Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
ACS Appl Nano Mater ; 7(6): 6242-6252, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38544504

ABSTRACT

This work addresses the need for precise control of thin film sputtering processes to enable thin film material tailoring on the example of zinc tin nitride (ZTN) thin films deposited via microwave plasma-assisted high power reactive magnetron sputtering (MAR-HiPIMS). The applied in situ diagnostic techniques (Langmuir probe and energy-resolved time-of-flight mass spectrometry) supported monitoring changes in the deposition environment with respect to microwave (MW) power. During MAR-HiPIMS, the presence of nitride ions in the gas phase (ZnN+, ZnN2+, SnN+, SnN2+) was detected. This indicates that the MW plasma facilitated their production, as opposed to pure R-HiPIMS. Additionally, MW plasma caused post-ionisation of sputtered atoms and reduced the overall energy-per-charge range of incoming charged species. By varying the MW power and substrate biasing, films with comparable chemical compositions (approximately Zn0.92Sn1.08N2) but different structures, ranging from polycrystalline to preferentially textured, were successfully produced. The application of density functional theory (DFT) further enabled the relationship between the lattice parameters and the optical properties of ZTN to be explored, where the material's optical anisotropy nature was determined. It was found that despite considerable differences in crystallinity, the changes induced in the lattice parameters were subangstrom, causing only minor changes in the final optical properties of ZTN.

2.
EES Catal ; 2(1): 311-323, 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-38222061

ABSTRACT

Electrochemical reduction of CO2 (CO2RR) is an attractive technology to reintegrate the anthropogenic CO2 back into the carbon cycle driven by a suitable catalyst. This study employs highly efficient multi-carbon (C2+) producing Cu2O nanocubes (NCs) decorated with CO-selective Au nanoparticles (NPs) to investigate the correlation between a high CO surface concentration microenvironment and the catalytic performance. Structure, morphology and near-surface composition are studied via operando X-ray absorption spectroscopy and surface-enhanced Raman spectroscopy, operando high-energy X-ray diffraction as well as quasi in situ X-ray photoelectron spectroscopy. These operando studies show the continuous evolution of the local structure and chemical environment of our catalysts during reaction conditions. Along with its alloy formation, a CO-rich microenvironment as well as weakened average CO binding on the catalyst surface during CO2RR is detected. Linking these findings to the catalytic function, a complex compositional interplay between Au and Cu is revealed in which higher Au loadings primarily facilitate CO formation. Nonetheless, the strongest improvement in C2+ formation appears for the lowest Au loadings, suggesting a beneficial role of the Au-Cu atomic interaction for the catalytic function in CO2RR. This study highlights the importance of site engineering and operando investigations to unveil the electrocatalyst's adaptations to the reaction conditions, which is a prerequisite to understand its catalytic behavior.

3.
J Mech Behav Biomed Mater ; 150: 106294, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38128472

ABSTRACT

Tissue fixation is a prevalent method for bone conservation. Bone biopsies are typically fixed in formalin, dehydrated in ethanol, and infiltrated with polymethyl methacrylate (PMMA) Since some experiments can only be performed on fixed bone samples, it is essential to understand how fixation affects the measured material properties. The aim of this study was to quantify the influence of tissue fixation on the mechanical properties of cortical ovine bone at the extracellular matrix (ECM) level with state-of-the-art micromechanical techniques. A small section from the middle of the diaphysis of two ovine tibias (3.5 and 5.5 years old) was cut in the middle and polished on each side, resulting in a pair of mirrored surfaces. For each pair, one specimen underwent a fixation protocol involving immersion in formalin, dehydration with ethanol, and infiltration with PMMA. The other specimen (mirrored) was air-dried. Six osteons were selected in both pairs, which could be identified in both specimens. The influence of fixation on the mechanical properties was first analyzed using micropillar compression tests and nanoindentation in dry condition. Additionally, changes in the degree of mineralization were evaluated with Raman spectroscopy in both fixed and native bone ECM. Finally, micro tensile experiments were conducted in the 3.5-year fixed ovine bone ECM and compared to reported properties of unfixed dry ovine bone ECM. Interestingly, we found that tissue fixation does not alter the mechanical properties of ovine cortical bone ECM compared to experiments in dry state. However, animal age increases the degree of mineralization (p = 0.0159) and compressive yield stress (p = 0.041). Tissue fixation appears therefore as a valid conservation technique for investigating the mechanical properties of dehydrated bone ECM.


Subject(s)
Formaldehyde , Polymethyl Methacrylate , Sheep , Animals , Tissue Fixation/methods , Formaldehyde/chemistry , Ethanol , Extracellular Matrix
4.
JBMR Plus ; 7(12): e10826, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38130764

ABSTRACT

Osteogenesis imperfecta (OI) is a genetic, collagen-related bone disease that increases the incidence of bone fractures. Still, the origin of this brittle mechanical behavior remains unclear. The extracellular matrix (ECM) of OI bone exhibits a higher degree of bone mineralization (DBM), whereas compressive mechanical properties at the ECM level do not appear to be inferior to healthy bone. However, it is unknown if collagen defects alter ECM tensile properties. This study aims to quantify the tensile properties of healthy and OI bone ECM. In three transiliac biopsies (healthy n = 1, OI type I n = 1, OI type III n = 1), 23 microtensile specimens (gauge dimensions 10 × 5 × 2 µm3) were manufactured and loaded quasi-statically under tension in vacuum condition. The resulting loading modulus and ultimate strength were extracted. Interestingly, tensile properties in OI bone ECM were not inferior compared to controls. All specimens revealed a brittle failure behavior. Fracture surfaces were graded according to their mineralized collagen fibers (MCF) orientation into axial, mixed, and transversal fracture surface types (FST). Furthermore, tissue mineral density (TMD) of the biopsy cortices was extracted from micro-computed tomogra[hy (µCT) images. Both FST and TMD are significant factors to predict loading modulus and ultimate strength with an adjusted R 2 of 0.556 (p = 2.65e-05) and 0.46 (p = 2.2e-04), respectively. The influence of MCF orientation and DBM on the mechanical properties of the neighboring ECM was further verified with quantitative polarized Raman spectroscopy (qPRS) and site-matched nanoindentation. MCF orientation and DBM were extracted from the qPRS spectrum, and a second mechanical model was developed to predict the indentation modulus with MCF orientation and DBM (R 2 = 67.4%, p = 7.73e-07). The tensile mechanical properties of the cortical bone ECM of two OI iliac crest biopsies are not lower than the one from a healthy and are primarily dependent on MCF orientation and DBM. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

5.
Acta Biomater ; 164: 332-345, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37059408

ABSTRACT

The hierarchical design of bio-based nanostructured materials such as bone enables them to combine unique structure-mechanical properties. As one of its main components, water plays an important role in bone's material multiscale mechanical interplay. However, its influence has not been quantified at the length-scale of a mineralised collagen fibre. Here, we couple in situ micropillar compression, and simultaneous synchrotron small angle X-ray scattering (SAXS) and X-ray diffraction (XRD) with a statistical constitutive model. Since the synchrotron data contain statistical information on the nanostructure, we establish a direct connection between experiment and model to identify the rehydrated elasto-plastic micro- and nanomechanical fibre behaviour. Rehydration led to a decrease of 65%-75% in fibre yield stress and compressive strength, and 70% in stiffness with a 3x higher effect on stresses than strains. While in agreement with bone extracellular matrix, the decrease is 1.5-3x higher compared to micro-indentation and macro-compression. Hydration influences mineral more than fibril strain with the highest difference to the macroscale when comparing mineral and tissue levels. The effect of hydration seems to be strongly mediated by ultrastructural interfaces while results provide insights towards mechanical consequences of reported water-mediated structuring of bone apatite. The missing reinforcing capacity of surrounding tissue for an excised fibril array is more pronounced in wet than dry conditions, mainly related to fibril swelling. Differences leading to higher compressive strength between mineralised tissues seem not to depend on rehydration while the lack of kink bands supports the role of water as an elastic embedding influencing energy-absorption mechanisms. STATEMENT OF SIGNIFICANCE: Characterising structure-property-function relationships in hierarchical biological materials helps us to elucidate mechanisms that enable their unique properties. Experimental and computational methods can advance our understanding of their complex behaviour with the potential to inform bio-inspired material development. In this study, we close a gap for bone's fundamental mechanical building block at micro- and nanometre length scales. We establish a direct connection between experiments and simulations by coupling in situ synchrotron tests with a statistical model and quantify the behaviour of rehydrated single mineralised collagen fibres. Results suggest a high influence of hydration on structural interfaces, and the role of water as an elastic embedding by outlining important differences between wet and dry elasto-plastic properties of mineral nanocrystals, fibrils and fibres.


Subject(s)
Collagen , Minerals , Scattering, Small Angle , Stress, Mechanical , X-Ray Diffraction
6.
Acta Biomater ; 131: 403-414, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34245895

ABSTRACT

The increased risk of fracture in the elderly associated with metabolic conditions like osteoporosis poses a significant strain on health care systems worldwide. Due to bone's hierarchical nature, it is necessary to study its mechanical properties and failure mechanisms at several length scales. We conducted micropillar compression experiments on ovine cortical bone to assess the anisotropic mechanical response at the lamellar scale over a wide range of strain rates (10-4 to 8·102 s-1). At the microscale, lamellar bone exhibits a strain rate sensitivity similar to what is reported at the macroscale suggesting that it is an intrinsic property of the extracellular matrix. Significant shear band thickening was observed at high strain rates by HRSEM and STEM imaging. This is likely caused by the material's inability to accommodate the imposed deformation by propagation of thin kink bands and shear cracks at high strain rates, leading to shear band thickening and nucleation. The post-yield behavior is strain rate and direction dependent: hardening was observed for transverse oriented micropillars and hardening modulus increases with strain rate by a factor of almost 2, while axially oriented micropillars showed strain softening and an increase of the softening peak width and work to ultimate stress as a function of strain rate. This suggests that for compression at the micrometer scale, energy absorption in bone increases with strain rate. This study highlights the importance of investigating bone strength and post-yield behavior at lower length scales, under hydrated conditions and at clinically relevant strain rates. STATEMENT OF SIGNIFICANCE: We performed micropillar compression experiments of ovine cortical bone at two different orientations and over seven orders of magnitude of strain rate. Experiments were performed under humid condition to mimic the natural conditions of bone in a human body using a newly developed micro-indenter setup. The strain rate sensitivity was found to be of a similar magnitude to what has been reported for higher length scales, suggesting that the strain rate sensitivity is an intrinsic property of the bone extracellular matrix. In addition, localized shear deformation in thick bands was observed for the first time at high strain rates, highlighting the importance of investigating bone under conditions representative of an accident or fall at several length scales.


Subject(s)
Bone and Bones , Cortical Bone , Aged , Animals , Compressive Strength , Extracellular Matrix , Humans , Pressure , Sheep , Stress, Mechanical
7.
Acta Biomater ; 131: 391-402, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34175475

ABSTRACT

A mechanistic understanding of bone fracture is indispensable for developing improved fracture risk assessment in clinics. Since bone is a hierarchically structured material, gaining such knowledge requires analysis at multiple length scales. Here, the tensile response of cortical bone is characterized at the lamellar length scale under dry and hydrated conditions with the aim of investigating the influence of bone's microstructure and hydration on its microscale strength and toughness. For individual lamellae, bone strength strongly correlates with the underlying mineralized collagen fibrils orientation and shows a 2.3-fold increase compared to the macroscale. When specimen size is increased to a few lamellae, the influence of fibril orientation and the size effect on strength are significantly reduced. These findings highlight the critical influence of defects, such as canaliculi and interlamellar interfaces, when assessing larger volumes. Hydration leads up to a 3-fold strength decrease but activates several toughening mechanisms enabling inelastic deformation. In axial specimens, toughening is seen through fibril bridging and crack kinking. In transverse specimens, water presence leads to a progressive but stable crack growth parallel to the fibril orientation, suggesting crack-tip plasticity at the fibrillar interfaces. This work offers a better understanding of the role of interfaces, porosity, and hydration in crack initiation under tensile loading, which is a crucial step towards improved clinical management of disease-related bone fractures through multiscale modeling approaches. STATEMENT OF SIGNIFICANCE: Bone features a complex hierarchical structure which gives rise to several toughening mechanisms across several length scales. To better understand bone fracture, particularly the changes associated with age and disease, it is essential to investigate bone mechanical response at different levels of its hierarchical structure. For the first time, we were able to observe the nucleation of a single crack in hydrated bone lamellae under well-controlled uniaxial tensile loading conditions. These experiments highlight the role of water, interfaces, defects, and the ratio of defect to specimen size on bone's apparent strength and toughness. Such knowledge can be used in the future to develop multiscale models enabling improved clinical management of disease-related bone fractures.


Subject(s)
Bone and Bones , Fractures, Bone , Cortical Bone , Cytoskeleton , Extracellular Matrix , Humans
8.
J Bone Miner Res ; 36(7): 1364-1375, 2021 07.
Article in English | MEDLINE | ID: mdl-33740286

ABSTRACT

Osteogenesis imperfecta (OI) is an inheritable, genetic, and collagen-related disorder leading to an increase in bone fragility, but the origin of its "brittle behavior" is unclear. Because of its complex hierarchical structure, bone behaves differently at various length scales. This study aims to compare mechanical properties of human OI bone with healthy control bone at the extracellular matrix (ECM) level and to quantify the influence of the degree of mineralization. Degree of mineralization and mechanical properties were analyzed under dry conditions in 12 fixed and embedded transiliac crest biopsies (control n = 6, OI type I n = 3, OI type IV n = 2, and OI type III n = 1). Mean degree of mineralization was measured by microcomputed tomography at the biopsy level and the mineral-to-matrix ratio was assessed by Raman spectroscopy at the ECM level. Both methods revealed that the degree of mineralization is higher for OI bone compared with healthy control. Micropillar compression is a novel technique for quantifying post-yield properties of bone at the ECM level. Micropillars (d = 5 µm, h = 10 µm) were fabricated using focused ion beam milling and quasi-statically compressed to capture key post-yield properties such as ultimate strength. The qualitative inspection of the stress-strain curves showed that both OI and healthy control bone have a ductile response at the ECM level. The quantitative results showed that compressive strength is not reduced in OI bone and is increasing with OI severity. Nanoindentation measurements revealed that OI bone tends to have a higher Young's modulus, hardness, and dissipated energy compared with healthy bone. Micropillar strength and indentation modulus increased linearly and significantly (p < .0001) with mineral-to-matrix ratio. In conclusion, this study indicates that compressive mechanical properties of dry OI bone at the iliac crest are not inferior to healthy control at the ECM level and increase with mineralization. © 2021 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


Subject(s)
Osteogenesis Imperfecta , Bone Density , Compressive Strength , Extracellular Matrix , Humans , Ilium/diagnostic imaging , Osteogenesis Imperfecta/diagnostic imaging , X-Ray Microtomography
9.
Acta Biomater ; 120: 135-145, 2021 01 15.
Article in English | MEDLINE | ID: mdl-32428682

ABSTRACT

Bone features a remarkable combination of toughness and strength which originates from its complex hierarchical structure and motivates its investigation on multiple length scales. Here, in situ microtensile experiments were performed on dry ovine osteonal bone for the first time at the length scale of a single lamella. The micromechanical response was brittle and revealed larger ultimate tensile strength compared to the macroscale (factor of 2.3). Ultimate tensile strength for axial and transverse specimens was 0.35 ± 0.05 GPa and 0.13 ± 0.02 GPa, respectively. A significantly greater strength anisotropy relative to compression was observed (axial to transverse strength ratio of 2.7:1 for tension, 1.3:1 for compression). Fracture surface and transmission electron microscopic analysis suggested that this may be rationalized by a change in failure mode from fibril-matrix interfacial shearing for axial specimens to fibril-matrix debonding in the transverse direction. An improved version of the classic Hashin's composite failure model was applied to describe lamellar bone strength as a function of fibril orientation. Together with our experimental observations, the model suggests that cortical bone strength at the lamellar level is remarkably tolerant to variations of fibrils orientation of about ±30°. This study highlights the importance of investigating bone's hierarchical organization at several length scales for gaining a deeper understanding of its macroscopic fracture behavior. STATEMENT OF SIGNIFICANCE: Understanding bone deformation and failure behavior at different length scales of its hierarchical structure is fundamental for the improvement of bone fracture prevention, as well as for the development of multifunctional bio-inspired materials combining toughness and strength. The experiments reported in this study shed light on the microtensile properties of dry primary osteonal bone and establish a baseline from which to start further investigations in more physiological conditions. Microtensile specimens were stronger than their macroscopic counterparts by a factor of 2.3. Lamellar bone strength seems remarkably tolerant to variations of the sub-lamellar fibril orientation with respect to the loading direction (±30°). This study underlines the importance of studying bone on all length scales for improving our understanding of bone's macroscopic mechanical response.


Subject(s)
Bone and Bones , Fractures, Bone , Animals , Cortical Bone , Pressure , Sheep , Stress, Mechanical , Tensile Strength
10.
Ultramicroscopy ; 184(Pt A): 267-273, 2018 01.
Article in English | MEDLINE | ID: mdl-29024877

ABSTRACT

The current work represents the first implementation of Zernike phase contrast for compound refractive lens based x-ray microscopy, and also the first successful Zernike phase contrast experiment at photon energies above 12 keV. Phase contrast was achieved by fitting a compound refractive lens with a circular phase plate. The resolution is demonstrated to be sub-micron, and can be improved using already existing technology. The possibility of combining the technique with polychromatic radiation is considered, and a preliminary test experiment was performed with positive results.

11.
Acta Biomater ; 60: 302-314, 2017 09 15.
Article in English | MEDLINE | ID: mdl-28754646

ABSTRACT

Bone features a hierarchical architecture combining antagonistic properties like toughness and strength. In order to better understand the mechanisms leading to this advantageous combination, its postyield and failure behaviour was analyzed on the length scale of a single lamella. Micropillars were compressed to large strains under hydrated conditions to measure their anisotropic yield and post-yield behaviour. An increase in strength compared to the macroscale by a factor of 1.55 and a strong influence of hydration with a decrease by 60% in yield stress compared to vacuum conditions were observed. Post-compression transmission electron microscopic analysis revealed anisotropic deformation mechanisms. In axial pillars, where fibrils were oriented along the loading axis, kink bands were observed and shear cracks emerged at the interface of ordered and disordered regions. Micromechanical analysis of fibril kinking allowed an estimate of the extrafibrillar matrix shear strength to be made: 120±40MPa. When two opposing shear planes met a wedge was formed, splitting the micropillar axially in a mode 1 crack. Making use of an analytical solution, the mode 1 fracture toughness of bone extracellular matrix for splitting along the fibril direction was estimated to be 0.07MPam. This is 1-2 orders of magnitude smaller than on the macroscale, which may be explained by the absence of extrinsic toughening mechanisms. In transverse pillars, where fibrils were oriented perpendicular to the loading axis, cracks formed in regions where adverse fibril orientation reduced the local fracture resistance. This study underlines the importance of bone's hierarchical microstructure for its macroscopic strength and fracture resistance and the need to study structure-property relationships as well as failure mechanisms under hydrated conditions on all length scales. STATEMENT OF SIGNIFICANCE: Bone's hierarchical architecture combines toughness and strength. To understand the governing deformation mechanisms, its postyield behaviour was analyzed at the microscale. Micropillars were compressed in physiological solution; an increased strength compared to macroscale and an influence of hydration was found. Transmission electron microscopy revealed cracks forming in regions with adverse fibril orientation in transverse pillars. In axial pillars kink bands were observed and shear cracks emerged at the interface of ordered and disordered regions. It was estimated that bone's fracture toughness for splitting between fibrils is significantly smaller than on the macroscale. This study underlines the importance of bone's hierarchical microstructure and the need to study structure-property relationships on all length scales.


Subject(s)
Bone and Bones/chemistry , Extracellular Matrix/chemistry , Shear Strength , Stress, Mechanical , Animals , Sheep
12.
ACS Nano ; 9(12): 12383-91, 2015 Dec 22.
Article in English | MEDLINE | ID: mdl-26498131

ABSTRACT

We fabricate and characterize large-area plasmonic substrates that feature asymmetric periodic nanostructures made of aluminum. Strong coupling between localized and propagating plasmon resonances leads to characteristic Fano line shapes with tunable spectral positions and widths. Distinctive colors spanning the entire visible spectrum are generated by tuning the system parameters, such as the period and the length of the aluminum structures. Moreover, the asymmetry of the aluminum structures gives rise to a strong symmetry broken color rendering effect, for which colors are observed only from one side of the surface normal. Using a combination of immersed laser interference lithography and nanoimprint lithography, our color rendering structures can be fabricated on areas many inches in size. We foresee applications in anticounterfeiting, photovoltaics, sensing, displays, and optical security.

SELECTION OF CITATIONS
SEARCH DETAIL
...