1.
Heart ; 89(1): 84-90, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12482801

ABSTRACT

OBJECTIVE: To compare the effects of arterial remodelling and plaque characteristics on the mechanisms of direct stenting and predilatation stenting. Direct stenting has become routine in some laboratories and differs technically from predilatation stenting. METHODS: Pre- and post-interventional volumetric intravascular ultrasound (IVUS) was undertaken in 30 patients with direct stenting and in 30 with predilatation stenting of non-calcified native coronary lesions, using the same stent design and stent length. Lumen, vessel (external elastic membrane (EEM)), and plaque (plaque + media) volumes were calculated. Remodelling was determined by comparing the EEM area at the centre of the lesion with the EEM areas at proximal and distal reference sites. Plaque eccentricity was defined as the thinnest plaque diameter to the thickest plaque diameter ratio. Plaque composition was characterised as soft, mixed, or dense. RESULTS: All volumetric IVUS changes were similar in the two groups. Pre-intervention remodelling remained uninfluenced after direct stenting, but was neutralised after predilatation stenting. Eccentric lesions responded to intervention by a greater luminal gain owing to greater vessel expansion in direct stenting. Plaque composition influenced luminal gain in direct stenting, the gain being greatest in the softest plaques; in predilatation stenting, luminal gain was equivalent but vessel expansion was greater for "dense" plaque and plaque reduction greater for "soft" plaque. CONCLUSIONS: In non-calcified lesions, the mechanisms of lumen enlargement after direct or predilatation stenting are significantly influenced by atherosclerotic remodelling, plaque eccentricity, and plaque composition.


Subject(s)
Coronary Artery Disease/pathology , Coronary Vessels/pathology , Stents , Catheterization/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Elasticity , Humans , Observer Variation , Phantoms, Imaging , Predictive Value of Tests , Pressure , Reference Values , Sensitivity and Specificity , Ultrasonography
2.
Circulation ; 104(25): 3020-2, 2001 Dec 18.
Article in English | MEDLINE | ID: mdl-11748092

ABSTRACT

BACKGROUND: We used serial volumetric (post-irradiation and follow-up) intravascular ultrasound (IVUS) to compare the effectiveness of gamma-irradiation ((192)Ir) in saphenous vein graft (SVG) versus native coronary artery in-stent restenosis (ISR). METHODS AND RESULTS: The study population consisted of 47 patients with native coronary artery ISR from WRIST (Washington Radiation for In-Stent Restenosis Trial) and 31 patients with SVG ISR (12 from the WRIST and 19 from SVGWRIST). After irradiation and at 6-month follow-up, stent, lumen, and intimal hyperplasia (IH, stent minus lumen) areas were measured every 1 mm. ISR length was similar in the 2 groups (29+/-12 versus 29+/-14 mm, P=0.9). Post-intervention measurements of stent (280+/-154 versus 324+/-270 mm(3), P=0.4), lumen (184+/-91 versus 214+/-172 mm(3), P=0.3), and IH (96+/-77 versus 109+/-119 mm(3), P=0.5) volumes were similar in the 2 groups. The post-intervention minimum lumen cross sectional areas tended to be smaller in native artery ISR lesions (4.7+/-1.7 versus 5.4+/-1.6 mm(2), P=0.11). During follow-up, there was a slight increase in IH volume (9+/-38 mm(3)) in native artery ISR lesions and a slight decrease in IH volume in SVG ISR lesions (-9+/-32 mm(3), P=0.0463). There was also a slight decrease in minimum lumen area in the native artery ISR lesions versus a slight increase in minimum lumen area in the SVG ISR lesions (-0.8+/-1.7 versus 0.2+/-1.1, P=0.0087). As a result, the follow-up minimum lumen area in native artery lesions was smaller than in SVG ISR lesions (4.1+/-2.1 mm(2) versus 5.6+/-2.2 mm(2), P=0.0067). CONCLUSION: gamma-Irradiation with (192)Ir brachytherapy appears to be as effective in SVGs as it is in native artery ISR lesions.


Subject(s)
Coronary Disease/radiotherapy , Coronary Vessels/radiation effects , Gamma Rays/therapeutic use , Saphenous Vein/transplantation , Stents , Aged , Coronary Angiography , Coronary Disease/diagnostic imaging , Coronary Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Radiotherapy Dosage , Treatment Outcome , Ultrasonography, Interventional
4.
Am Heart J ; 142(6): 970-4, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11717599

ABSTRACT

OBJECTIVES: Serial intravascular ultrasonographic (IVUS) studies have shown that in-stent restenosis is the result of intimal hyperplasia (IH). However, routine preintervention IVUS imaging has suggested that many restenotic stents were inadequately deployed. The purpose of this IVUS study was to determine the incidence of mechanical problems contributing to in-stent restenosis (ISR). METHODS: Between April 1994 and June 2000, 1090 patients with ISR were treated at the Washington Hospital Center. All underwent preintervention IVUS imaging. IVUS measurements included proximal and distal reference lumen areas and diameters; stent, minimum lumen, and IH (stent minus lumen) areas; and IH burden (IH/stent area). RESULTS: In 49 ISR lesions (4.5%), there were morphologic findings that contributed to the restenosis. These were termed mechanical complications. Examples include (1) missing the lesion (eg, an aorto-ostial stenosis), (2) stent "crush," and (3) having the stent stripped off the balloon during the implantation procedure. Excluding mechanical complications, stent underexpansion was common. In 20% of the ISR cases the stents had a cross-sectional area (CSA) at the site of the lesion <80% of the average reference lumen area. Twenty percent of lesions had a minimum stent area <5.0 mm(2) and an additional 18% had a minimum stent area of 5.0 to 6.0 mm(2). Twenty-four percent of lesions had an IH burden <60%. CONCLUSION: Mechanical problems related to stent deployment procedures contribute to a significant minority of ISR lesions (approximately 25%).


Subject(s)
Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Stents/adverse effects , Equipment Failure Analysis , Female , Humans , Hyperplasia/diagnostic imaging , Male , Recurrence , Retrospective Studies , Tunica Intima/diagnostic imaging , Ultrasonography, Interventional
5.
Am J Cardiol ; 88(4): 365-70, 2001 Aug 15.
Article in English | MEDLINE | ID: mdl-11545755

ABSTRACT

The purpose of this study was to use intravascular ultrasound (IVUS) to clarify the morphology of coronary aneurysms diagnosed by angiography. Seventy-seven consecutive patients with an aneurysmal dilatation in a native coronary artery diagnosed by angiography (defined as a lesion lumen diameter 25% larger than reference) were evaluated by IVUS. IVUS true aneurysms were defined as having an intact vessel wall and a maximum lumen area 50% larger than proximal reference. IVUS pseudoaneurysms had a loss of vessel wall integrity and damage to adventitia or perivascular tissue. Complex plaques were lesions with ruptured plaque or spontaneous or unhealed dissection. Aneurysmal dilatation and reference segments were assessed using standard IVUS quantitative techniques. Twenty-one lesions (27%) were classified as true aneurysms, 3 (4%) were classified as pseudoaneurysms, 12 (16%) were complex plaques, and the other 41 (53%) were normal arterial segments adjacent to > or =1 stenosis. The maximum lumen area within the aneurysmal segment was largest for pseudoaneurysm (35.1 +/- 10.4 mm(2)), 22.1 +/- 9.9 mm(2) for true aneurysm, and similar for complex plaques (11.2 +/- 3.5 mm(2)) and normal segments with adjacent stenoses (13.8 +/- 6.4 mm(2)): analysis of variance, p <0.0001. Only one third of angiographically diagnosed aneurysms had the IVUS appearance of a true or pseudoaneurysm. Instead, most angiographically diagnosed aneurysms had the morphology of complex plaques or normal segments with adjacent stenoses.


Subject(s)
Coronary Aneurysm/diagnostic imaging , Ultrasonography, Interventional , Aged , Aneurysm, False/diagnostic imaging , Constriction, Pathologic , Coronary Aneurysm/pathology , Coronary Angiography , Coronary Artery Disease/pathology , Coronary Vessels/pathology , Dilatation, Pathologic , Female , Humans , Male , Middle Aged
6.
Am J Cardiol ; 88(1): 1-4, 2001 Jul 01.
Article in English | MEDLINE | ID: mdl-11423049

ABSTRACT

Eighty-seven left main stenoses were evaluated by angiography and intravascular ultrasound. Intravascular ultrasound analysis included left main length (bifurcation to ostium), stenosis location, stenosis length, stenosis external elastic membrane, lumen, plaque & media cross-sectional area (CSA), plaque burden (plaque & media/external elastic membrane CSA), calcium arc, calcium length, eccentricity, and remodeling index (stenosis/reference external elastic membrane CSA). Long anatomic left main arteries (length > or =10 mm, n = 43) were compared with short anatomic left main arteries (length <10 mm, n = 44) regarding stenosis location. Ostial (proximal third of left main artery) (n = 32) and nonostial (midthird and distal third) stenoses (n = 55) were compared regarding stenosis morphology. Short anatomic left main arteries developed stenoses more frequently near the ostium (ostium 55%, bifurcation 38%). Conversely, long anatomic left main arteries developed stenoses more frequently near the bifurcation (ostium 18%, bifurcation 77%, p = 0.001). Ostial left main stenoses were more common in women (44% vs 20%, p = 0.02), had larger lumen area (6.2 +/- 2.2 vs 4.6 +/- 2.3 mm(2), p = 0.002), less plaque burden (62 +/- 15% vs 80 +/- 9%, p <0.0001), less calcification (arc = 78 +/- 65 degrees vs 195 +/- 101 degrees, p <0.0001), and more negative remodeling (remodeling index = 0.87 +/- 0.19 vs 1.01 +/- 0.21, p = 0.005) than nonostial left main stenoses. Most ostial left main stenoses were categorized as eccentric (97% vs 76%, p = 0.01). Short and long left main arteries develop stenoses at different locations. Stenosis morphology was significantly different in these 2 locations.


Subject(s)
Coronary Disease/diagnostic imaging , Ultrasonography, Interventional , Aged , Chi-Square Distribution , Coronary Angiography , Coronary Vessels/anatomy & histology , Female , Humans , Image Interpretation, Computer-Assisted , Male , Risk Factors