Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Lab Invest ; 96(9): 1016-25, 2016 09.
Article in English | MEDLINE | ID: mdl-27348626

ABSTRACT

Whereas FDA-approved methods of assessment of estrogen receptor (ER) are 'fit for purpose', they represent a 30-year-old technology. New quantitative methods, both chromogenic and fluorescent, have been developed and studies have shown that these methods increase the accuracy of assessment of ER. Here, we compare three methods of ER detection and assessment on two retrospective tissue microarray (TMA) cohorts of breast cancer patients: estimates of percent nuclei positive by pathologists and by Aperio's nuclear algorithm (standard chromogenic immunostaining), and immunofluorescence as quantified with the automated quantitative analysis (AQUA) method of quantitative immunofluorescence (QIF). Reproducibility was excellent (R(2)>0.95) between users for both automated analysis methods, and the Aperio and QIF scoring results were also highly correlated, despite the different detection systems. The subjective readings show lower levels of reproducibility and a discontinuous, bimodal distribution of scores not seen by either mechanized method. Kaplan-Meier analysis of 10-year disease-free survival was significant for each method (Pathologist, P=0.0019; Aperio, P=0.0053, AQUA, P=0.0026); however, there were discrepancies in patient classification in 19 out of 233 cases analyzed. Out of these, 11 were visually positive by both chromogenic and fluorescent detection. In 10 cases, the Aperio nuclear algorithm labeled the nuclei as negative; in 1 case, the AQUA score was just under the cutoff for positivity (determined by an Index TMA). In contrast, 8 out of 19 discrepant cases had clear nuclear positivity by fluorescence that was unable to be visualized by chromogenic detection, perhaps because of low positivity masked by the hematoxylin counterstain. These results demonstrate that automated systems enable objective, precise quantification of ER. Furthermore, immunofluorescence detection offers the additional advantage of a signal that cannot be masked by a counterstaining agent. These data support the usage of automated methods for measurement of this and other biomarkers that may be used in companion diagnostic tests.


Subject(s)
Breast Neoplasms/metabolism , Fluorescent Antibody Technique/methods , Immunohistochemistry/methods , Receptors, Estrogen/analysis , Automation, Laboratory/methods , Breast Neoplasms/pathology , Chromogenic Compounds/analysis , Chromogenic Compounds/chemistry , Fluorescence , Fluorescent Dyes/analysis , Fluorescent Dyes/chemistry , Humans , Kaplan-Meier Estimate , Prognosis , Receptors, Estrogen/chemistry , Reproducibility of Results , Retrospective Studies , Tissue Array Analysis/methods
2.
Lab Invest ; 94(1): 107-16, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24217091

ABSTRACT

Recent strategies targeting the interaction of the programmed cell death ligand-1 (PD-L1, B7-H1, CD274) with its receptor, PD-1, resulted in promising activity in early phase clinical trials. In this study, we used various antibodies and in situ mRNA hybridization to measure PD-L1 in non-small cell lung cancer (NSCLC) using a quantitative fluorescence (QIF) approach to determine the frequency of expression and prognostic value in two independent populations. A control tissue microarray (TMA) was constructed using PD-L1-transfected cells, normal human placenta and known PD-L1-positive NSCLC cases. Only one of four antibodies against PD-L1 (5H1) validated for specificity on this TMA. In situ PD-L1 mRNA using the RNAscope method was similarly validated. Two cohorts of NSCLC cases in TMAs including 340 cases from hospitals in Greece and 204 cases from Yale University were assessed. Tumors showed PD-L1 protein expression in 36% (Greek) and 25% (Yale) of the cases. PD-L1 expression was significantly associated with tumor-infiltrating lymphocytes in both cohorts. Patients with PD-L1 (both protein and mRNA) expression above the detection threshold showed statistically significant better outcome in both series (log-rank P=0.036 and P=0.027). Multivariate analysis showed that PD-L1 expression was significantly associated with better outcome independent of histology. Measurement of PD-L1 requires specific conditions and some commercial antibodies show lack of specificity. Expression of PD-L1 protein or mRNA is associated with better outcome. Further studies are required to determine the value of this marker in prognosis and prediction of response to treatments targeting this pathway.


Subject(s)
B7-H1 Antigen/biosynthesis , Carcinoma, Non-Small-Cell Lung/metabolism , Lung Neoplasms/metabolism , Aged , B7-H1 Antigen/genetics , B7-H1 Antigen/metabolism , Biomarkers, Tumor/genetics , Biomarkers, Tumor/metabolism , Carcinoma, Non-Small-Cell Lung/genetics , Carcinoma, Non-Small-Cell Lung/immunology , Cell Line, Tumor , Chi-Square Distribution , Cohort Studies , Connecticut , Female , Greece , Humans , Immunohistochemistry , Lung Neoplasms/genetics , Lung Neoplasms/immunology , Lymphocytes, Tumor-Infiltrating/immunology , Male , Prognosis , RNA, Messenger/genetics , RNA, Messenger/metabolism , Reproducibility of Results , Survival Analysis , Tissue Array Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...