Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Trials ; 25(1): 324, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755709

ABSTRACT

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Subject(s)
Aortic Valve , Aspirin , Factor Xa Inhibitors , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Aged , Female , Humans , Male , Middle Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aspirin/administration & dosage , Aspirin/therapeutic use , Aspirin/adverse effects , Bioprosthesis , Factor Xa Inhibitors/administration & dosage , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Fibrinolytic Agents/administration & dosage , Fibrinolytic Agents/adverse effects , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Prospective Studies , Pyrazoles/therapeutic use , Pyrazoles/administration & dosage , Pyrazoles/adverse effects , Pyridones/therapeutic use , Pyridones/administration & dosage , Pyridones/adverse effects , Randomized Controlled Trials as Topic , Thrombosis/prevention & control , Thrombosis/etiology , Time Factors , Treatment Outcome
2.
Heart Surg Forum ; 26(1): E038-E039, 2023 Jan 31.
Article in English | MEDLINE | ID: mdl-36856506

ABSTRACT

A 44-year-old female patient with chemotherapy-induced cardiomyopathy presented with acute cardiogenic shock requiring ECMO support. Multiple failed weaning trials from temporary mechanical circulatory assistance prompted a transition to staged durable biventricular support. Her course was complicated with recurrent RVAD stoppages. The initial event was treated with pump exchange, while for the subsequent RVAD standstill, we employed a device wash-out and reimplantation strategy. A brief period of circulatory arrest was employed to explore the right-sided cardiac chambers using a single-use bronchoscope.


Subject(s)
Dextrocardia , Heart Arrest , Heart-Assist Devices , Humans , Female , Adult , Shock, Cardiogenic
3.
Croat Med J ; 63(5): 423-430, 2022 Oct 31.
Article in English | MEDLINE | ID: mdl-36325666

ABSTRACT

AIM: To evaluate the impact of minimally invasive aortic valve replacement (mini-AVR) on clinical outcomes in comparison with the gold standard. METHODS: We retrospectively reviewed the records of all patients who underwent isolated AVR at the University Hospital Center Zagreb from 2010 to 2020. Patients undergoing mini-AVR were compared with patients undergoing conventional AVR (fs-AVR). The primary outcome measure was blood product consumption. Propensity score matching was used to create a balanced covariate distribution across treatment groups. Additionally, we compared the contemporary outcomes with a historical control. RESULTS: The final sample consisted of 1088 patients. In the unmatched cohorts, mini-AVR patients were younger (65±12 vs 68±10 years, P<0.001) and had lower risk profiles (EuroSCORE2 2.8±2.0 vs 3.5±3.1, P=0.003). After matching, mini-AVR patients required less blood transfusion than fs-AVR patients (270 [0-790] vs 510 [0-970] mL, P=0.029). The incidences of stroke, dialysis, new AV block, and mortality were comparable. Cross-clamp times were longer in the mini-AVR group (71 [60-87] vs 66 [53-83] minutes, P=0.013). Outcomes were improved in the contemporary mini-AVR era compared with our early mini-AVR experience across multiple metrics. Blood product consumption was reduced in the latter tercile of experience (0 [0-520] vs 500 [0-1018] mL, P<0.001), and the operation was performed more expeditiously (cross-clamp times: 63 [54,80] vs 74 [62,88] minutes, P<0.001) in comparison with earlier periods. CONCLUSIONS: We showed that mini-AVR was associated with less blood product requirement than conventional surgery. Our data supports wider adoption of minimally invasive techniques in dedicated centers of excellence.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/surgery , Propensity Score , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Sternotomy/methods , Treatment Outcome , Minimally Invasive Surgical Procedures/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...