Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2754-2761, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37042977

ABSTRACT

PURPOSE: External snapping hip is caused by the iliotibial band snapping from the greater trochanter during hip movement. The aim of this study was to compare a technique of ultrasound-guided iliotibial band release versus a similar endoscopic technique. METHODS: An anatomical study was performed on 10 cadavers i.e. 20 hips. The same operator performed ultrasound-guided and endoscopic iliotibial band release on either side of each specimen. An independent operator performed an open control to verify the outcome measures. The primary outcome was iliotibial cutting percentage, defined as the ratio of the transversal cut distance and the width of the iliotibial at the most prominent portion of the great trochanter. Secondary outcomes included nerve injuries. The surgical time was assessed and disposable medical supplies costs were estimated. RESULTS: The average cutting percentage was 95% ± 8 by ultrasound, compared with 91% ± 11 by endoscopy (n.s.). No iatrogenic lesions were found, particularly nerve damage. The average duration of the ultrasound procedure was 12.3 minutes ± 6 compared to 21 minutes ± 10.7 for endoscopy (p=0.04), with a 3-fold decrease between the first and last procedure, regardless of the technique. The ultrasound procedure was 3 times less expensive in terms of disposable medical supplies (120.5€ versus 353.5€). CONCLUSION: This technique of ultrasound-guided iliotibial band release appears to be as effective and safe as a similar endoscopic technique. The surgical time is reasonable for a surgeon trained in ultrasound, with lower disposable supplies costs. A comparative clinical study is further needed to assess the actual benefits of each technique.


Subject(s)
Hip Joint , Joint Diseases , Humans , Operative Time , Hip Joint/surgery , Endoscopy , Joint Diseases/surgery , Ultrasonography, Interventional
2.
Orthop Traumatol Surg Res ; 109(1): 103477, 2023 02.
Article in English | MEDLINE | ID: mdl-36375721

ABSTRACT

INTRODUCTION: Despite the optimization of implant positioning, the clinical benefit of the use of robotic assistance during THA remains uncertain. In this case-control study (robotic versus manual technique) we made a retrospective short-term comparison of: (1) the functional results, (2) the complications, (3) and the influence of radiological symmetrization of the hips on the functional result. HYPOTHESIS: The use of a robotic arm improved the functional results of a THA. MATERIALS AND METHOD: A retrospective case-control study was performed, including patients with unilateral hip osteoarthritis who underwent a robotic arm-assisted THA (THA-R). The controls (THA-C) were matched according to age, sex, body mass index and surgical approach. The Harris (HHS), Oxford (OHS) and Forgotten Joint (FJS) scores were collected preoperatively and 1 year postoperatively. At each review, complications were categorized into minor events, revision surgery with and without implant change. Radiographic analysis was performed on weight-bearing images of the pelvis 3 months postoperatively. The objective of the surgery was symmetrization of the THA in the contralateral healthy hip. For each measured parameter of the hip joint center of rotation (COR), global offset (GO) and articular leg length discrepancy (aLLD), the difference between the two sides corresponding to the delta symmetrization was compared. RESULTS: Ninety-eight patients were included in the THA-R group and matched to 98 controls in the THA-C group. At 1 year postoperatively, the FJS and OHS scores were statistically higher in the THA-R group, respectively 82.1±22.3 [8.3; 100] and 40.8±8.8 [6; 48] vs. 71.2±27.8 [0; 100] and 38.1±9.7 [12; 48] in the THA-C group (p=0.004 and p=0.043). There was no difference in HHS (THA-R: 85.9±15.8 [31; 100] vs. THA-C: 85.8±13.3 [49-100] (p=0.962)). The implant revision rate at 1 year was significantly higher in the THA-C group (0% vs. 5.1% (p=0.025)). There was no difference in the reoperation without component exchange despite 3 dislocations (3.1%) in the THA-R group (5 (5.1%) vs. 9 (9.2%) (p=0.273)). The rate of abarticular pathologies (ilio-psoas irritation and greater trochanteric bursitis) was higher in the THA-C group (10 (10.8%) vs. 2 (2%) (p=0.016). Robotic acetabular assistance allowed a significantly better restitution of the horizontal position (THA-R: 1mm±4.8 [-11.7; 12.6] vs. THA-C: 4.1mm±7 [-29.6; 28] (p=0.0005)) and vertical COR (THA-R: 0.5mm±3.1 [-6; 8.3] vs. THA-C: 2mm±4.1 [-6; 14.6] (p=0.0068)). Navigated assistance of the femur did not significantly optimize the restitution of the Global Offset (THA-R: +2mm±6.4 [-16.4; 27.6] vs. THA-C: +0.5mm±7 .7 [-34; 30.2] (p=0.145)), or lower limb length (THA-R: +1.1mm±5 [-8.2; 13.5] vs. THA-C: +0.3mm±6 [-14.1; 22.5] (p=0.344). The FJS was statistically correlated with the restoration of the symmetry of the COR and the aLLD. A post-hoc power analysis confirmed sufficient potency (1-ß=0.85). CONCLUSION: Robotic acetabular assistance combined with femoral navigation improves clinical outcomes of THAs with fewer short-term complications. The precision of the positioning of the implants, optimized by the computer-assisted surgery system, is correlated with the missed joint score. LEVEL OF EVIDENCE: III, retrospective case-control study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Hip/methods , Robotic Surgical Procedures/methods , Retrospective Studies , Case-Control Studies , Propensity Score , Acetabulum/diagnostic imaging , Acetabulum/surgery , Femur/surgery , Leg Length Inequality/surgery , Treatment Outcome
3.
J Ultrasound Med ; 40(10): 2213-2217, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33340134

ABSTRACT

The surgical treatment of external coxa saltans is not standardized. Many techniques for iliotibial release have been described, both open and arthroscopic. No technique describes ultrasound release. In this cadaveric study, we describe a minimally invasive technique for percutaneous iliotibial release with ultrasound guidance, designed to be performed under local anesthesia. The future objective would be to perform an active intraoperative test of the snapping hip to confirm adequate release, thus reducing the risk of recurrence.


Subject(s)
Hip , Joint Diseases , Cadaver , Hip Joint , Humans , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL
...