Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Appl Radiat Isot ; 67(7-8 Suppl): S157-60, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19410468

ABSTRACT

The evaluation of possible improvement in the use of Gd in cancer therapy, in reference to gadolinium in cancer therapy (GdNCT), has been analysed. At first the problem of the gadolinium compounds toxicity was reviewed identifying the Motexafin Gadolinium as the best. Afterwards, the spectrum of IC and Auger electrons was calculated using a special method. Afterwards, this electron source has been used as input of the PENELOPE code and the energy deposit in DNA was well defined. Taking into account that the electron yield and energy distribution are related to the neutron beam spectrum and intensity, the shaping assembly architecture was optimised through computational investigations. Finally the study of GdNCT was performed from two different points of view: macrodosimetry using MCNPX, with calculation of absorbed doses both in tumour and healthy tissues, and microdosimetry using PENELOPE, with the determination of electron RBE through the energy deposit. The equivalent doses were determined combining these two kinds of data, introducing specific figures of merit to be used in treatment planning system (TPS). According to these results, the GdNCT appears to be a fairly possible tumour therapy.


Subject(s)
Gadolinium/therapeutic use , Neoplasms/radiotherapy , Neutron Capture Therapy/methods , Radiation-Sensitizing Agents/therapeutic use , Gadolinium/pharmacokinetics , Gadolinium/toxicity , Humans , Isotopes/pharmacokinetics , Isotopes/therapeutic use , Isotopes/toxicity , Monte Carlo Method , Neutron Capture Therapy/statistics & numerical data , Neutron Capture Therapy/trends , Radiation-Sensitizing Agents/pharmacokinetics , Radiation-Sensitizing Agents/toxicity , Radiotherapy Planning, Computer-Assisted/statistics & numerical data
2.
Radiat Prot Dosimetry ; 115(1-4): 122-5, 2005.
Article in English | MEDLINE | ID: mdl-16381696

ABSTRACT

The management of radioactive waste is a key issue for the present and future use of nuclear energy. In this frame, high temperature reactors (HTRs) have, among others, the capability to burn actinides. After a short introduction on HTRs, the performances of two MC-based burnup codes (Monte Carlo continuous energy burnup and MONTEBURNS) in assessing the ability of these reactors to burn actinides are compared. These codes are necessary for performing ultra-high burnup calculations on HTRs. The best one, in this specific case, results to be MONTEBURNS. It was analysed using HTRs loaded with the following: (1) 1st generation Pu, 600 equivalent full power days; (2) 2nd generation Pu, 645 equivalent full power days; and (iii) 33% 1st generation Pu and 67% Th, 705 equivalent full power days. Finally, it is possible to conclude that HTRs can reduce time when the waste is considered dangerous. Even if the amount of reduction does not solve the whole problem, it represents an important step in the management of radioactive waste.


Subject(s)
Industrial Waste/prevention & control , Nuclear Reactors , Radiation Monitoring/methods , Radiation Protection/instrumentation , Radioisotopes/analysis , Radioisotopes/chemistry , Refuse Disposal/instrumentation , Computer Simulation , Equipment Failure Analysis/methods , Half-Life , Hot Temperature , Models, Chemical , Models, Statistical , Radiation Dosage , Radiation Protection/methods , Radioisotopes/toxicity , Risk Assessment/methods , Risk Factors
3.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 605-8, 2005.
Article in English | MEDLINE | ID: mdl-16604709

ABSTRACT

Gadolinium has been recently proposed, as neutron capture agent in NCT (Neutron Capture Therapy), due to both the nuclide high neutron capture cross section, and the remarkable selective uptake inside tumour tissue that Gd-loaded compounds, can provide. When a neutron external source is supplied, different Gd nuclear reactions, and the generated Auger electrons in particular, cause a high local energy deposition, which results in a tumour cell inactivation. Preliminary micro- as well as macrodosimetric Monte Carlo computational investigations show that the tumour-to-healthy tissue biological damage ratio is in close relation to the neutron beam energy spectrum. The results points out that the optimum neutron spectrum, to be used for Gd-NCT, seems to lie in the 1 to 10 keV energy range. In order to 'tailor' such spectra, an original, accelerator-driven, neutron source and spectrum shaping assembly for hospital-based Gd-NCT are presented and preliminary results are reported.


Subject(s)
Brain Neoplasms/radiotherapy , Gadolinium/therapeutic use , Models, Biological , Neutron Capture Therapy/methods , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Humans , Radiation Dosage , Radiotherapy Dosage
4.
Appl Radiat Isot ; 61(5): 893-7, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15308164

ABSTRACT

The idea to couple the treatment planning system (TPS) to the information on the real boron distribution in the patient acquired by positron emission tomography (PET) is the main added value of the new methodology set-up at DIMNP (Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione) of University of Pisa, in collaboration with the JRC (Joint Research Centre) at Petten (NL). This methodology has been implemented in a new TPS, called Boron Distribution Treatment Planning System (BDTPS), which takes into account the actual boron distribution in the patient's organ, as opposed to other TPSs used in BNCT that assume an ideal uniform boron distribution. BDTPS is based on the Monte Carlo technique and has been experimentally validated comparing the computed main parameters (thermal neutron flux, boron dose, etc.) to those measured during the irradiation of an ad hoc designed phantom (HEterogeneous BOron phantoM, HEBOM). The results are also in good agreement with those obtained by the standard TPS SERA and by reference calculations carried out using an analytical model with the MCNP code. In this paper, the methodology followed for both the experimental and the computational validation of BDTPS is described.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/instrumentation , Boron , Boron Neutron Capture Therapy/statistics & numerical data , Humans , Monte Carlo Method , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Positron-Emission Tomography , Radiotherapy Planning, Computer-Assisted/statistics & numerical data
5.
Eur J Nucl Med ; 15(11): 683-6, 1989.
Article in English | MEDLINE | ID: mdl-2583192

ABSTRACT

To evaluate scatter fraction and scatter pair spatial distribution, experimental methods are generally used. These methods make use of a line source, placed along the FOV axis, inserted in a cylindrical phantom filled with air or water. The accuracy of these experimental methodologies can be tested by the use of a Monte Carlo method. In fact, the simulation allows the shape of the scatter event projection and the scatter fraction to be defined. An example of this application is the simulation package PETSI (PET SImulation). In this paper the comparison between the predicted scatter fraction and the experimentally evaluated one, obtained using an ECAT III PT 911/02 double ring whole body scanner are presented. PETSI permits additional data to be obtained: a) the true and scatter component of the energy spectrum; b) the spatial distribution, in the FOV plane, of the detected scatter events at different energy thresholds; c) the scatter to total detected events ratio; d) the predicted scatter fraction at both energy thresholds and FOV diameters. This information is very useful for optimizing both energy threshold and FOV size and to improve the accuracy of the currently used methods for the scatter fraction evaluation. Preliminary results of the predicted scatter fraction in a uniform phantom are presented.


Subject(s)
Tomography, Emission-Computed/methods , Models, Structural , Monte Carlo Method , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...