1.
Bioengineering (Basel) ; 11(4)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38671752

ABSTRACT

In recent years, indirect digital radiography detectors have been actively studied to improve radiographic image performance with low radiation exposure. This study aimed to achieve low-dose radiation imaging with a thick scintillation detector while simultaneously obtaining the resolution of a thin scintillation detector. The proposed method was used to predict the optimal point spread function (PSF) between thin and thick scintillation detectors by considering image quality assessment (IQA). The process of identifying the optimal PSF was performed on each sub-band in the wavelet domain to improve restoration accuracy. In the experiments, the edge preservation index (EPI) values of the non-blind deblurred image with a blurring sigma of σ = 5.13 pixels and the image obtained with optimal parameters from the thick scintillator using the proposed method were approximately 0.62 and 0.76, respectively. The coefficient of variation (COV) values for the two images were approximately 1.02 and 0.63, respectively. The proposed method was validated through simulations and experimental results, and its viability is expected to be verified on various radiological imaging systems.

2.
Med Phys ; 51(2): 1509-1530, 2024 Feb.
Article in English | MEDLINE | ID: mdl-36846955

ABSTRACT

BACKGROUND: Dual-energy (DE) chest radiography (CXR) enables the selective imaging of two relevant materials, namely, soft tissue and bone structures, to better characterize various chest pathologies (i.e., lung nodule, bony lesions, etc.) and potentially improve CXR-based diagnosis. Recently, deep-learning-based image synthesis techniques have attracted considerable attention as alternatives to existing DE methods (i.e., dual-exposure-based and sandwich-detector-based methods) because software-based bone-only and bone-suppression images in CXR could be useful. PURPOSE: The objective of this study was to develop a new framework for DE-like CXR image synthesis from single-energy computed tomography (CT) based on a cycle-consistent generative adversarial network. METHODS: The core techniques of the proposed framework are divided into three categories: (1) data configuration from the generation of pseudo CXR from single energy CT, (2) learning of the developed network architecture using pseudo CXR and pseudo-DE imaging using a single-energy CT, and (3) inference of the trained network on real single-energy CXR. We performed a visual inspection and comparative evaluation using various metrics and introduced a figure of image quality (FIQ) to consider the effects of our framework on the spatial resolution and noise in terms of a single index through various test cases. RESULTS: Our results indicate that the proposed framework is effective and exhibits potential synthetic imaging ability for two relevant materials: soft tissue and bone structures. Its effectiveness was validated, and its ability to overcome the limitations associated with DE imaging techniques (e.g., increase in exposure dose owing to the requirement of two acquisitions, and emphasis on noise characteristics) via an artificial intelligence technique was presented. CONCLUSIONS: The developed framework addresses X-ray dose issues in the field of radiation imaging and enables pseudo-DE imaging with single exposure.


Subject(s)
Artificial Intelligence , Image Processing, Computer-Assisted , Image Processing, Computer-Assisted/methods , Radiography , Tomography, X-Ray Computed/methods , Thorax/diagnostic imaging
3.
Sensors (Basel) ; 23(24)2023 Dec 13.
Article in English | MEDLINE | ID: mdl-38139649

ABSTRACT

The resulting image obtained from an X-ray imaging system depends significantly on the characteristics of the detector. In particular, when an X-ray image is acquired by thinning the detector, a relatively large amount of noise inevitably occurs. In addition, when a thick detector is used to reduce noise in X-ray images, blurring increases and the ability to distinguish target areas deteriorates. In this study, we aimed to derive the optimal X-ray image quality by deriving the optimal noise reduction parameters based on the non-local means (NLM) algorithm. The detectors used were of two thicknesses (96 and 140 µm), and images were acquired based on the IEC 62220-1-1:2015 RQA-5 protocol. The optimal parameters were derived by calculating the edge preservation index and signal-to-noise ratio according to the sigma value of the NLM algorithm. As a result, a sigma value of the optimized NLM algorithm (0.01) was derived, and this algorithm was applied to a relatively thin X-ray detector system to obtain appropriate noise level and spatial resolution data. The no-reference-based blind/referenceless image spatial quality evaluator value, which analyzes the overall image quality, was best when using the proposed method. In conclusion, we propose an optimized NLM algorithm based on a new method that can overcome the noise amplification problem in thin X-ray detector systems and is expected to be applied in various photon imaging fields in the future.

4.
Sensors (Basel) ; 23(19)2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37837015

ABSTRACT

An indirect conversion X-ray detector uses a scintillator that utilizes the proportionality of the intensity of incident radiation to the amount of visible light emitted. A thicker scintillator reduces the patient's dose while decreasing the sharpness. A thin scintillator has an advantage in terms of sharpness; however, its noise component increases. Thus, the proposed method converts the spatial resolution of radiographic images acquired from a normal-thickness scintillation detector into a thin-thickness scintillation detector. Note that noise amplification and artifacts were minimized as much as possible after non-blind deconvolution. To accomplish this, the proposed algorithm estimates the optimal point-spread function (PSF) when the structural similarity index (SSIM) and feature similarity index (FSIM) are the most similar between thick and thin scintillator images. Simulation and experimental results demonstrate the viability of the proposed method. Moreover, the deconvolution images obtained using the proposed scheme show an effective image restoration method in terms of the human visible system compared to that of the traditional PSF measurement technique. Consequently, the proposed method is useful for restoring degraded images using the adaptive PSF while preventing noise amplification and artifacts and is effective in improving the image quality in the present X-ray imaging system.

5.
Sensors (Basel) ; 20(22)2020 Nov 10.
Article in English | MEDLINE | ID: mdl-33182640

ABSTRACT

In this study, the effect of filter schemes on several low-contrast materials was compared using standard and ultra-high-resolution (UHR) cone-beam computed tomography (CBCT) imaging. The performance of the UHR-CBCT was quantified by measuring the modulation transfer function (MTF) and the noise power spectrum (NPS). The MTF was measured at the radial location around the cylindrical phantom, whereas the NPS was measured in the eight different homogeneous regions of interest. Six different filter schemes were designed and implemented in the CT sinogram from each imaging configuration. The experimental results indicated that the filter with smaller smoothing window preserved the MTF up to the highest spatial frequency, but larger NPS. In addition, the UHR imaging protocol provided 1.77 times better spatial resolution than the standard acquisition by comparing the specific spatial frequency (f50) under the same conditions. The f50s with the flat-top window in UHR mode was 1.86, 0.94, 2.52, 2.05, and 1.86 lp/mm for Polyethylene (Material 1, M1), Polystyrene (M2), Nylon (M3), Acrylic (M4), and Polycarbonate (M5), respectively. The smoothing window in the UHR protocol showed a clearer performance in the MTF according to the low-contrast objects, showing agreement with the relative contrast of materials in order of M3, M4, M1, M5, and M2. In conclusion, although the UHR-CBCT showed the disadvantages of acquisition time and radiation dose, it could provide greater spatial resolution with smaller noise property compared to standard imaging; moreover, the optimal window function should be considered in advance for the best UHR performance.

6.
J Radiol Prot ; 40(4)2020 Nov 11.
Article in English | MEDLINE | ID: mdl-33027779

ABSTRACT

This study investigated the feasibility of dosimetric measurements using Al2O3:C optically stimulated luminescence (OSL) dosimeters during fluoroscopy-guided procedures. The linearity and energy dependence of Al2O3:C OSL dosimeters were evaluated, and the air kerma rate at the operator's position was measured. The response of Al2O3:C OSL dosimeters to short, repetitive irradiations was compared to that of long uninterrupted irradiation. The change in response of the Al2O3:C OSL dosimeter under automatic exposure rate control (AERC) was evaluated with the use of various thicknesses of polymethyl-methacrylate (PMMA) plates (15-30 cm). The Al2O3:C OSL dosimeters could detect 5µGy and showed good linearity in doses of ≥10µGy (R2: 0.997-0.999,p< 0.001). The relative response of the Al2O3:C OSL dosimeter normalised to that of 36.8 keV was 0.828-1.101 at the energies investigated (30.6-46.0 keV). The air kerma rate at the operator's position was estimated to be 2.61-7.17µGy min-1depending on the heights representing different body parts. Repetitive short irradiations had no significant impact on the relative response of the Al2O3:C OSL dosimeters (p> 0.05). Despite a high energy dependence on the low energy beam used in fluoroscopy, the change in relative response of the Al2O3:C OSL dosimeter under AERC was within 5.7% depending on the thickness of the PMMA plates. Dosimetric measurement using Al2O3:C OSL dosimeters for patients and operators is feasible. However, one should be cautious about high standard deviations when measuring small doses of ≤20µGy using Al2O3:C OSL dosimeters. It is essential to perform intensive bleaching before measuring very small doses to minimise pre-irradiation counts.


Subject(s)
Aluminum Oxide , Radiation Dosimeters , Feasibility Studies , Fluoroscopy , Humans , Radiation Dosage