Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1098(1-2): 156-65, 2005 Dec 09.
Article in English | MEDLINE | ID: mdl-16314173

ABSTRACT

The reactivity of phosgene and perfluoroisobutylene (PFIB) towards 1,2-bis-nucleophiles was exploited to allow determination of these gases in air samples. 2-Aminothiophenol (ATP), 3,4-dimercaptotoluene (DMT) and 2-hydroxymethylpiperidine (HMP) were evaluated as bis-nucleophiles capable of forming thermally-stable derivatives with phosgene and PFIB when loaded with triethylamine onto Tenax TA. Experimental design was used to optimise thermal desorption conditions. Detection limits in the low ngm(-3) range were observed for the five derivatives investigated. This work represents the most sensitive analytical method for trace level quantitation of phosgene and PFIB published to date.


Subject(s)
Air/analysis , Chemical Warfare Agents/analysis , Fluorocarbons/analysis , Phosgene/analysis , Aniline Compounds/analysis , Chemical Warfare Agents/chemistry , Ethylamines/chemistry , Gas Chromatography-Mass Spectrometry , Inhalation Exposure , Piperidines/analysis , Sensitivity and Specificity , Sulfhydryl Compounds/analysis , Toluene/analogs & derivatives , Toluene/analysis
2.
J Chromatogr A ; 1068(2): 315-26, 2005 Mar 18.
Article in English | MEDLINE | ID: mdl-15830938

ABSTRACT

Thermal desorption with gas chromatography-mass spectrometry (TD-GC-MS) remains the technique of choice for analysis of trace concentrations of analytes in air samples. This paper describes the development and application of a method for analysing the vesicant compounds sulfur mustard and Lewisites I-III. 3,4-Dimercaptotoluene and butanethiol were used to spike sorbent tubes and vesicant vapours sampled; Lewisite I and II reacted with the thiols while sulfur mustard and Lewisite III did not. Statistical experimental design was used to optimise thermal desorption parameters and the optimum method used to determine vesicant compounds in headspace samples taken from a decontamination trial. 3,4-Dimercaptotoluene reacted with Lewisites I and II to give a common derivative with a limit of detection (LOD) of 260 microg m(-3), while the butanethiol gave distinct derivatives with limits of detection around 30 microg m(-3).


Subject(s)
Arsenicals/analysis , Chemical Warfare Agents/analysis , Gas Chromatography-Mass Spectrometry/methods , Mustard Gas/analysis , Sulfhydryl Compounds/chemistry , Toluene/analogs & derivatives , Arsenicals/chemistry , Chemical Warfare Agents/chemistry , Drug Stability , Hot Temperature , Mustard Gas/chemistry , Sensitivity and Specificity , Toluene/chemistry
3.
Analyst ; 127(9): 1198-202, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12375843

ABSTRACT

A quantitative trace-level thermal desorption gas chromatography mass spectrometry method was developed for chloropicrin CCl3NO2 using central composite design. Factors influencing the thermal decomposition were elucidated and optimum conditions for maximum response deduced. Four factors were investigated: desorption time, desorption temperature, valve temperature and line temperature. Only valve and line temperature influenced the response. The storage stability of chloropicrin on Tenax TA was investigated. Only the storage conditions affected recovery: no significant loss of chloropicrin was observed for spiked tubes stored in a refrigerator for up to 30 days. The application of central composite design to study thermal degradation of chloropicrin has not been described in the literature. The benefits in adopting this approach are reflected in the limit of detection, 22 ng on the sorbent tube (equivalent to 3.2 ppbv), the lowest atmospheric detection limit reported to date.


Subject(s)
Chemical Warfare Agents/analysis , Hydrocarbons, Chlorinated/analysis , Gas Chromatography-Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...