Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-32668790

ABSTRACT

A minimally invasive implant treatment approach for future full arch implant prosthetic rehabilitations of trophic jaws represents a challenge. An optimal implant planning is strongly related with an accurate merge of the prosthetic information and the radiographic data. To comply with that, most computer aided implantology (CAI) systems require additional steps, as radiographic stents or fiducial markers to overlap digital jaw scans to cone beam computed tomography (CBCT) data. Using dynamic CAI, residual teeth (up to three) make it possible for the merge to avoid new radiographic scans. An additional challenge is the treatment involving immediate implants compared with delayed implants placed into healed bone. As for other static CAI systems, the operator's experience and the quality of the CBCT data make the planning affordable and secure the entire implants placement procedure. The literature reports accuracies in terms of comparison between placed implants and planned implants, following a double CBCT approach, based on radiographic volume overlapping. Thirteen consecutive future totally edentulous patients (77 implants), divided into two groups (group A: 3-4 teeth traced; group B: 5-6 teeth traced) requiring a full arch implant prosthetic rehabilitation were included in the reported case series. A dynamic CAI was used to plan and to place all implants following all the recommended digital steps. The software used provided a tool (Trace and Place) that made the merge between X-ray views of the residual teeth and their own positions possible. This method definitely registered that teeth positions comply with the required accuracy live check. After implants placement, a post-operative CBCT was taken in order to evaluate the deviations of the achieved implants at coronal, apical, and depth level as well as angular deviations. Statistically significant radiological mean difference between the two groups was found in the coronal position of implants (0.26 mm, p < 0.001), in the apical position of implants (0.29 mm, p < 0.001), in the depth of implants (0.16 mm, p = 0.022), and in the angular deviation (0.7, p = 0.004). The use of the TaP technology for the treatment of the patients with at least three stable teeth that need to be removed for a totally implant prosthetic treatment is a promising technique. The performed accuracy analysis demonstrated that this digital protocol can be used without a loss of accuracy of the achieved implants compared to planned ones.


Subject(s)
Mouth, Edentulous , Surgery, Computer-Assisted , Workflow , Computer-Aided Design , Cone-Beam Computed Tomography , Humans , Software
2.
Article in English | MEDLINE | ID: mdl-33542168

ABSTRACT

Computer aided implantology is the safest way to perform dental implants. The research of high accuracy represents a daily effort. The validated method to assess the accuracy of placed dental implants is the superimposition of a pre-operative and a post-operative cone beam computed tomography (CBCT) with planned and placed implants. This procedure is accountable for a biologic cost for the patient. To investigate alternative procedure for accuracy assessment, fifteen resin casts were printed. For each model, six implants were digitally planned and then placed following three different approaches: (a) template guided free hand, (b) static computer aided implantology (SCAI), and (c) dynamic computer aided implantology (DCAI). The placement accuracy of each implant was performed via two methods: the CBCT comparison described above and a matching between implant positions recovered from the original surgical plan with those obtained with a post-operative intraoral scan (IOS). Statistically significant mean differences between guided groups (SCAI and DCAI) and the free hand group were found at all considered deviations, while no differences resulted between the SCAI and DCAI approaches. Moreover, no mean statistically significant differences were found between CBCT and IOS assessment, confirming the validity of this new method.


Subject(s)
Cone-Beam Computed Tomography/methods , Dental Implantation, Endosseous/methods , Dental Implants , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods , Computer-Aided Design , Humans , In Vitro Techniques , Models, Dental , Reproducibility of Results
3.
Ultrason Sonochem ; 15(4): 416-419, 2008 Apr.
Article in English | MEDLINE | ID: mdl-17662635

ABSTRACT

The mineralisation of 2,4-dichlorophenoxyacetic acid (2,4-D) in the presence of zero-valent iron and hydrogen peroxide (the advanced Fenton process--AFP) whilst being subjected to acoustic or hydrodynamic cavitation is reported. If the reaction is merely stirred then there is 57% removal of TOC whilst on irradiation the figure is 64% although the latter reaction is more rapid. Use of ultrasound alone results in only 11% TOC removal in 60 min of treatment time. Addition of iron powder marginally enhances the extent of degradation but an appreciable increase is observed in the presence of hydrogen peroxide which acts as a source for hydroxyl radicals by Fenton chemistry as well as by dissociation in the presence of ultrasound. The use of hydrodynamic cavitation in conjunction with the advanced Fenton process has also been found to be a useful tool for continuous remediation of water contaminated with 2,4-D. After 20 min of treatment the residual TOC is reduced to 30% and this probably represents the remaining highly recalcitrant small organic molecules.


Subject(s)
2,4-Dichlorophenoxyacetic Acid/chemistry , 2,4-Dichlorophenoxyacetic Acid/radiation effects , Hydrogen Peroxide/chemistry , Iron/chemistry , Oxidants/chemistry , Ultrasonics
SELECTION OF CITATIONS
SEARCH DETAIL
...