Ophtalmol
; 3(12): 743-7, 1980 Dec.
Article
in French
| MEDLINE
| ID: mdl-7217616
ABSTRACT
The authors demonstrate the advantages of a double vestibular and inferior eye lid approach in a case of a blow out fracture of the floor of the orbit associated with a physiologic section syndrome of the sphenoidal hole.
Subject(s)
Fractures, Bone/surgery , Fractures, Closed/surgery , Orbit/injuries , Skull Fractures/surgery , Adult , Eyelids , Female , Fractures, Closed/diagnosis , Humans , Maxillary Sinus , Methods , Ophthalmoplegia/etiology , Orbit/diagnostic imaging , Orbit/surgery , Radiography