J Assoc Off Anal Chem ; 67(4): 834-7, 1984.
Article in English | MEDLINE | ID: mdl-6206050

ABSTRACT

Although the gas chromatographic separation of the isomers of BHC was demonstrated two decades ago, the present AOAC method of analysis of BHC for gamma-isomer (lindane) content is based on a separation carried out on a liquid chromatographic partition column. A method of analysis has been developed that uses an OV-210 column for separation of the gamma-isomer from the other isomers and impurities in technical BHC. Di-n-propyl phthalate was chosen as an internal standard. The same system allows quantitation of lindane in lotion and shampoo after these products are extracted with ethyl acetate-isooctane (1 + 4). The analytical methods were subjected to a collaborative trial with 10 laboratories. The coefficient of variation for technical BHC was 2.83%. For the water-dispersible powder and emulsifiable concentrate, the coefficients of variation were 2.89% and 4.62%, respectively. Coefficients of variation for 1% lindane lotion and shampoo were 4.36% and 11.92%, respectively. The method has been adopted official first action.


Subject(s)
Hexachlorocyclohexane/analysis , Soaps/analysis , Surface-Active Agents/analysis , Chromatography, Gas/methods , Emulsions , Hair Preparations/analysis , Isomerism , Powders , Suspensions