Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Europace ; 19(8): 1272-1279, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-27940935

ABSTRACT

AIMS: Identification of left atrial (LA) fibrosis through late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) remains controversial due to the heterogeneity and lack of reproducibility of proposed methods. Our aim is to describe a normalized, reproducible, standardized method to evaluate LA fibrosis through LGE-CMR. METHODS AND RESULTS: Electrocardiogram- and respiratory-gated 3-Tesla LGE-CMR was performed in 10 healthy young volunteers and 30 patients with atrial fibrillation (AF): 10 with paroxysmal AF, 10 with persistent AF, and 10 with a previous AF ablation procedure. Local image intensity ratio (IIR) of the LA was calculated as the absolute pixel intensity to mean blood pool intensity ratio. The healthy atrial tissue threshold was defined in young healthy volunteers (upper limit of normality set at IIR tissue mean plus 2 SDs). Dense atrial scarring was characterized in patients with previous radiofrequency-induced scarring (post-AF ablation patients). Validation groups consisted of patients with paroxysmal and persistent AFs. The upper limit of normal IIR was 1.20; IIR values higher than 1.32 (60% of mean maximum pixel intensity in post-ablation patients) were considered dense scar. Image intensity ratio values between 1.2 and 1.32 identified interstitial fibrosis. Patients with paroxysmal and persistent AFs had less atrial fibrotic tissue compared with post-ablation patients. Endocardial bipolar voltage was correlated to IIR values. CONCLUSIONS: An IIR of 1.2 identifies the upper limit of normality in healthy young individuals. An IIR of >1.32 defines dense atrial fibrosis in post-ablation patients. Our results provide a consistent, comparable, and normalized tool to assess atrial arrhythmogenic substrate.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Remodeling , Contrast Media/administration & dosage , Heart Atria/diagnostic imaging , Magnetic Resonance Imaging/standards , Organometallic Compounds/administration & dosage , Action Potentials , Adolescent , Adult , Aged , Atrial Fibrillation/pathology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Cardiac-Gated Imaging Techniques , Case-Control Studies , Catheter Ablation , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Fibrosis , Heart Atria/pathology , Heart Atria/physiopathology , Heart Atria/surgery , Humans , Male , Middle Aged , Predictive Value of Tests , Reference Values , Reproducibility of Results , Young Adult
2.
Heart Rhythm ; 13(1): 37-45, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26272524

ABSTRACT

BACKGROUND: Catheter contact force (CF) has a strong correlation with lesion formation during radiofrequency ablation. Delayed-enhancement cardiac magnetic resonance (DE-CMR) provides lesion information in patients with prior atrial fibrillation (AF) ablation. OBJECTIVE: The aim of this study was to determine the CF threshold to create permanent lesions detected by DE-CMR. METHODS: A total of 36 patients referred for AF ablation were included. A CF catheter was used during the ablation procedure, and DE-CMR was performed 3 months after the ablation procedure. Eighteen pulmonary vein (PV) segments were defined, and 3-dimensional (3D) reconstructions of the left atrium (LA) derived from the DE-CMR images were obtained. One observer evaluated the presence of any discontinuity of previous ablation lesions (gap) in the 3D reconstructions of the LA, and another observer (blinded to the gap findings) determined the minimum CF value in each PV segment. RESULTS: The PV segments where a gap was observed had a lower maximal CF value than did the segments without gap in the 3D LA reconstructions (6.7 ± 4.4 g vs 12.2 ± 4.7 g; P < .001). In receiver operating characteristic analysis, a CF threshold of >8 g provided 73% sensitivity and 81% specificity in the prediction of a complete PV lesion (positive predictive value [PPV] 84%). A CF threshold of >12 g had a specificity of 94% and increased the PPV to 91% in creating a complete lesion in the LA wall (area under the curve 0.834). CONCLUSION: A CF threshold of >12 g H5H20 predicts a complete lesion with high specificity and PPV when a dragging ablation strategy is used in AF ablation.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Cicatrix/diagnosis , Heart Atria , Magnetic Resonance Imaging , Postoperative Complications , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Power Supplies/standards , Female , Heart Atria/pathology , Heart Atria/surgery , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Secondary Prevention/methods , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...