Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Cancers (Basel) ; 14(22)2022 Nov 10.
Article in English | MEDLINE | ID: mdl-36428614

ABSTRACT

Although multimodal ultrasound approaches have been suggested to potentially improve the diagnosis of thyroid cancer; the diagnostic utility of the combination of SWE and malignancy-risk stratification systems remains vague due to the lack of standardized criteria. The purpose of the study was to assess the diagnostic value of the combination of grey scale ultrasound assessment using EU TIRADS and shear wave elastography. 121 patients (126 nodules−81 benign; 45 malignant) underwent grey scale ultrasound and SWE imaging of nodules between 0.5 cm and 5 cm prior to biopsy and/or surgery. Nodules were analyzed based on size stratifications: <1 cm (n = 43); 1−2 cm (n = 52) and >2 cm (n = 31) and equivocal cytology status (n = 52), and diagnostic performance assessments were conducted. The combination of EU TIRADS with SWE using the SD parameter; maintained a high sensitivity and significantly improved the specificity of sole EU TIRADS for nodules 1−2 cm (SEN: 72.2% vs. 88.9%, p > 0.05; SPEC: 76.5% vs. 55.9%, p < 0.01) and >2 cm (SEN: 71.4% vs. 85.7%, p > 0.05; SPEC: 95.8% vs. 62.5%, p < 0.01). For cytologically-equivocal nodules; the combination with the SWE minimum parameter resulted in a significant reduction in sensitivity with increased specificity (SEN: 60% vs. 80%; SPEC: 83.4% vs. 37.8%; all p < 0.05). SWE in combination with EU TIRADS is diagnostically efficient in discriminating nodules > 1 cm but is not ideal for discriminating cytologically-equivocal nodules.

2.
Children (Basel) ; 9(11)2022 Oct 31.
Article in English | MEDLINE | ID: mdl-36360404

ABSTRACT

The early diagnosis of biliary atresia (BA) in cholestatic infants is critical to the success of the treatment. Intraoperative cholangiography (IOC), an invasive imaging technique, is the current strategy for the diagnosis of BA. Ultrasonography has advanced over recent years and emerging techniques such as shear wave elastography (SWE) have the potential to improve BA diagnosis. This review sought to evaluate the diagnostic efficacy of advanced ultrasonography techniques in the diagnosis of BA. Six databases (CINAHL, Medline, PubMed, Google Scholar, Web of Science (core collection), and Embase) were searched for studies assessing the diagnostic performance of advanced ultrasonography techniques in differentiating BA from non-BA causes of infantile cholestasis. The meta-analysis was performed using Meta-DiSc 1.4 and Comprehensive Meta-analysis v3 software. Quality Assessment of Diagnostic Accuracy Studies tool version 2 (QUADAS-2) assessed the risk of bias. Fifteen studies consisting of 2185 patients (BA = 1105; non-BA = 1080) met the inclusion criteria. SWE was the only advanced ultrasonography technique reported and had a good pooled diagnostic performance (sensitivity = 83%; specificity = 77%; AUC = 0.896). Liver stiffness indicators were significantly higher in BA compared to non-BA patients (p < 0.000). SWE could be a useful tool in differentiating BA from non-BA causes of infantile cholestasis. Future studies to assess the utility of other advanced ultrasonography techniques are recommended.

3.
Biomedicines ; 10(7)2022 Jun 29.
Article in English | MEDLINE | ID: mdl-35884858

ABSTRACT

This study investigated the diagnostic value of the Angio Planewave Ultrasensitive (AngioPLUS) Doppler ultrasound in improving the efficacy of grey scale ultrasound in thyroid nodule diagnosis. The EU TIRADS was used for the grey scale ultrasound assessment of 94 thyroid nodules. conventional Doppler and AngioPLUS Doppler ultrasound images were evaluated using qualitative vascularity grading, where predominant central vascularity indicated malignancy-suspicion, and quantitative regional vascularity assessment, where predominant peripheral vascularity using a ratio vascularity index (RVI) of > 1 indicated benign disease. Diagnostic performance outcomes of sole and combination approaches were calculated based on final pathologic results. Using sole EU TIRADS and AngioPLUS + power Doppler imaging (APDI) based on qualitative vascularity and RVI, the results were a sensitivity of 83.3% vs. 83.3 vs. 66.7% and a specificity of 50% vs. 81.3% vs. 73.4, respectively. EU TIRADS combined with APDI significantly improved the specificity using both qualitative vascularity and RVI assessment approaches (84.4% and 81%, respectively, p < 0.05); and slightly reduced the sensitivity (76.7% and 58.1%). For cytologically-equivocal thyroid nodules, the combination approach using qualitative vascularity assessment outperformed the EU TIRADS (sensitivity: both were 88.9%; specificity: 77.4% vs. 38.7%, p < 0.05; and AUROC: 0.83 vs. 0.62, p < 0.05). APDI combined with EU TIRADS is diagnostically efficient in stratifying thyroid nodules, particularly cytologically-equivocal nodules.

4.
Life (Basel) ; 11(11)2021 Oct 27.
Article in English | MEDLINE | ID: mdl-34833024

ABSTRACT

The value of computer-aided diagnosis (CAD) and computer-assisted techniques equipped with different TIRADS remains ambiguous. Parallel diagnosis performances of computer-assisted subjective assessments and CAD were compared based on AACE, ATA, EU, and KSThR TIRADS. CAD software computed the diagnosis of 162 thyroid nodule sonograms. Two raters (R1 and R2) independently rated the sonographic features of the nodules using an online risk calculator while blinded to pathology results. Diagnostic efficiency measures were calculated based on the final pathology results. R1 had higher diagnostic performance outcomes than CAD with similarities between KSThR (SEN: 90.3% vs. 83.9%, p = 0.57; SPEC: 46% vs. 51%, p = 0.21; AUROC: 0.76 vs. 0.67, p = 0.02), and EU (SEN: 85.5% vs. 79%, p = 0.82; SPEC: 62% vs. 55%, p = 0.27; AUROC: 0.74 vs. 0.67, p = 0.06). Similarly, R2 had higher AUROC and specificity but lower sensitivity than CAD (KSThR-AUROC: 0.74 vs. 0.67, p = 0.13; SPEC: 61% vs. 46%, p = 0.02 and SEN: 75.8% vs. 83.9%, p = 0.31, and EU-AUROC: 0.69 vs. 0.67, p = 0.57, SPEC: 64% vs. 55%, p = 0.19, and SEN: 71% vs. 79%, p = 0.51, respectively). CAD had higher sensitivity but lower specificity than both R1 and R2 with AACE for 114 specified nodules (SEN: 92.5% vs. 88.7%, p = 0.50; 92.5% vs. 79.3%, p = 0.02, and SPEC: 26.2% vs. 54.1%, p = 0.001; 26.2% vs. 62.3%, p < 0.001, respectively). All diagnostic performance outcomes were comparable for ATA with 96 specified nodules. Computer-assisted subjective interpretation using KSThR is more ideal for ruling out papillary thyroid carcinomas than CAD. Future larger multi-center and multi-rater prospective studies with a diverse representation of thyroid cancers are necessary to validate these findings.

5.
PLoS One ; 16(1): e0245617, 2021.
Article in English | MEDLINE | ID: mdl-33449958

ABSTRACT

BACKGROUND: Thyroid cancer diagnosis has evolved to include computer-aided diagnosis (CAD) approaches to overcome the limitations of human ultrasound feature assessment. This study aimed to evaluate the diagnostic performance of a CAD system in thyroid nodule differentiation using varied settings. METHODS: Ultrasound images of 205 thyroid nodules from 198 patients were analysed in this retrospective study. AmCAD-UT software was used at default settings and 3 adjusted settings to diagnose the nodules. Six risk-stratification systems in the software were used to classify the thyroid nodules: The American Thyroid Association (ATA), American College of Radiology Thyroid Imaging, Reporting, and Data System (ACR-TIRADS), British Thyroid Association (BTA), European Union (EU-TIRADS), Kwak (2011) and the Korean Society of Thyroid Radiology (KSThR). The diagnostic performance of CAD was determined relative to the histopathology and/or cytology diagnosis of each nodule. RESULTS: At the default setting, EU-TIRADS yielded the highest sensitivity, 82.6% and lowest specificity, 42.1% while the ATA-TIRADS yielded the highest specificity, 66.4%. Kwak had the highest AUROC (0.74) which was comparable to that of ACR, ATA, and KSThR TIRADS (0.72, 0.73, and 0.70 respectively). At a hyperechoic foci setting of 3.5 with other settings at median values; ATA had the best-balanced sensitivity, specificity and good AUROC (70.4%; 67.3% and 0.71 respectively). CONCLUSION: The default setting achieved the best diagnostic performance with all TIRADS and was best for maximizing the sensitivity of EU-TIRADS. Adjusting the settings by only reducing the sensitivity to echogenic foci may be most helpful for improving specificity with minimal change in sensitivity.


Subject(s)
Diagnosis, Computer-Assisted , Image Processing, Computer-Assisted , Software , Thyroid Nodule/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Ultrasonography
6.
Cancers (Basel) ; 11(11)2019 Nov 08.
Article in English | MEDLINE | ID: mdl-31717365

ABSTRACT

Computer-aided diagnosis (CAD) techniques have emerged to complement qualitative assessment in the diagnosis of benign and malignant thyroid nodules. The aim of this review was to summarize the current evidence on the diagnostic performance of various ultrasound CAD in characterizing thyroid nodules. PUBMED, EMBASE and Cochrane databases were searched for studies published until August 2019. The Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Review 2 (QUADAS-2) tool was used to assess the methodological quality of the studies. Reported diagnostic performance data were analyzed and discussed. Fourteen studies with 2232 patients and 2675 thyroid nodules met the inclusion criteria. The study quality based on QUADAS-2 assessment was moderate. At best performance, grey scale CAD had a sensitivity of 96.7% while Doppler CAD was 90%. Combined techniques of qualitative grey scale features and Doppler CAD assessment resulted in overall increased sensitivity (92%) and optimal specificity (85.1%). The experience of the CAD user, nodule size and the thyroid malignancy risk stratification system used for interpretation were the main potential factors affecting diagnostic performance outcomes. The diagnostic performance of CAD of thyroid ultrasound is comparable to that of qualitative visual assessment; however, combined techniques have the potential for better optimized diagnostic accuracy.

SELECTION OF CITATIONS
SEARCH DETAIL
...