Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Int J Pharm ; 655: 124049, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38537921

ABSTRACT

In in-process quality monitoring for Continuous Manufacturing (CM) and Critical Quality Attributes (CQA) assessment for Real-time Release (RTR) testing, ultrasonic characterization is a critical technology for its direct, non-invasive, rapid, and cost-effective nature. In quality evaluation with ultrasound, relating a pharmaceutical tablet's ultrasonic response to its defect state and quality parameters is essential. However, ultrasonic CQA characterization requires a robust mathematical model, which cannot be obtained with traditional first principles-based modeling approaches. Machine Learning (ML) using experimental data is emerging as a critical analytical tool for overcoming such modeling challenges. In this work, a novel Deep Neural Network-based ML-driven Non-Destructive Evaluation (ML-NDE) modeling framework is developed, and its effectiveness for extracting and predicting three CQAs, namely defect states, compression force levels, and amounts of disintegrant, is demonstrated. Using a robotic tablet handling experimental rig, each attribute's distinct waveform dataset was acquired and utilized for training, validating, and testing the respective ML models. This study details an advanced algorithmic quality assessment framework for pharmaceutical CM in which automated RTR testing is expected to be critical in developing cost-effective in-process real-time monitoring systems. The presented ML-NDE approach has demonstrated its effectiveness through evaluations with separate (unused) test datasets.


Subject(s)
Technology, Pharmaceutical , Ultrasonics , Mechanical Phenomena , Pressure , Tablets
2.
Int J Pharm ; 646: 123477, 2023 Nov 05.
Article in English | MEDLINE | ID: mdl-37797783

ABSTRACT

A compressed pharmaceutical oral solid dosage (OSD) form is a strongly micro-viscoelastic material composite arranged as a network of agglomerated particles due to its constituent powders and their bonding and fractural mechanical properties. An OSD product's Critical Quality Attributes, such as disintegration, drug release (dissolution) profile, and structural strength ("hardness"), are influenced by its micro-scale properties. Ultrasonic evaluation is direct, non-destructive, rapid, and cost-effective. However, for practical process control applications, the simultaneous extraction of the micro-viscoelastic and scattering properties from a tablet's ultrasonic response requires a unique solution to a challenging inverse mathematical wave propagation problem. While the spatial progression of a pulse traveling in a composite medium with known micro-scale properties is a straightforward computational task when its dispersion relation is known, extracting such properties from the experimentally acquired waveforms is often non-trivial. In this work, a novel Machine Learning (ML)-based micro-property extraction technique directly from waveforms, based on Multi-Output Regression models and Neural Networks, is introduced and demonstrated. Synthetic waveforms with a given set of micro-properties of virtual tablets are computationally generated to train, validate, and test the developed ML models for their effectiveness in the inverse problem of recovering specified micro-scale properties. The effectiveness of these ML models is then tested and demonstrated for a set of physical OSD tablets. The micro-viscoelastic and micro-structural properties of physical tablets with known properties have been extracted through experimentally acquired waveforms to exhibit their consistency with the generated ML-based attenuation results.


Subject(s)
Technology, Pharmaceutical , Ultrasonics , Technology, Pharmaceutical/methods , Drug Compounding/methods , Tablets/chemistry , Pressure
3.
Int J Pharm ; 642: 123171, 2023 Jul 25.
Article in English | MEDLINE | ID: mdl-37356509

ABSTRACT

Quality issues related to compressed oral solid dosage (OSD) forms, such as tablets, arise during the design, development, and production stages, despite established processes and robust production tools. One of the primary quality concerns is the disintegration properties and drug release profile of immediate-release OSD products, which depend on their micro-texture and micro-viscoelastic properties at the grain level. These properties are influenced by the composition of the formulation, particularly the disintegrant level in the tablet matrix and the porosity of the matrix. In this study, a novel, rapid, non-destructive ultrasonic characterization technique was proposed to correlate the sensitivity of propagating elastic wave speeds, physical/mechanical properties, and the dispersion profile of the OSD material with the disintegrant level (% w/w) in the formulation and the compression force applied during tableting. The proposed characterization framework involves transmitting pressure (longitudinal) and shear (transverse) waves through the OSDs to calculate the speed of sound, which in turn provides information on the apparent Young's and shear moduli. In addition, the attenuation profile of the propagating wave is obtained through dispersion analysis. To investigate the impact of disintegrants and compression force on ultrasonic wave propagation in OSDs, we incorporated seven levels of a frequently used disintegrant. In each formulation, OSDs are compacted in five compaction forces. The sensitivity of wave speeds, physical/mechanical properties, and attenuation profile was observed with each disintegrant and compression force level. The utilization of ultrasonic techniques may present a viable solution for rapid, non-destructive, non-invasive, and cost-effective testing methods required in continuous manufacturing (CM) and real-time release testing (RTRT), and its practical utility in pharmaceutical manufacturing is also discussed.


Subject(s)
Excipients , Mechanical Phenomena , Tablets , Porosity , Pressure
4.
Int J Pharm ; 635: 122786, 2023 Mar 25.
Article in English | MEDLINE | ID: mdl-36854370

ABSTRACT

In the pharmaceutical manufacturing industry, real-time in situ quality monitoring for detecting defects at an early stage is a desirable ability, especially in high-rate production, to minimize downstream quality-related issues, financial losses, and timeline risks. In this study, we focus on the early detection of crack formation in compressed oral solid dosage (OSD) forms at its onset before complete delamination and/or capping in downstream processing. The detection of internal tablet cracks related to local micro-stress/strain states, internal granularity (texture), and micro-structure failures is rather unlikely by traditional testing methods, such as the USP reference standards for friability, fracturing, or hardness testing. In addition, these tests do not permit the objective and quantitative evaluation of the influence of formulation and process parameters, which are critical for the development of high-quality drug products manufactured at high rates on a large scale. Internal cracks (potentially resulting in 'capping' and/or 'lamination') under high-strain compaction of highly visco-elastic powder materials are a common failure mode. In the current study, two approaches are introduced and utilized for non-destructively detecting and evaluating hidden cracks in pharmaceutical compacts based on (i) varying axial load-displacement measurements and (ii) ultrasonic reflection ray tracing. The reflection ray tracing technique is a non-destructive, inexpensive, rapid, and material-sparing approach, which makes it advantageous for real-time quality monitoring and defect characterization applications. The varying axial load-displacement technique is more suitable for analytical studies, especially in the design and development phases of compressed OSD products. In this study, as a model application, utilizing these two approaches, it is demonstrated how internal and external cracks can be detected, localized, characterized, and analyzed as a function of disintegrant ratio and main compression force. Various uses of these two techniques in practice, such as in Continuous Manufacturing (CM) and Real-Time Release Testing (RTRT), are also discussed.


Subject(s)
Chemistry, Pharmaceutical , Technology, Pharmaceutical , Technology, Pharmaceutical/methods , Chemistry, Pharmaceutical/methods , Tablets/chemistry , Drug Industry/methods , Powders
5.
AAPS PharmSciTech ; 24(1): 22, 2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36536237

ABSTRACT

Due to their constituent powders, the materials of advanced compressed oral solid dosage (OSD) forms are micro-composites and strongly visco-elastic at macro- and micro-length scales. The disintegration, drug release, and mechanical strength of OSD forms depend on its micro-texture (such as porosity) and micro-scale physical/mechanical properties. In the current work, an algorithmic ultrasonic characterization framework for extracting the micro-visco-elastic properties of OSD materials is presented, and its applicability is demonstrated with a model material. The proposed approach is based on the effect of visco-elasticity and granularity on the frequency-dependent attenuation of an ultrasonic wave pulse in a composite (granular) and viscous medium. In modeling the material, a two-parameter Zener model for visco-elasticity and a scattering attenuation mechanism based on Rayleigh scattering for long-wave approximation are employed. A novel linear technique for de-coupling the effects of micro-visco-elasticity and scattering on attenuation and dispersion is developed and demonstrated. The apparent Young's modulus, stress, and strain relaxation time constants of the medium at micro-scale are extracted and reported. Based on this modeling and analysis framework, a set of computational algorithms has been developed and demonstrated with experimental data, and its practical utility in pharmaceutical manufacturing and real-time release testing of tablets is discussed.


Subject(s)
Ultrasonic Waves , Ultrasonics , Elasticity , Elastic Modulus , Tablets
6.
Int J Pharm ; 624: 121993, 2022 Aug 25.
Article in English | MEDLINE | ID: mdl-35811040

ABSTRACT

Despite a well-established process understanding, quality issues for compressed oral solid dosage forms are frequently encountered during various drug product development and production stages. In the current work, a non-destructive contact ultrasonic experimental rig integrated with a collaborative robot arm and an advanced vision system is presented and employed to quantify the effect of the shape of a compressed tablet on its mechanical properties. It is observed that these properties are affected by the tablet geometric shapes and found to be linearly sensitive to the compaction pressures. It is demonstrated that the presented approach significantly improves the repeatability of the experimental waveform acquisition. In addition, with the increased confidence levels in waveform acquisition accuracy and corresponding pressure and shear wave speeds due to improved measurement repeatability, we conclude that pharmaceutical compact materials can indeed have a negative Poisson's ratio, therefore can be auxetic. The presented technique and instrument could find critical applications in continuous tablet manufacturing, and its real-time quality monitoring as measurement repeatability has been significantly improved, minimizing product quality variations.


Subject(s)
Technology, Pharmaceutical , Ultrasonics , Physical Phenomena , Pressure , Tablets , Technology, Pharmaceutical/methods
7.
Int J Pharm ; 623: 121922, 2022 Jul 25.
Article in English | MEDLINE | ID: mdl-35724823

ABSTRACT

In compacted materials, elastic anisotropy coupled with residual stresses could play a determining role in the manifestation of various types of defects such as capping and lamination, as it creates shear planes/bands and temporal relaxation. This internal micro-structure leads to time-delayed flaw initiation/formation, crack tip propagation under residual stresses, and ultimately product quality failures. Thus, their accurate characterization and variations are useful for understanding underlying failure mechanisms and to monitor variations in materials, processes and product quality during production prior to onset of failure. The extraction of tablet anisotropic elasticity properties is a challenging task, especially for commercial tablets with complex shapes, as shape often prevents the use of traditional destructive techniques (e.g., diametric compression testers) to produce accurate measurements. This study introduces and applies an ultrasonic approach to extracting the complete transverse isotropic elastic properties of compressed oral solid dosage forms to a commercial tablet product. A complete set of waveforms and the constitutive matrix for the compacted materials are reported. In addition, a perturbation analysis is carried out to analytically relate propagation speeds in various directions to the elastic coefficients. The proposed characterization approach is non-destructive, rapid, easy, and reliable in evaluating tablet anisotropy.


Subject(s)
Ultrasonics , Anisotropy , Elasticity , Pressure , Tablets/chemistry
8.
Int J Pharm ; 575: 118993, 2020 Feb 15.
Article in English | MEDLINE | ID: mdl-31884061

ABSTRACT

Despite a well-established manufacturing-process understanding, tablet quality issues are frequently encountered during various stages of drug-product development. Compact breaking force (tensile strength), capping and friability are among the commonly observed characteristics that determine the integrity, quality and manufacturability of tablets. In current study, a design space of the compaction pressure, compaction speed and head flat types is introduced for solid dosage compacts prepared from pure silicified microcrystalline cellulose, a popular tableting excipient. In the reported experiments, five types of head flat types at six compaction pressure levels and two compaction speeds were employed and their effects on compact mechanical properties evaluated. The mechanical properties of the tablets were obtained non-destructively. It is demonstrated these properties correlate well with compact porosity and tensile strength, thus their availability is of practical value. The reported mechanical properties are observed to be linearly sensitive to the tableting speed and compaction pressure, and their dependency on the head-flat profile, while clearly visible in the presented waveforms, was found to be nonlinear in the range of the parameter space. In this study, we detail a non-destructive, easy-to-use approach for characterizing the porosity and tensile strength of pharmaceutical tablets.


Subject(s)
Cellulose/chemistry , Tablets/chemistry , Technology, Pharmaceutical/methods , Physical Phenomena , Porosity , Tensile Strength , Ultrasonics
9.
Colloids Surf B Biointerfaces ; 173: 529-538, 2019 Jan 01.
Article in English | MEDLINE | ID: mdl-30342396

ABSTRACT

The accurate determination of the mechanical properties of P-selectin and PSGL-1 is crucial for design and optimization of applications utilizing such bonds, e.g. biosensors and targeted drug delivery systems, as adhesion and mechanical interactions play a critical role in several key functions of biological cells. In current work, the spring constant and rupture force of a single P-selectin PSGL-1 ligand receptor bond and the Young's modulus of a layer made of these ligand receptors are reported. The work-of-adhesion of the P-selectin PSGL-1 interface is also characterized. In the reported experiments, PSGL-1 coated particles are deposited on a P-selectin coated substrate and their transient nanometer scale out-of-plane displacements are acquired employing a laser Doppler vibrometer as they are excited by an ultrasonic field. From the spectral response of a single particle, the resonance frequencies of its vibrational motion are identified, and with help of a particle adhesion model, the average rupture force and stiffness of a single P-selectin PSGL-1 ligand receptor are determined as Frupt = 171 ± 56 pN and kb = 0.56 ± 0.04 mN/m, respectively. Furthermore, the Young's modulus and work-of-adhesion of a layer of P-selectin PSGL-1 ligand receptors are extracted as E = 28.74 ± 3.96 MPa and WA = 70.0 ± 8.0 mJ/m2, respectively. Unlike Atomic Force Microscopy (AFM) and other probe-based techniques, the reported approach eliminates the need for direct contact with the sample, which could compromise the accuracy of the results by imposing unspecified additional contact interactions. Further, the current technique can be employed for measurements under various fluid flow conditions.


Subject(s)
Fluorescein-5-isothiocyanate/chemistry , Immunoglobulin G/chemistry , Membrane Glycoproteins/chemistry , P-Selectin/chemistry , Cell Adhesion , Elastic Modulus , Humans , Materials Testing , Protein Binding , Ultrasonic Waves
10.
Int J Pharm ; 553(1-2): 338-348, 2018 Dec 20.
Article in English | MEDLINE | ID: mdl-30367987

ABSTRACT

Capping is a common mechanical defect in tablet manufacturing, exhibited during or after the compression process. Predicting tablet capping in terms of process variables (e.g. compaction pressure and speed) and formulation properties is essential in pharmaceutical industry. In current work, a non-destructive contact ultrasonic approach for detecting capping risk in the pharmaceutical compacts prepared under various compression forces and speeds is presented. It is shown that the extracted mechanical properties can be used as early indicators for invisible capping (prior to visible damage). Based on the analysis of X-ray cross-section images and a large set of waveform data, it is demonstrated that the mechanical properties and acoustic wave propagation characteristics is significantly modulated by the tablet's internal cracks and capping at higher compaction speeds and pressures. In addition, the experimentally extracted properties were correlated to the directly-measured porosity and tensile strength of compacts of Pearlitol®, Anhydrous Mannitol and LubriTose® Mannitol, produced at two compaction speeds and at three pressure levels. The effect compaction speed and pressure on the porosity and tensile strength of the resulting compacts is quantified, and related to the compact acoustic characteristics and mechanical properties. The detailed experimental approach and reported wave propagation data could find key applications in determining the bounds of manufacturing design spaces in the development phase, predicting capping during (continuous) tablet manufacturing, as well as online monitoring of tablet mechanical integrity and reducing batch-to-batch end-product quality variations.


Subject(s)
Chemistry, Pharmaceutical/methods , Excipients/chemistry , Mannitol/chemistry , Technology, Pharmaceutical/methods , Drug Compounding/methods , Porosity , Pressure , Tablets , Tensile Strength
11.
Colloids Surf B Biointerfaces ; 171: 308-318, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-30053701

ABSTRACT

A non-invasive vibrational spectroscopy technique is introduced and utilized to characterize the average spring constant of a single Superavidin (SAv)-Biotin (Bi).polyethylene glycol (PEG) ligand receptor complex as well as the effective Young's modulus and adhesion of a layer formed by the SAv-Bi.PEG ligand-receptors. In the reported experiments, SAv coated Polystyrene (PS) particles are deposited on a layer of Bi.PEG receptors, bound to a silicon (Si) substrate by silanization. The substrate and the bonded particles are subjected to a pulsed ultrasonic excitation field and their nanometer scale out-of-plane dynamic responses are acquired using a laser vibrometer. The acquired waveforms are processed to obtain the resonance frequencies of the particle motion. Employing a particle adhesion model, the average spring constant of the single ligand-receptor complex and the effective Young's modulus and work-of-adhesion of the SAv-Bi.PEG ligand-receptor layer are extracted from the resonance frequencies. The average spring constant of an individual SAv-Bi.PEG bond is approximated as 0.1-0.4 mN/m. The work-of-adhesion and effective Young's modulus of the SAv-Bi.PEG layer are determined to be 0.54-2.62 J/m2 and 0.15-2.80 MPa, respectively. The compressive Young's modulus of the SAv-Bi.PEG layer is estimated as 31.0-58.0 MPa. The current approach provides a direct non-contact measurement technique for the stiffness of single ligand receptor complexes and the adhesion of their interfaces. SAv-Bi bonds and PEG polymers are among the most widely utilized complexes in the pharmaceutical and biological applications. Understanding the mechanical properties of PEG and SAv-Bi is an important step towards optimization of their utilization in practical applications such as biosensors and targeted drug delivery.


Subject(s)
Avidin/chemistry , Biotin/chemistry , Polyethylene Glycols/chemistry , Elastic Modulus , Ligands , Particle Size , Silicon/chemistry , Surface Properties
12.
Int J Pharm ; 542(1-2): 153-163, 2018 May 05.
Article in English | MEDLINE | ID: mdl-29535040

ABSTRACT

Currently, the compressed tablet and its oral administration is the most popular drug delivery modality in medicine. The accurate porosity and tensile strength characterization of a tablet design is vital for predicting its performance such as disintegration, dissolution, and drug-release efficiency upon administration as well as ensuring its mechanical integrity. In current work, a non-destructive contact ultrasonic approach and an associated testing procedure are presented and employed to quantify and relate the acoustically extracted mechanical properties of pharmaceutical compacts to direct porosity and tensile strength measurements. Based on a comprehensive set of experimental data, it is demonstrated how strongly the acoustic wave propagation is modulated and correlated to the tablet porosity and tensile strength of a compact made using spray-dried lactose and microcrystalline cellulose with varying mixture ratios. The effect of mixing ratio on the porosity and tensile strength on the resulting compacts is quantified and, with the acoustic experimental data, mixing ratio is related to the compact ultrasonic characteristics. The ultrasonic techniques provide a rapid, non-destructive means for evaluating compacts in formulation development and manufacturing. The presented approach and data could find critical applications in continuous tablet manufacturing, its real-time quality monitoring, as well as minimizing batch-to-batch quality variations.


Subject(s)
Tablets/chemistry , Technology, Pharmaceutical/methods , Ultrasonic Waves , Cellulose/chemistry , Drug Liberation , Lactose/chemistry , Porosity , Quality Control , Tensile Strength
13.
Int J Pharm ; 454(1): 333-43, 2013 Sep 15.
Article in English | MEDLINE | ID: mdl-23820132

ABSTRACT

The mechanical properties of a solid dosage, defined by its granular micro-structure and geometry, play a key role in its dissolution profile and performance. An ultrasonic method for extracting the viscoelastic material properties and granular structure of drug tablet compacts is introduced and its utility is demonstrated for tablet compacts made of microcrystalline cellulose (MCC), lactose monohydrate, and sodium starch glycolate as well as magnesium stearate as lubricant. The approach is based on the effect of viscoelasticity and internal micro-structures on the frequency-dependent attenuation of an ultrasonic wave propagating in a granular medium. The models for viscoelastic (a two-parameter Zener model) and scattering attenuation (Rayleigh model) mechanisms are employed. The material parameters including viscoelastic and scattering parameters (average Young's modulus, stress and strain relaxation time constants, and the Rayleigh scattering material parameter) and grain size distribution with a known distribution profile are extracted by an optimization algorithm based on the least square method. The results also indicate good agreement between experimentally and computationally determined phase and group velocities in compacted samples. It is found that the effects of both attenuation mechanisms are present and the extracted grain size distribution parameters are in good agreement with the optically determined values.


Subject(s)
Excipients/chemistry , Technology, Pharmaceutical/methods , Ultrasonics , Algorithms , Cellulose/chemistry , Chemistry, Pharmaceutical , Elastic Modulus , Elasticity , Lactose/chemistry , Least-Squares Analysis , Lubricants/chemistry , Models, Chemical , Molecular Structure , Particle Size , Scattering, Radiation , Starch/analogs & derivatives , Starch/chemistry , Stearic Acids/chemistry , Stress, Mechanical , Tablets , Technology, Pharmaceutical/instrumentation , Transducers , Ultrasonics/instrumentation , Viscosity
14.
Int J Pharm ; 442(1-2): 20-6, 2013 Feb 14.
Article in English | MEDLINE | ID: mdl-22989980

ABSTRACT

The mechanical properties of a drug tablet can affect its performance (e.g., dissolution profile and its physical robustness. An ultrasonic system for real-time in-die tablet mechanical property monitoring during compaction has been demonstrated. The reported set-up is a proof of concept compaction monitoring system which includes an ultrasonic transducer mounted inside the upper punch of the compaction apparatus. This upper punch is utilized to acquire ultrasonic pressure wave phase velocity waveforms and extract the time-of-flight of pressure waves travelling within the compact at a number of compaction force levels during compaction. The reflection coefficients for the waves reflecting from punch tip-powder bed interface are extracted from the acquired waveforms. The reflection coefficient decreases with an increase in compaction force, indicating solidification. The data acquisition methods give an average apparent Young's moduli in the range of 8-20 GPa extracted during the compaction and release/decompression phases in real-time. A monitoring system employing such methods is capable of determining material properties and the integrity of the tablet during compaction. As compared to the millisecond time-scale dwell time of a typical commercial compaction press, the micro-second pulse duration and ToF of an acoustic pulse are sufficiently fast for real-time monitoring.


Subject(s)
Acoustics , Computer Systems , Drug Compounding/instrumentation , Tablets/chemistry , Cellulose/chemistry , Elastic Modulus , Excipients/chemistry , Lactose/chemistry , Quality Control , Technology, Pharmaceutical/instrumentation
16.
Int J Pharm ; 419(1-2): 137-46, 2011 Oct 31.
Article in English | MEDLINE | ID: mdl-21821106

ABSTRACT

An ultrasonic non-destructive technique for the microstructure length-scale characterization of solid dosage pharmaceutical tablets is presented. The technique is based on the relationship between the attenuation of longitudinal ultrasonic elastic waves and the size of micro-structural features in the tablet material. In the reported experiments, the ultrasonic attenuation in microcrystalline cellulose (MCC)-lactose monohydrate (LMH) blended pharmaceutical compacts is measured by means of two pitch-catch experiments. The frequency dependent attenuation coefficient for the MCC-LMH compacts is then related to the mean grain diameter for each compact. For verification purposes, the mean grain diameter of the compacts was also established using micro-scale X-ray computerized tomography (MicroXCT). The mean grain diameters established by both routines agree well, and support the efficacy of the ultrasonic attenuation technique. The microstructure of a pharmaceutical compact (i.e., grain sizes and micro-feature size distribution) has been shown to have a profound effect on its mechanical properties, namely hardness, porosity, and mass density distribution, and in turn, can critically impact the dissolution profile and structural integrity of a compact. The ultrasonic technique presented provides a non-destructive and rapid method for determining the mean grain diameter size for powder compacts, thus providing a more timely and cost-effective method, compared to traditional techniques, of characterizing a compact's internal microstructure.


Subject(s)
Cellulose/chemistry , Lactose/chemistry , Ultrasonics , X-Ray Microtomography/methods , Excipients/chemistry , Hardness , Particle Size , Porosity , Powders , Solubility , Tablets
17.
Int J Pharm ; 414(1-2): 171-8, 2011 Jul 29.
Article in English | MEDLINE | ID: mdl-21605647

ABSTRACT

The practicability of a pulse-echo ultrasonic approach developed for the real-time quality monitoring of dry-coated tablets in the tablet press during compaction is evaluated. The punch-tablet interface (i.e., steel-tablet) is the boundary condition that dictates the viability of acoustic in-die compaction monitoring. The current study utilizes compacted tablets with a simulated punch-tablet interface to achieve the required waveform detectability levels needed for in-die compaction monitoring. The geometric and mechanical properties of a dry-coated tablet are crucial to its structural functions and therapeutic effectiveness, therefore they are monitored especially when the control of dissolution rates of their active ingredients are critically important. Acquired pulse-echo ultrasonic waveforms in the tablet could provide the time-of-flight information needed to determine the thickness, elasticity and/or integrity of the relevant layer, and bonding quality between layers depending on the given parameters. Since the amplitudes of the reflected waves are extremely low due to the high acoustic impedance mismatches of tablet materials and die/punch materials, signal processing techniques are required to extract the wave arrival times. In current study, it is demonstrated that the reflection of an ultrasonic pulse generated by a transducer embedded in a die or a punch from the coat-core interface can be acquired by the same transducer.


Subject(s)
Computer Systems , Tablets/analysis , Compressive Strength , Drug Compounding/methods , Excipients/chemistry , Software , Tablets/chemistry , Time Factors , Ultrasonography/methods
18.
Int J Pharm ; 392(1-2): 148-55, 2010 Jun 15.
Article in English | MEDLINE | ID: mdl-20363299

ABSTRACT

A dry-coated tablet is a solid dosage form with a controlled drug-release system, which consists of a core and an outer layer. The accuracy of its geometric (e.g. the outer layer wall and core thicknesses) and mechanical properties (e.g. Young's moduli and mass densities of associated materials) could be crucial to its therapeutic and structural functions. The objective of current study is to develop a non-destructive technique for determining the geometric and mechanical properties of dry-coated tablets. Two contact ultrasonic techniques (i.e. pitch-catch and pulse-echo measurement modes) are employed and the properties of all the structural components of a set of experimental tablets are measured and reported. The thicknesses of the outer layers of the sample tablets are used to obtain the eccentricity of the core tablets. The two approaches are compared for their effectiveness in obtaining these properties of the sample dry-coated tablets. The thicknesses of the outer layers obtained with the proposed approach and with the direct (destructive) measurements are also compared. A good agreement is found; there is an approximately 2% difference. The eccentricity and concentricity of a set of tablets are determined and it is concluded that the observed consistent anomaly in eccentricity can be attributed to the same root cause and its correction can be achieved by control input based on monitoring data. Potential of the approach for in-die real-time monitoring of compaction presses and its PAT (Process Analytical Technology) applications for the pharmaceutical manufacturing are also discussed.


Subject(s)
Mechanical Phenomena , Tablets, Enteric-Coated/chemistry , Technology, Pharmaceutical/methods , Ultrasonics , Drug Compounding , Drug Stability , Surface Properties , Technology, Pharmaceutical/instrumentation
19.
AAPS PharmSciTech ; 11(1): 90-102, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20063078

ABSTRACT

A noncontact/nondestructive air-coupled acoustic technique to be potentially used in mechanical property determination of bilayer tablets is presented. In the reported experiments, a bilayer tablet is vibrated via an acoustic field of an air-coupled transducer in a frequency range sufficiently high to excite several vibrational modes (harmonics) of the tablet. The tablet vibrational transient responses at a number of measurement points on the tablet are acquired by a laser vibrometer in a noncontact manner. An iterative computational procedure based on the finite element method is utilized to extract the Young's modulus, the Poisson's ratio, and the mass density values of each layer material of a bilayer tablet from a subset of the measured resonance frequencies. For verification purposes, a contact ultrasonic technique based on the time-of-flight data of the longitudinal (pressure) and transverse (shear) acoustic waves in each layer of a bilayer tablet is also utilized. The extracted mechanical properties from the air-coupled acoustic data agree well with those determined from the contact ultrasonic measurements. The mechanical properties of solid oral dosage forms have been shown to impact its mechanical integrity, disintegration profile and the release rate of the drug in the digestive tract, thus potentially affecting its therapeutic response. The presented nondestructive technique provides greater insight into the mechanical properties of the bilayer tablets and has the potential to identify quality and performance problems related to the mechanical properties of the bilayer tablets early on the production process and, consequently, reduce associated cost and material waste.


Subject(s)
Acoustics , Air , Pharmaceutical Preparations/chemistry , Tablets/chemistry , Ultrasonics , Dosage Forms , Excipients , Lasers , Pressure , Vibration
20.
Int J Pharm ; 370(1-2): 17-25, 2009 Mar 31.
Article in English | MEDLINE | ID: mdl-19059326

ABSTRACT

Many modern tablet presses have system controls that monitor the force exerted to compress the solid oral dosage forms; however this data provides only limited information about the mechanical state of the tablet due to various process and materials uncertainties. A contact pulse/echo ultrasonic scheme is presented for the determination of the local Young's moduli of the coat and the core materials of enteric-coated and monolayer coated tablets. The Young's modulus of a material compacted into solid dosage can be related to its mechanical hardness and, consequently, its dissolution rate. In the current approach, short ultrasonic pulses are generated by the active element of a delay line transducer and are launched into the tablet. The waveforms reflected from the tablet coat-core interface are captured by the same transducer and are processed for determining the reflection and transmission coefficients of the interface from partially overlapping echoes. The Young's moduli of the coat and the core materials are then extracted from these coefficients. The results are compared to those obtained by an air-coupled acoustic excitation study, and good agreement is found. The described measurement technique provides greater insight into the local physical properties of the solid oral dosage form and, as a result, has the potential to provide better hardness-related performance predictability of compacts.


Subject(s)
Drug Compounding/methods , Elastic Modulus , Pharmaceutical Preparations/chemistry , Tablets/chemistry , Technology, Pharmaceutical/methods , Ultrasonics , Algorithms , Chemistry, Pharmaceutical , Compressive Strength , Drug Storage , Hardness , Materials Testing , Quality Control , Solubility , Stress, Mechanical , Surface Properties , Tablets/analysis , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...