Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cancers (Basel) ; 13(12)2021 Jun 09.
Article in English | MEDLINE | ID: mdl-34207878

ABSTRACT

After the first wave of COVID-19, the Spanish Society of Thoracic Surgeons (SECT) surveyed its members to assess the impact of the pandemic on thoracic oncology surgery in Spain. In May 2020, all SECT members were invited to complete an online, 40-item, multiple choice questionnaire. The questionnaire was developed by the SECT Scientific Committee and sent via email. The overall response rate was 19.2%. The respondents answered at least 91.5% of the items, with only one exception (a question about residents). Most respondents (89.3%) worked in public hospitals. The reported impact of the pandemic on routine clinical activity was considered extreme or severe by 75.5% of respondents (25.5% and 50%, respectively). Multidisciplinary tumour boards were held either with fewer members attending or through electronic platforms (44.6% and 35.9%, respectively). Surgical activity decreased by 95.7%, with 41.5% of centers performing surgery only on oncological patients and 11.7% only in emergencies. Nearly 60% of respondents reported modifying standard protocols for early-stage cancer and in the preoperative workup. Most centers (≈80%) reported using full personal protective equipment when operating on COVID-19 positive patients. The COVID-19 pandemic severely affected thoracic oncology surgery in Spain. The lack of common protocols led to a variable care delivery to lung cancer patients.

2.
Invest Radiol ; 41(2): 175-80, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16428989

ABSTRACT

OBJECTIVES: We sought to perform a preliminary comparison of signal-to-noise ratio (SNR) and image quality for magnetic resonance imaging (MRI) of the pancreas at 1.5 and 3 T. MATERIALS AND METHODS: Two imaging cohorts were studied using a T2-weighted, single-shot fast spin-echo pulse sequence and a T1-weighted, fat-suppressed 3D gradient-echo pulse sequence. In the first cohort, 4 subjects were imaged using identical imaging parameters before and after contrast administration at 1.5 and 3.0 T. The SNR was quantified for the pancreas as well as for the liver, spleen, and muscle. In a second cohort of 12 subjects in whom the receiver bandwidth was adjusted for field strength, SNR measurements and qualitative rankings of image quality were performed. RESULTS: In the study cohort using identical imaging parameters at both magnetic field strengths, the mean (SD) ratios of SNR at 3.0 to 1.5 T of the single-shot fast spin-echo images for the pancreas, liver, spleen, and muscle were 1.63 (0.39), 1.82 (0.39), 1.45 (0.18), 2.01 (0.16), respectively. For the precontrast fat-suppressed 3D gradient-echo sequence, the corresponding ratios were 1.28 (0.29), 1.26 (0.30), 1.16 (0.27), and 1.76 (0.45), respectively; for the arterial phase, the corresponding ratios were 2.02 (0.28), 1.60 (0.42), 1.47 (0.26), and 1.94 (0.32), respectively; and for the delayed postcontrast phase, the corresponding ratios were 1.63 (0.51), 2.01 (0.25), 1.66 (0.06), and 2.31 (0.47), respectively. The SNR benefit of 3.0 T was significantly greater on contrast-enhanced as compared with noncontrast T1-weighted 3D gradient-echo images. In the second study cohort, SNR was superior at 3.0 T, although the use of a reduced readout bandwidth at 1.5 T substantially diminished the advantage of the higher field system. With qualitative comparison of images obtained at the 2 magnetic field strengths, the fat-suppressed 3D gradient-echo images obtained at 3.0 T were preferred, whereas the single shot fast spin-echo images obtained at 1.5 T were preferred because of better signal homogeneity. CONCLUSIONS: Our results in a small cohort of volunteers and patients demonstrate a marked improvement in SNR at 3.0 T compared with 1.5 T (by a factor of 2 in some cases) when identical imaging parameters were used. The SNR advantage at 3.0 T is diminished but persists when the receiver bandwidth is adjusted for magnetic field strength. The results suggest that 3.0 T may offer promise for improved body MRI, although further technical development to optimize SNR and improve signal homogeneity will be needed before its full potential can be achieved.


Subject(s)
Image Enhancement , Magnetic Resonance Imaging/methods , Pancreas/anatomy & histology , Adult , Aged , Cohort Studies , Female , Humans , Image Processing, Computer-Assisted , Liver/anatomy & histology , Male , Middle Aged , Pancreatic Diseases/diagnosis , Spleen/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL
...