Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Revasc Med ; 52: 10-15, 2023 07.
Article in English | MEDLINE | ID: mdl-36822976

ABSTRACT

INTRODUCTION AND OBJECTIVE: At least one in ten patients infected with COVID develop cardiovascular complications during hospitalization, increasing the number of deaths from this cause. However, the determinants of risk are not clearly elucidated. This study aims to determine whether there is a relationship between in-hospital cardiac complications and cardiovascular history and hospital evolution. METHODS: Prospective cohort study of 373 patients with a positive diagnosis of SARS-CoV-2 admitted to an Intensive Care Unit between March and October 2021. RESULTS: Median age was 69 (IQR: 57-77), 29.2 % of patients presented cardiovascular complications: 21.2 % electrical, 5.9 % acute coronary syndrome and 1.9 % pulmonary thromboembolism. Age RR: 1.02 (95 % CI: 1.00-1.04; p = 0.020) and history of ischemic heart disease RR: 2.23 (95 % CI: 1.27-3.92; p = 0.005) were identified as independent predictors of in-hospital cardiac complications. CONCLUSIONS: Age and history of ischemic heart disease were identified as independent predictor variables of cardiovascular complications in patients admitted with severe COVID-19 involvement; being significantly associated with lower survival.


Subject(s)
COVID-19 , Heart Diseases , Myocardial Ischemia , Humans , Aged , COVID-19/complications , COVID-19/diagnosis , SARS-CoV-2 , Cohort Studies , Prospective Studies , Cuba/epidemiology , Hospitalization , Myocardial Ischemia/diagnosis , Myocardial Ischemia/epidemiology , Risk Factors , Hospital Mortality
2.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Article in English | MEDLINE | ID: mdl-36093795

ABSTRACT

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Heart Valve Prosthesis/adverse effects , Postoperative Complications/etiology , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...