1.
Med Phys ; 49(3): 1924-1931, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35023145

ABSTRACT

BACKGROUND AND PURPOSE: In the current and rapidly evolving era of real-time MRI-guided radiotherapy, our radiation biology and dosimetry knowledge is being tested in a novel way. This paper presents the successful design and implementation of a portable device used to generate strong localized magnetic fields. These are ideally suited for small-scale experiments that mimic the magnetic field environment inside an MRI-linac system, or more broadly MRI-guided particle therapy as well. MATERIALS AND METHODS: A portable permanent magnet-based device employing an adjustable steel yoke and magnetic field focusing cones has been designed, constructed, and tested. The apparatus utilizes two banks of Nd 2 $_{2}$ Fe 14 $_{14}$ B permanent magnets totaling around 50 kg in mass to generate a strong magnetic field throughout a small volume between two pole tips. The yoke design allows adjustment of the pole tip gap and exchanging of the focusing cones. Further to this, beam portal holes are present in the yoke and focusing cones, allowing for radiation beams of up to 5 × $\times$ 5 cm 2 $^{2}$ to pass through the region of high magnetic field between the focusing cone tips. Finite element magnetic modeling was performed to design and characterize the performance of the device. Automated physical measurements of the magnetic field components at various locations were measured to confirm the performance. The adjustable pole gap and interchangeable cones allows rapid changing of the experimental set-up to allow different styles of measurements to be performed. RESULTS: A mostly uniform magnetic field of 1.2 T can be achieved over a volume of at least 3 × $\times$ 3 × $\times$ 3 cm 3 $^{3}$ . This can be reduced in strength to 0.3 T but increased in volume to 10 × $\times$ 10 × $\times$ 10 cm 3 $^{3}$ via removal of the cone tips and/or adjustment of the steel yoke. Although small, these volumes are sufficient to house radiation detectors, cell culture dishes, and various phantom arrangements targeted at examining small radiation field dosimetry inside magnetic field strengths that can be changed with ease. Most important is the ability to align the magnetic field both perpendicular to, or inline with, the radiation beam. To date, the system has been successfully used to conduct published research in the areas of radiation detector performance, lung phantom dosimetry, and how small clinical electron beams behave in these strong magnetic fields. CONCLUSIONS: A portable, relatively inexpensive, and simple to operate device has successfully been constructed and used for performing radiation oncology studies around the theme of MRI-guided radiotherapy. This can be in either inline and perpendicular magnetic fields of up to 1.2 T with x-ray and particle beams.


Subject(s)
Magnetic Fields , Magnets , Magnetic Resonance Imaging , Particle Accelerators , Radiobiology , Radiometry
2.
Med Phys ; 47(1): 181-189, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31621914

ABSTRACT

PURPOSE: To report on experimental results of a high spatial resolution silicon-based detector exposed to therapeutic quality proton beams in a 0.95 T transverse magnetic field. These experimental results are important for the development of accurate and novel dosimetry methods in future potential real-time MRI-guided proton therapy systems. METHODS: A permanent magnet device was utilized to generate a 0.95 T magnetic field over a 4 × 20 × 15 cm3 volume. Within this volume, a high-resolution silicon diode array detector was positioned inside a PMMA phantom of 4 × 15 × 12 cm3 . This detector contains two orthogonal strips containing 505 sensitive volumes spaced at 0.2 mm apart. Proton beams collimated to a circle of 10 mm diameter with nominal energies of 90 MeV, 110 MeV, and 125 MeV were incident on the detector from an edge-on orientation. This allows for a measurement of the Bragg peak at 0.2 mm spatial resolution in both the depth and lateral profile directions. The impact of the magnetic field on the proton beams, that is, a small deflection was also investigated. A Geant4 Monte Carlo simulation was performed of the experimental setup to aid in interpretation of the results. RESULTS: The nominal Bragg peak for each proton energy was successfully observed with a 0.2 mm spatial resolution in the 0.95 T transverse magnetic field in both a depth and lateral profiles. The proton beam deflection (at 0.95 T) was a consistent 2 ±0.5 mm at the center of the magnetic volume for each beam energy. However, a pristine Bragg peak was not observed for each energy. This was caused by the detector packaging having small air gaps between layers of the phantom material surrounding the diode array. These air gaps act to degrade the shape of the Bragg peak, and further to this, the nonwater equivalent silicon chip acts to separate the Bragg peak into multiple peaks depending on the proton path taken. Overall, a promising performance of the silicon detector array was observed, however, with a qualitative assessment rather than a robust quantitative dosimetric evaluation at this stage of development. CONCLUSIONS: For the first time, a high-resolution silicon-based radiation detector has been used to measure proton beam Bragg peak deflections in a phantom due to a strong magnetic field. Future efforts are required to optimize the detector packaging to strengthen the robustness of the dosimetric quantities obtained from the detector. Such high-resolution silicon diode arrays may be useful in future efforts in MRI-guided proton therapy research.


Subject(s)
Magnetic Fields , Proton Therapy/instrumentation , Radiometry/instrumentation , Silicon , Signal-To-Noise Ratio
3.
Radiother Oncol ; 125(3): 433-438, 2017 12.
Article in English | MEDLINE | ID: mdl-28985954

ABSTRACT

BACKGROUND AND PURPOSE: To present experimental evidence of lung dose enhancement effects caused by strong inline magnetic fields. MATERIALS AND METHODS: A permanent magnet device was utilised to generate 0.95T-1.2T magnetic fields that encompassed two small lung-equivalent phantoms of density 0.3g/cm3. Small 6MV and 10MV photon beams were incident parallel with the magnetic field direction and Gafchromic EBT3 film was placed inside the lung phantoms, perpendicular to the beam (experiment 1) and parallel to the beam (experiment 2). Monte Carlo simulations of experiment 1 were also performed. RESULTS: Experiment 1: The 1.2T inline magnetic field induced a 12% (6MV) and 14% (10MV) increase in the dose at the phantom centre. The Monte Carlo modelling matched well (±2%) to the experimentally observed results. Experiment 2: A 0.95T field peaked at the phantom centroid (but not at the phantom entry/exit regions) details a clear dose increase due to the magnetic field of up to 25%. CONCLUSIONS: This experimental work has demonstrated how strong inline magnetic fields act to enhance the dose to lower density mediums such as lung tissue. Clinically, such scenarios will arise in inline MRI-linac systems for treatment of small lung tumours.


Subject(s)
Lung Neoplasms/radiotherapy , Magnetic Fields , Magnetic Resonance Imaging/methods , Radiotherapy, Image-Guided/methods , Humans , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage