Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
3.
AJR Am J Roentgenol ; 186(6): 1551-9, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16714643

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the clinical value and potential impact of SonoVue-enhanced sonography in the characterization of focal liver lesions. SUBJECTS AND METHODS: This study included 127 patients with 82 malignant and 52 benign lesions in the liver. Contrast-enhanced sonography was performed using nonlinear imaging modes at low mechanical index (0.1-0.3) to enable real-time visualization of arterial, portal, and late-phase enhancement. Digital recordings of unenhanced sonography and contrast-enhanced sonography were reviewed by on-site investigators and two off-site blinded interpreters. The final diagnosis was based on consensus interpreting of all examinations by another two expert observers with access to CT, MRI, and histologic data; the diagnostic accuracy of contrast-enhanced sonography in identifying the lesion as benign, malignant, or indeterminate and as actual tumor type was compared with baseline sonography. RESULTS: For on-site investigators, contrast-enhanced sonography reduced the number of indeterminate diagnoses by 67% and improved the sensitivity and specificity to 90.2% and 80.8%, respectively (p < 0.001). For off-site interpreters, contrast-enhanced sonography reduced the number of indeterminate diagnoses by 51-56% (p < 0.001); significantly improved sensitivity and specificity to 90.8-95.4% and 83.7-89.8%, respectively (p < 0.001); eliminated observers' variability (kappa coefficient: 0.66-0.77); and showed no significant difference in all comparisons in the analysis of lesions measuring less than 1.5 cm, 1.5-2.5 cm, and all sizes combined. Contrast-enhanced sonography did not rely on availability of clinical history to enable the diagnoses, and it reduced the need for further imaging investigations 23.7% to 90.4%. CONCLUSION: Contrast-enhanced sonography improves the characterization of focal liver lesions and may limit the need for further investigations.


Subject(s)
Contrast Media , Image Enhancement , Liver Neoplasms/diagnostic imaging , Phospholipids , Sulfur Hexafluoride , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Ultrasonography
4.
Ann Surg ; 243(2): 236-40, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16432357

ABSTRACT

OBJECTIVE: The aim of the study was to assess the clinical value of contrast-enhanced intraoperative ultrasound (CE-IOUS) as a novel tool in the hepatic staging of patients undergoing liver resection. METHODS: Sixty patients scheduled to undergo liver resection for metastatic disease were studied. Preoperative staging with contrast-enhanced CT and/or MR scans was performed within 2 to 6 weeks of operation. Following exploration, intraoperative ultrasound (IOUS) was performed using an HDI-5000 scanner (Philips) and a finger-probe with pulse inversion harmonic (PIH) capability. CE-IOUS in the PIH mode was performed in a standardized protocol (low MI: 0.02-0.04) after intravenous injection of 3-4 mL of SonoVue (Bracco spa, Milan); all detected lesions on precontrast and postcontrast scans were counted and mapped. Any alteration in surgical management was documented following CE-IOUS compared with IOUS. RESULTS: Three patients were excluded due to disseminated disease on exploration. CE-IOUS was significantly more sensitive than CT/MR and IOUS in detecting liver metastases (96.1% versus 76.7% and 81.5%, respectively) (P<0.05); it altered surgical management in 29.8% (17 of 57) of cases, due to 1) additional metastases in 19.3% (11 of 57), 2) less metastases in 3.5% (2 of 57), 3) benign lesions wrongly diagnosed as metastasis on IOUS/CT in 5.3% (3 of 57), and 4) vascular proximity in 1.8% (1 of 57). Management was unchanged in 70.2% (40 of 57) despite additional lesions detected in 3.5% (2 of 57) and benign lesion wrongly diagnosed on IOUS and CT as metastasis in 1.8% (1 of 57). CE-IOUS altered combined IOUS/CT/MR staging in 35.1%. CONCLUSION: These preliminary results suggest CE-IOUS is an essential tool prior to liver resection for metastases.


Subject(s)
Contrast Media , Hepatectomy/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Monitoring, Intraoperative , Neoplasm Metastasis/diagnostic imaging , Neoplasm Staging/methods , Phospholipids , Sulfur Hexafluoride , Adult , Aged , Aged, 80 and over , Female , Humans , Liver Neoplasms/secondary , Magnetic Resonance Imaging , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity , Statistics, Nonparametric , Tomography, X-Ray Computed , Treatment Outcome , Ultrasonography
5.
J Ultrasound Med ; 23(9): 1171-6, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15328431

ABSTRACT

OBJECTIVE: To evaluate the role of sonographically guided small-bore chest catheters and sonographically based monitoring of fluid evacuation in rapid sclerotherapy of malignant pleural effusions. METHODS: In 50 patients with recurrent malignant pleural effusions, a 9F catheter was inserted into the pleural space under sonographic guidance. When sonography documented complete fluid evacuation, bleomycin (0.75 mg/kg) was injected via the tube. Fluid drainage was monitored for 12 hours; if fluid output was less than 100 mL, the pleural catheter was removed; otherwise, a second dose of bleomycin was administered after 24 hours. If loculations or fluid reaccumulations due to tube malfunctioning were detected, they were evacuated by sonographically guided thoracentesis, and bleomycin (1.5 mg/100 mL of fluid) was injected through the thoracentesis needle. All patients were monitored for fluid recurrence with thoracic sonography. RESULTS: Twenty-nine patients received 1 dose of bleomycin, and 21 received 2 doses. In 11 patients with residual loculations, sonographically guided thoracentesis was performed, and bleomycin was injected into the loculations. In 29 patients, pleurodesis was completed within 24 hours; in 21, it was completed within 48 hours. The 30-day response was 84%; the long-term response was 60%. No complications or serious side effects were observed. CONCLUSIONS: Rapid pleurodesis can be accomplished within 24 to 48 hours, with good short- and long-term responses. Thoracic sonography plays a pivotal role. It guides placement of the pleural catheter and is valuable in the monitoring of fluid evacuation for determining the right time for sclerosing agent administration and in the detection and treatment of loculations or residual pleural fluid due to tube malfunctioning.


Subject(s)
Chest Tubes , Neoplasm Recurrence, Local/therapy , Pleural Effusion, Malignant/diagnostic imaging , Pleural Effusion, Malignant/therapy , Pleurodesis , Sclerotherapy , Adult , Aged , Drainage , Equipment Design , Female , Humans , Male , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Neoplasms, Multiple Primary , Prospective Studies , Ultrasonography
6.
J Clin Oncol ; 22(7): 1228-33, 2004 Apr 01.
Article in English | MEDLINE | ID: mdl-15051770

ABSTRACT

PURPOSE: To compare bleomycin pleurodesis and immunotherapy with intrapleural interferon alfa-2b (IFN) in the palliation of malignant pleural effusions. PATIENTS AND METHODS: One hundred sixty patients with rapidly recurrent malignant pleural effusion were randomly assigned to intrapleural bleomycin (83 patients) or IFN (77 patients). A 9-French intrapleural catheter was placed under sonographic guidance, and pleural effusion was completely drained before starting the treatment. Bleomycin 0.75 mg/kg was administered as a single dose. An additional dose was given if daily fluid output did not drop to less than 100 mL/d within 3 days. IFN 1 million units/10 kg was administered for six courses at 4-day intervals. Thirty-day and long-term responses were evaluated under the intention-to-treat principle. RESULTS: Thirty-day response was 84.3% in the bleomycin arm and 62.3% in IFN arm (P =.002). Median time to progression was 93 days (range, 12 to 395 days) in bleomycin group, and 59 days (range, 7 to 292 days) in the IFN group (P <.001). Median survival was 96 days (range, 15 to 395) and 85 days (range, 16 to 292) in the bleomycin and IFN groups, respectively. Twenty-three patients received two doses of bleomycin, as their daily fluid output remained higher than 100 mL after the first dose. Thirteen of them had complete response, which lasted until death. CONCLUSION: Intrapleural bleomycin is more effective than IFN and is a valid option for the palliative treatment of massive, rapidly recurrent malignant pleural effusions. The administration of a second dose of bleomycin to patients not responding to the first one can remarkably improve the overall outcome of the treatment.


Subject(s)
Antineoplastic Agents/administration & dosage , Bleomycin/administration & dosage , Interferon-alpha/administration & dosage , Pleural Effusion, Malignant/drug therapy , Pleurodesis , Adult , Aged , Aged, 80 and over , Catheterization , Chest Tubes , Female , Humans , Instillation, Drug , Interferon alpha-2 , Male , Middle Aged , Palliative Care , Pleural Effusion, Malignant/diagnostic imaging , Prospective Studies , Recombinant Proteins , Treatment Outcome , Ultrasonography
9.
J Ultrasound Med ; 21(9): 1035-9, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12216751

ABSTRACT

OBJECTIVE: To report 2 cases in which abdominal sonography played a useful role in diagnosing sarcoidosis with early nodular hepatosplenic manifestations. METHODS: In the first case, an asymptomatic woman with increased liver enzyme values underwent sonography, which showed multiple hypoechoic nodules in the liver and spleen. Computed tomography confirmed the hepatosplenic findings and showed micronodular infiltrates of both lung fields, without hilar and mediastinal lymphadenopathy. In the second case, in a woman with a cough, dyspnea, and increased liver enzyme levels, thoracic computed tomography showed right pleural effusion causing partial atelectasis of the lower and middle lobes and mediastinal lymphadenopathy. RESULTS: Sonography and computed tomography showed multiple nodules of the liver and spleen and retroperitoneal lymphadenopathy. In both cases, bronchoscopy, bronchial and bronchioloalveolar lavages, and transbronchial and mediastinal biopsies had negative results. Sonographically guided biopsy of the hepatic nodules was carried out and sarcoid granulomas were detected in the portal areas. After 3 months of steroid therapy, liver enzyme values nearly normalized, and sonography showed the disappearance of all abdominal lesions. The first patient underwent control computed tomography, which confirmed the regression of the disease; the second patient refused control computed tomography. CONCLUSIONS: Sarcoidosis can occur with atypical onset, and in selected cases sonography may play a useful role in its diagnosis and follow-up.


Subject(s)
Liver Diseases/diagnostic imaging , Sarcoidosis/diagnostic imaging , Splenic Diseases/diagnostic imaging , Anti-Inflammatory Agents/therapeutic use , Biopsy, Needle/methods , Female , Glucocorticoids/therapeutic use , Humans , Liver Diseases/drug therapy , Liver Diseases/pathology , Middle Aged , Pleural Effusion/diagnostic imaging , Pleural Effusion/etiology , Prednisone/therapeutic use , Pregnenediones/therapeutic use , Sarcoidosis/drug therapy , Sarcoidosis/pathology , Splenic Diseases/drug therapy , Splenic Diseases/pathology , Tomography, X-Ray Computed , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...