Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 37(8): 4038-45, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20879565

ABSTRACT

PURPOSE: To study the effects of the breast-air and breast-lung interfaces on the absorbed dose within the planning target volume (PTV) of a MammoSite balloon dose delivery system as well as the effect of contrast material on the dose rate in the PTV. METHODS: The Monte Carlo MCNP5 code was used to simulate dose rate in the PTV of a 2 cm radius MammoSite balloon dose delivery system. The simulations were carried out using an average female chest phantom (AFCP) and a semi-infinite water phantom for both Yb-169 and Ir-192 high dose rate sources for brachytherapy application. Gastrografin was introduced at varying concentrations to study the effect of contrast material on the dose rate in the PTV. RESULTS: The effect of the density of the materials surrounding the MammoSite balloon containing 0% contrast material on the calculated dose rate at different radial distances in the PTV was demonstrated. Within the PTV, the ratio of the calculated dose rate for the AFCP and the semi-infinite water phantom for the point closest to the breast-air interface (90 degrees) is less than that for the point closest to the breast-lung interface (270 degrees) by 11.4% and 4% for the HDR sources of Yb-169 and Ir-192, respectively. When contrast material was introduced into the 2 cm radius MammoSite balloon at varying concentrations, (5%, 10%, 15%, and 20%), the dose rate in the AFCP at 3.0 cm radial distance at 90 degrees was decreased by as much as 14.8% and 6.2% for Yb-169 and Ir-192, respectively, when compared to that of the semi-infinite water phantom with contrast concentrations of 5%, 10%, 15%, and 20%, respectively. CONCLUSIONS: Commercially available software used to calculate dose rate in the PTV of a MammoSite balloon needs to account for patient anatomy and density of surrounding materials in the dosimetry analyses in order to avoid patient underdose.


Subject(s)
Brachytherapy/instrumentation , Breast Neoplasms/physiopathology , Breast Neoplasms/radiotherapy , Catheterization , Iridium Radioisotopes/therapeutic use , Lung/physiopathology , Models, Biological , Radiotherapy Planning, Computer-Assisted/methods , Ytterbium/therapeutic use , Air , Computer Simulation , Female , Humans , Radiation Dosage , Radiotherapy Dosage
2.
Med Phys ; 37(3): 1129-36, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20384248

ABSTRACT

PURPOSE: The objective was to characterize a new Yb-169 high dose rate source for brachytherapy application. METHODS: Monte Carlo simulations were performed using the MCNP5 F6 energy deposition tallies placed around the Yb-169 source at different radial distances in both air-vacuum and water environments. The calculations were based on a spherical water phantom with a radius of 50 cm. The output from the simulations was converted into radial dose rate distribution in polar coordinates surrounding the brachytherapy source. RESULTS: The results from Monte Carlo simulations were used to calculate the AAPM Task Group 43 dosimetric parameters: Anisotropy function, radial dose function, air kerma strength, and dose rate constant. The results indicate a dose rate constant of 1.12 +/- 0.04 cGy h(-1) U(-1), anisotropy function ranging from 0.44 to 1.00 for radial distances of 0.5-10 cm and polar angles of 0 degrees-180 degrees. CONCLUSIONS: The data from the Yb-169 HDR source, Model M42, presented in this study show that this source compares favorably with another source of Yb-169, Model 4140, already approved for brachytherapy treatment.


Subject(s)
Brachytherapy/instrumentation , Models, Biological , Monte Carlo Method , Radioisotopes/therapeutic use , Radiometry/methods , Ytterbium/therapeutic use , Computer Simulation , Equipment Design , Equipment Failure Analysis , Humans , Models, Statistical , Radioisotopes/analysis , Radiotherapy Dosage , Ytterbium/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...