Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Bone Joint J ; 101-B(1): 15-21, 2019 01.
Article in English | MEDLINE | ID: mdl-30601057

ABSTRACT

AIMS: The glenohumeral joint is the most frequently dislocated articulation, but possibly due to the lower prevalence of posterior shoulder dislocations, approximately 50% to 79% of posterior glenohumeral dislocations are missed at initial presentation. The aim of this study was to systematically evaluate the most recent evidence involving the aetiology of posterior glenohumeral dislocations, as well as the diagnosis and treatment. MATERIALS AND METHODS: A systematic search was conducted using PubMed (MEDLINE), Web of Science, Embase, and Cochrane (January 1997 to September 2017), with references from articles also evaluated. Studies reporting patients who experienced an acute posterior glenohumeral joint subluxation and/or dislocation, as well as the aetiology of posterior glenohumeral dislocations, were included. RESULTS: A total of 54 studies met the inclusion criteria. In total, 182 patients were included in this analysis; study sizes ranged from one to 66 patients, with a mean age of 44.2 years (sd 13.7). There was a higher proportion of male patients. In all, 216 shoulders were included with 148 unilateral injuries and 34 bilateral. Seizures were implicated in 38% of patients (n = 69), with falls, road traffic accidents, electric shock, and iatrogenic reasons also described. Time to diagnosis varied across studies from immediate up to a delay of 25 years. Multiple associated injuries are described. CONCLUSION: This review provides an up-to-date insight into the aetiology of posterior shoulder dislocations. Our results showed that seizures were most commonly implicated. Overall, reduction was achieved via open means in the majority of shoulders. We also found that delayed diagnosis is common.


Subject(s)
Shoulder Dislocation/etiology , Accidental Falls , Accidents, Traffic , Adult , Electric Injuries/complications , Epidemiologic Methods , Female , Humans , Male , Seizures/complications
2.
J Child Orthop ; 11(3): 210-215, 2017 Jun 01.
Article in English | MEDLINE | ID: mdl-28828065

ABSTRACT

PURPOSE: Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. METHODS: Retrospective review of all the femoral lengthening performed by the senior author was performed. The medical and physiotherapy notes were reviewed. The gender, age at time of surgery, disease aetiology, total days in the external fixator and length of the new regenerate bone were recorded. Patients who sustained a regenerate fracture were identified. RESULTS: A total of 176 femoral lengthening procedures were performed on 108 patients. Eight regenerate fractures occurred in seven patients (4.5%). The mechanism of injury was a fall in five cases and during physiotherapy in three cases. The regenerate fracture occurred a median number of nine days following removal of frame. There was no significant difference between gender, age at time of surgery, total time in external fixator between those who sustained a regenerate fracture and those patients who did not. A significant difference was noted between the amount of lengthening between the 'regenerate fracture group' and the 'no fracture group' (50 mm vs 38 mm, respectively; p = 0.029). There was no association between disease aetiology and risk of regenerate fracture. CONCLUSIONS: Femoral lengthening of more than 50 mm increases the risk of a fracture at the regenerate site regardless of the disease aetiology. We recommend avoidance of aggressive physiotherapy for the initial four weeks following external fixator removal.

3.
Osteoarthritis Cartilage ; 23(6): 1018-25, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25724257

ABSTRACT

OBJECTIVE: The objective of this study was to assess the biomechanical stability of three types of chondral flap repair techniques as well as a hydrogel scaffold implantation on the acetabular articular surface using a physiological human cadaveric model. METHODS: Chondral flaps were created in the antero-superior zone of the acetabulum in a series of human cadaveric hip joints. The chondral flap was repaired by fibrin glue, cyanoacrylate, suture technique and an agarose hydrogel scaffold sealed with fibrin glue using six hips in each case. After each repair, the specimens were mounted in a validated jig and tested for 1500 gait cycles. In order to determine the stability of the repair, specimens were evaluated arthroscopically at specific intervals. RESULTS: The fibrin glue and cyanoacrylate techniques were technically the easiest to perform arthroscopically, all flaps repaired with fibrin were detached at 50 cycles while those repaired with cyanoacrylate lasted for an average of 635 cycles. On the other hand, both the suture repair and scaffold implantation techniques were more technically challenging but were both stable till the endpoint of 1500 cycles. CONCLUSION: Fibrin glue on its own does not provide sufficient fixation to repair chondral flaps on the acetabular surface. Cyanoacrylate repairs universally failed midway through the testing protocol employed here, raising doubts as to the effectiveness of that technique. The suture and hydrogel scaffold technique were the most reliable for chondral repair at any given cycle. The results of this biomechanical study demonstrate the relative effectiveness of chondral repair and fixation techniques.


Subject(s)
Cartilage, Articular/surgery , Hip Injuries/surgery , Acetabulum/surgery , Arthroscopy , Cadaver , Cartilage, Articular/injuries , Cyanoacrylates/therapeutic use , Fibrin Tissue Adhesive/therapeutic use , Gait/physiology , Humans , Kaplan-Meier Estimate , Stress, Mechanical , Surgical Flaps , Suture Techniques , Tissue Scaffolds , Weight-Bearing/physiology , Wound Healing
4.
Injury ; 44(2): 178-82, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23000053

ABSTRACT

The aim of this pilot study was to assess a new method of training for peri-acetabular screw placement under indirect vision using standard C-arm fluoroscopy using a porcine model. Two novice orthopaedic residents placed 72 screws (36 each) about the acetabula of six porcine pelves under C-arm fluoroscopic guidance. Unsatisfactory screw position was noted in 22 of 72, with five instances of screw ingress into the hip joint. All of these cases occurred in the first half of each resident's series. Screw direction and final position improved over subsequent trials. This pilot study demonstrates that surgical simulation techniques are applicable in percutaneous screw fixation. Such an approach could be useful for both residents in training and more experienced surgeons who wish to perform this procedure in cases where it is appropriate.


Subject(s)
Acetabulum/surgery , Bone Screws , Fluoroscopy/methods , Fracture Fixation, Internal/methods , Surgery, Computer-Assisted/methods , Acetabulum/anatomy & histology , Animals , Feasibility Studies , Internship and Residency , Pilot Projects , Reproducibility of Results , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...