J Pharm Biomed Anal ; 166: 113-118, 2019 Mar 20.
Article in English | MEDLINE | ID: mdl-30639930

ABSTRACT

A new, rapid, simple and specific method to determine 5-chloro 8-hydroxyquinoline (5-HQ) and 5,7-dichloro 8-hydroxyquinoline (5,7-HQ) stability in swine feed was optimized and validated. A system consisting of an ACQUITY UPLC BEH C18 column (1.7 µm, 2.1 mm × 100 mm), a mobile phase of acetonitrile-0.1% o-phosphoric acid (55:45 v/v) with a 0.5 mL/min flow rate, and a PDA detector (247 nm) were used. The retention times of 5-HQ and 5,7-HQ, were 0.77 min and 1.6 min, respectively. The pure drug was subjected to acid and alkali hydrolysis, chemical oxidation and UV light degradation to perform forced degradation studies. 5,7-HQ was more susceptible to degradation than 5-HQ. The figures of merit of the method (linearity, accuracy, precision, and robustness) were determined. The method was successfully applied to estimate the stability of both analytes in medicated feed.


Subject(s)
Animal Feed/analysis , Chloroquinolinols/analysis , Chromatography, High Pressure Liquid/methods , Chromatography, High Pressure Liquid/instrumentation , Data Accuracy , Drug Stability , Hydrolysis , Oxidation-Reduction , Reproducibility of Results , Ultraviolet Rays
2.
Rapid Commun Mass Spectrom ; 32(19): 1675-1682, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-29964308

ABSTRACT

RATIONALE: Isoprostane 8-iso-PGF2α is a biomarker of lipid peroxidation in cell membranes. The method developed to measure plasma total levels (esterified + free) of 8-iso-PGF2α must be reproducible and be able to reduce the use of solvents in solid phase extraction. It should be useful to evaluate oxidative stress due to the excess of free radicals that are generated by some disorder or disease. METHODS: The method was developed using solid-phase microextraction with Oasis®MAX µElution plates and ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). Electrospray ionization was performed in the negative mode (ESI-); the multiple reaction monitoring mode (MRM) was used. The development of the method included the optimization of the chromatographic conditions to achieve the separation of PGF2α and 8-iso-PGF2α as well as the optimization of the microextraction conditions of the analyte of interest in ovine and goat plasma. RESULTS: The developed method was validated with a calibration curve of plasma samples fortified with standards at five concentration levels in the range 49-639 pg/mL. The average recovery was 89% with a standard deviation of 10.73%. The inter-day precision was evaluated, obtaining a coefficient of variance (CV) less than 15%. The limit of quantification was 20 pg/mL and the limit of detection was 10 pg/mL. 8-iso-PGF2a was determined in the plasma of 14 sheep and 20 goats of 5 months of age and 6 goats of 24 months of age. The concentrations found were 50-300 pg/mL. CONCLUSIONS: The method developed is precise, accurate and reliable with low reagent consumption compared with conventional solid-phase extraction. The analysis time was decreased because, with the use of the microextraction plate, the step of the evaporation and reconstitution of the analyte was avoided. The method is applicable to quantify the plasma total levels (esterified + free) of 8-iso-PGF2α.


Subject(s)
Chromatography, High Pressure Liquid/methods , Dinoprost/analogs & derivatives , Solid Phase Microextraction/methods , Tandem Mass Spectrometry/methods , Animals , Dinoprost/blood , Dinoprost/isolation & purification , Goats , Limit of Detection , Linear Models , Reproducibility of Results , Sheep