Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Radiography (Lond) ; 27(2): 519-526, 2021 05.
Article in English | MEDLINE | ID: mdl-33272825

ABSTRACT

INTRODUCTION: Clinical evaluation of deep learning (DL) tools is essential to compliment technical accuracy metrics. This study assessed the image quality of standard fetal head planes automatically-extracted from three-dimensional (3D) ultrasound fetal head volumes using a customised DL-algorithm. METHODS: Two observers retrospectively reviewed standard fetal head planes against pre-defined image quality criteria. Forty-eight images (29 transventricular, 19 transcerebellar) were selected from 91 transabdominal fetal scans (mean gestational age = 26 completed weeks, range = 20+5-32+3 weeks). Each had two-dimensional (2D) manually-acquired (2D-MA), 3D operator-selected (3D-OS) and 3D-DL automatically-acquired (3D-DL) images. The proportion of adequate images from each plane and modality, and the number of inadequate images per plane was compared for each method. Inter and intra-observer agreement of overall image quality was calculated. RESULTS: Sixty-seven percent of 3D-OS and 3D-DL transventricular planes were adequate quality. Forty-five percent of 3D-OS and 55% of 3D-DL transcerebellar planes were adequate. Seventy-one percent of 3D-OS and 86% of 3D-DL transventricular planes failed with poor visualisation of intra-cranial structures. Eighty-six percent of 3D-OS and 80% of 3D-DL transcerebellar planes failed due to inadequate visualisation of cerebellar hemispheres. Image quality was significantly different between 2D and 3D, however, no significant difference between 3D-modalities was demonstrated (p < 0.005). Inter-observer agreement of transventricular plane adequacy was moderate for both 3D-modalities, and weak for transcerebellar planes. CONCLUSION: The 3D-DL algorithm can automatically extract standard fetal head planes from 3D-head volumes of comparable quality to operator-selected planes. Image quality in 3D is inferior to corresponding 2D planes, likely due to limitations with 3D-technology and acquisition technique. IMPLICATIONS FOR PRACTICE: Automated image extraction of standard planes from US-volumes could facilitate use of 3DUS in clinical practice, however image quality is dependent on the volume acquisition technique.


Subject(s)
Imaging, Three-Dimensional , Ultrasonography, Prenatal , Female , Gestational Age , Head/diagnostic imaging , Humans , Infant, Newborn , Pregnancy , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...