Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
J Atmos Chem ; 72(3-4): 261-286, 2015.
Article in English | MEDLINE | ID: mdl-26692593

ABSTRACT

Total-column nitrogen dioxide (NO2) data collected by a ground-based sun-tracking spectrometer system (Pandora) and an photolytic-converter-based in-situ instrument collocated at NASA's Langley Research Center in Hampton, Virginia were analyzed to study the relationship between total-column and surface NO2 measurements. The measurements span more than a year and cover all seasons. Surface mixing ratios are estimated via application of a planetary boundary-layer (PBL) height correction factor. This PBL correction factor effectively corrects for boundary-layer variability throughout the day, and accounts for up to ≈75 % of the variability between the NO2 data sets. Previous studies have made monthly and seasonal comparisons of column/surface data, which has shown generally good agreement over these long average times. In the current analysis comparisons of column densities averaged over 90 s and 1 h are made. Applicability of this technique to sulfur dioxide (SO2) is briefly explored. The SO2 correlation is improved by excluding conditions where surface levels are considered background. The analysis is extended to data from the July 2011 DISCOVER-AQ mission over the greater Baltimore, MD area to examine the method's performance in more-polluted urban conditions where NO2 concentrations are typically much higher.

2.
Photochem Photobiol Sci ; 8(4): 516-27, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19337666

ABSTRACT

A variety of instruments have been developed over the past 50 years to measure spectral radiance in absolute units at UV and visible wavelengths with high spectral resolution. While there is considerable experience in the measurement of spectral irradiance, less emphasis has been given to the reliable measurement of spectral radiance from ground observations. We discuss the methodology and calibration procedures for five instruments capable of making such measurements. Four of these instruments are based on double monochromators that scan each wavelength in turn, and one is based on a single monochromator with a charged coupled device (CCD) allowing the recording of all wavelengths simultaneously. The measured spectral radiance deviates between 3% and about 35% depending on the instruments. The results are compared with radiative transfer calculations when the aerosol characteristics of the atmosphere are known.


Subject(s)
Meteorology/methods , Atmosphere , Calibration/standards , Germany , Radiation Dosage , Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Spectrophotometry/instrumentation , Spectrophotometry/methods , Spectrophotometry, Ultraviolet/instrumentation , Spectrophotometry, Ultraviolet/methods , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...