1.
Dent J (Basel) ; 11(10)2023 Sep 24.
Article in English | MEDLINE | ID: mdl-37886912

ABSTRACT

BACKGROUND: Macro-geometry and surgical implant site preparation are two of the main factors influencing implant stability and potentially determining loading protocol. The purpose of this study was to assess the initial stability of various implant macro-designs using both magnetodynamic and traditional osteotomy techniques in low-density bone. The parameters examined included peak insertion torque (PIT), implant stability quotient (ISQ), and peak removal torque (PRT). METHODS: Four groups of 34 implants each were identified in accordance with the surgery and implant shape: T5 group (Five implant and osteotomy using drills); M5 group (Five implant and magnetodynamic osteotomy using Magnetic Mallet); TT group (TiSmart implant and osteotomy with drills); and MT group (TiSmart implant and magnetodynamic osteotomy). Every implant was placed into a low-density bone animal model and scanned using CBCT. The PIT and PRT were digitally measured in Newton-centimeters (Ncm) using a torque gauge device. The ISQ was analyzed by conducting resonance frequency analysis. RESULTS: The PIT values were 25.04 ± 4.4 Ncm for T5, 30.62 ± 3.81 Ncm for M5, 30 ± 3.74 Ncm for TT, and 32.05 ± 3.55 Ncm for MT. The average ISQ values were 68.11 ± 3.86 for T5, 71.41 ± 3.69 for M5, 70.88 ± 3.08 for TT, and 73 ± 3.5 for MT. The PRT values were 16.47 ± 4.56 Ncm for T5, 26.02 ± 4.03 Ncm for M5, 23.91 ± 3.28 Ncm for TT, and 26.93 ± 3.96 Ncm for MT. Based on our data analysis using a t-test with α = 0.05, significant differences in PIT were observed between TT and T5 (p < 0.0001), M5 and T5 (p < 0.0001), and MT and TT (p = 0.02). Significant differences in the ISQ were found between TT and T5 (p = 0.001), M5 and T5 (p < 0.001), and MT and TT (p = 0.01). The PRT also exhibited significant differences between TT and T5, M5 and T5, and MT and TT (p < 0.0001). CONCLUSION: Our data showed favorable primary implant stability (PS) values for both implant macro-geometries. Furthermore, the magnetodynamic preparation technique appears to be more effective in achieving higher PS values in low-density bone.

2.
Dent J (Basel) ; 11(6)2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37366670

ABSTRACT

In the present case-control study, the impact of medication-related osteonecrosis of the jaws (MRONJ) on patients' oral health-related quality of life (OHRQoL), overall quality of life (QoL), and psychological status was evaluated using a set of questionnaires. These questionnaires included the Oral Health Impact Profile-14 (OHIP-14), the Short Form 36 Health Survey Questionnaire (SF-36), and the hospital anxiety and depression scale (HADS). A total of 25 MRONJ patients and 25 controls were included in the study. The results showed that MRONJ patients had a significantly poorer OHRQoL (OHIP-14 score p-value: 0.003) and lower general QoL, particularly in the domains of "physical functioning", "physical role", "body pain", "general health", and "vitality" in the SF-36 questionnaire (p-values: 0.001, 0.001, 0.013, 0.001, and 0.020). Although there were no significant differences between the groups in the SF-36 domains of "social functioning", "emotional role", and "mental health", the mean sub-scores of the HADS, specifically the depression and anxiety scores (HADS-D and HADS-A), were significantly higher in MRONJ patients (p-values: 0.002 and 0.009). However, the "mental health" domain of the SF-36 questionnaire showed a correlation with both HADS-A and HADS-D scores (p-values: 0.003 and 0.031). Therefore, a comprehensive clinical examination of MRONJ patients should include the assessment of OHRQoL, overall QoL, and psychological profile using different questionnaires. This approach aims to gather detailed information about patients' physical and psychological well-being, enabling the development of tailored treatments.

SELECTION OF CITATIONS
SEARCH DETAIL
...