Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anaesthesia ; 73(8): 967-971, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29727012

ABSTRACT

Arm-crank ergometry may be useful in patients unable to pedal, for instance due to peripheral arterial disease. Twenty participants with small abdominal aortic aneurysm undertook two serial arm-crank tests and then a pedal test, four of whom had indeterminate anaerobic thresholds, precluding analysis. The mean (SD) peak arm and leg oxygen consumptions in 16 participants were 13.71 (2.62) ml.kg-1 .min-1 and 16.82 (4.44) ml.kg-1 .min-1 , with mean (SD) individual differences of 3.11 (2.48) ml.kg-1 .min-1 , p = 0.0001. The respective values at the anaerobic thresholds were 7.83 (1.58) ml O2 .kg-1 .min-1 and 10.09 (3.15) ml O2 .kg-1 .min-1 , with mean (SD) individual differences of 2.26 (2.34) ml O2 .kg-1 .min-1 , p = 0.0001. The correlation coefficients (95%CI) for peak oxygen consumption and anaerobic threshold were 0.88 (0.62-1.0) and 0.70 (0.32-1.0). There were no significant differences in serial arm-crank tests, with intracluster correlations (95%CI) of 0.87 (0.86-0.88) and 0.65 (0.61-0.69) for peak oxygen consumption and anaerobic threshold, respectively.


Subject(s)
Aortic Aneurysm, Abdominal/physiopathology , Exercise Test/methods , Aged , Aged, 80 and over , Anaerobic Threshold , Aortic Aneurysm, Abdominal/diagnosis , Arm/anatomy & histology , Female , Humans , Leg/anatomy & histology , Male , Middle Aged , Oxygen Consumption , Reproducibility of Results
2.
Br J Anaesth ; 108(1): 30-5, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21980122

ABSTRACT

BACKGROUND: For perioperative risk stratification, a robust, practical test could be used where cardiopulmonary exercise testing (CPET) is unavailable. The aim of this study was to assess the utility of the 6 min walk test (6MWT) distance to discriminate between low and high anaerobic threshold (AT) in patients awaiting major non-cardiac surgery. METHODS: In 110 participants, we obtained oxygen consumption at the AT from CPET and recorded the distance walked (in m) during a 6MWT. Receiver operating characteristic (ROC) curve analysis was used to derive two different cut-points for 6MWT distance in predicting an AT of <11 ml O(2) kg(-1) min(-1); one using the highest sum of sensitivity and specificity (conventional method) and the other adopting a 2:1 weighting in favour of sensitivity. In addition, using a novel linear regression-based technique, we obtained lower and upper cut-points for 6MWT distance that are predictive of an AT that is likely to be (P≥0.75) <11 or >11 ml O(2) kg(-1) min(-1). RESULTS: The ROC curve analysis revealed an area under the curve of 0.85 (95% confidence interval, 0.77-0.91). The optimum cut-points were <440 m (conventional method) and <502 m (sensitivity-weighted approach). The regression-based lower and upper 6MWT distance cut-points were <427 and >563 m, respectively. CONCLUSIONS: Patients walking >563 m in the 6MWT do not routinely require CPET; those walking <427 m should be referred for further evaluation. In situations of 'clinical uncertainty' (≥427 but ≤563 m), the number of clinical risk factors and magnitude of surgery should be incorporated into the decision-making process. The 6MWT is a useful clinical tool to screen and risk stratify patients in departments where CPET is unavailable.


Subject(s)
Anaerobic Threshold , Exercise Test/methods , Preoperative Care , Surgical Procedures, Operative/methods , Walking/physiology , Aged , Aged, 80 and over , Area Under Curve , Carbon Dioxide/blood , Female , Heart Rate/physiology , Humans , Male , Middle Aged , Oxygen Consumption/physiology , Predictive Value of Tests , ROC Curve , Regression Analysis , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...