Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Clin Exp Immunol ; 181(2): 338-42, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25766782

ABSTRACT

The aim of this study was to investigate CXCL-1 chemokine levels in the vitreous during rhegmatogenous retinal detachment (RRD) with and without proliferative vitreoretinopathy (PVR) and identify possible correlations with clinical parameters (extent and duration or RRD and PVR grade). Vitreous samples from patients with primary RRD with or without PVR were collected and assayed using a double antibody enzyme-linked immunosorbent assay (ELISA). Eleven vitreous samples from organ donors were employed as a control group. CXCL-1 levels were measured in 35 vitreous samples from 35 RRD patients. Mean CXCL-1 levels (64·82 ± 6·47 pg/ml) were significantly higher (P = 0·048) compared to controls. There was a significant positive correlation between CXCL-1 levels and the extent of the detachment (r = 0·794, P = 0·006). Peak CXCL-1 levels coincided with 3+ quadrant RRD, an interim of 29-60 days' duration and PVR grade B. Increased CXCL-1 levels may be indicative of mild inflammation in the detached retina and the adjacent vitreous. The results of the present study may provide novel insight into the complex interactions taking place during the early and late stages of RRD complicated by PVR.


Subject(s)
Eye Diseases, Hereditary/immunology , Retina/immunology , Retinal Detachment/immunology , Vitreoretinopathy, Proliferative/immunology , Adult , Aged , Aged, 80 and over , Biomarkers/metabolism , Case-Control Studies , Chemokine CXCL1/genetics , Chemokine CXCL1/immunology , Eye Diseases, Hereditary/complications , Eye Diseases, Hereditary/diagnosis , Eye Diseases, Hereditary/pathology , Female , Gene Expression , Humans , Male , Middle Aged , Retina/pathology , Retinal Detachment/complications , Retinal Detachment/diagnosis , Retinal Detachment/pathology , Severity of Illness Index , Subretinal Fluid/chemistry , Subretinal Fluid/immunology , Vitreoretinopathy, Proliferative/complications , Vitreoretinopathy, Proliferative/diagnosis , Vitreoretinopathy, Proliferative/pathology , Vitreous Body/chemistry , Vitreous Body/immunology
3.
Curr Eye Res ; 34(6): 447-53, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19899979

ABSTRACT

PURPOSE: To determine repeatability and reproducibility of A-scan biometry quantitative findings in order to uniformly evaluate lenticular cataract changes. MATERIALS AND METHODS: Seventeen eyes from seventeen cataract patients were examined by three (trainee ophthalmologists). Results (ratio of mean internal lens spikes height/lens anterior surface spike height) were compared using coefficient of variation (CV), repeatability coefficient (CR), and intraclass correlation coefficients (ICC). RESULTS: Intra-observer consistency was CV = 0.36, CR = 0.49, and ICC = 0.778 for the first operator; CV = 0.33, CR = 0.52, and ICC = 0.642 for the second operator; and CV = 0.32, CR = 0.53, and ICC = 0.567 for the third operator. Concerning inter-observer agreement: CV (in 6 of 7 eyes) was > 8%, CR was > 0.21, and intraclass correlation coefficient for all eyes was < 0.81. CONCLUSIONS: Regarding repeatability and reproducibility, although there is a tendency for statistical significance, variability of the results does not allow the use of the method as a complementary clinical tool for comparing results. Standardization of this procedure, in order to achieve higher test reliability, might be the aim of relevant future studies, although there are a number of points that have to be addressed.


Subject(s)
Biometry , Cataract/diagnostic imaging , Diagnostic Techniques, Ophthalmological , Aged , Aged, 80 and over , Eye/diagnostic imaging , Female , Humans , Male , Observer Variation , Prospective Studies , Reproducibility of Results , Ultrasonography
4.
Klin Monbl Augenheilkd ; 221(2): 122-4, 2004 Feb.
Article in German | MEDLINE | ID: mdl-14986211

ABSTRACT

BACKGROUND: In the literature there have often been reports about deposits (hydroxyapatite) in hydrophilic or hydrophobic intraocular lenses (IOLs). We report, for the first time, about deposits on a silicone IOL of the second generation. MATERIALS AND METHODS: A silicone IOL (Allergan, type SI-40) which was extracted due to gradual visual loss, has been examined. RESULTS: The examination with the scanning electron microscope (SEM) showed crystalline precipitations in the anterior surface of the IOL while the X-ray analysis showed the existence of calcium and carbon, whereas no phosphorus was found. CONCLUSIONS: It could be hypothesised that metabolic disorders in aqueous humor (i. e., in patients with diabetes mellitus), the quality of the production of the lens, and not the IOL material, are the main cause for deposits in the IOL surface.


Subject(s)
Equipment Failure Analysis , Lenses, Intraocular , Silicones , Aged , Calcium/analysis , Carbon/analysis , Crystallization , Device Removal , Diabetes Complications , Durapatite/analysis , Electron Probe Microanalysis , Humans , Hydrogel, Polyethylene Glycol Dimethacrylate , Male , Microscopy, Electron , Phosphorus/analysis , Postoperative Complications/etiology , Postoperative Complications/surgery , Prosthesis Design , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...