ABSTRACT

Objectives: To assess the range of quantitative iodine values in renal cysts (RC) (with a few renal neoplasms [RNs] as a comparison) to develop an expected range of values for RC that can be used in future studies for their differentiation. Material and Methods: Consecutive patients (n = 140) with renal lesions who had undergone abdominal examination on a clinical photon-counting computed tomography (PCCT) were retrospectively included. Automated iodine quantification maps were reconstructed, and region of interest (ROI) measurements of iodine concentration (IC) (mg/cm3) were performed on whole renal lesions. In addition, for heterogeneous lesions, a secondary ROI was placed on the area most suspicious for malignancy. The discriminatory values of minimum, maximum, mean, and standard deviation for IC were compared using simple logistic regression and receiver operating characteristic curves (area under the curve [AUC]). Results: A total of 259 renal lesions (243 RC and 16 RN) were analyzed. There were significant differences between RC and RN for all IC measures with the best-performing metrics being mean and maximum IC of the entire lesion ROI (AUC 0.912 and 0.917, respectively) but also mean and minimum IC of the most suspicious area in heterogeneous lesions (AUC 0.983 and 0.992, respectively). Most RC fell within a range of low measured iodine values although a few had higher values. Conclusion: Automated iodine quantification maps reconstructed from clinical PCCT have a high diagnostic ability to differentiate RCs and neoplasms. The data from this pilot study can be used to help establish quantitative values for clinical differentiation of renal lesions.

4.
Pol J Radiol ; 89: e63-e69, 2024.
Article in English | MEDLINE | ID: mdl-38371894

ABSTRACT

Purpose: Computed tomography (CT) pulmonary angiography is considered the gold standard for pulmonary embolism (PE) diagnosis, relying on the discrimination between contrast and embolus. Photon-counting detector CT (PCD-CT) generates monoenergetic reconstructions through energy-resolved detection. Virtual monoenergetic images (VMI) at low keV can be used to improve pulmonary artery opacification. While studies have assessed VMI for PE diagnosis on dual-energy CT (DECT), there is a lack of literature on optimal settings for PCD-CT-PE reconstructions, warranting further investigation. Material and methods: Twenty-five sequential patients who underwent PCD-CT pulmonary angiography for suspicion of acute PE were retrospectively included in this study. Quantitative metrics including signal-to-noise ratio (SNR) and contrast-to-noise (CNR) ratio were calculated for 4 VMI values (40, 60, 80, and 100 keV). Qualitative measures of diagnostic quality were obtained for proximal to distal pulmonary artery branches by 2 cardiothoracic radiologists using a 5-point modified Likert scale. Results: SNR and CNR were highest for the 40 keV VMI (49.3 ± 22.2 and 48.2 ± 22.1, respectively) and were inversely related to monoenergetic keV. Qualitatively, 40 and 60 keV both exhibited excellent diagnostic quality (mean main pulmonary artery: 5.0 ± 0 and 5.0 ± 0; subsegmental pulmonary arteries 4.9 ± 0.1 and 4.9 ± 0.1, respectively) while distal segments at high (80-100) keVs had worse quality. Conclusions: 40 keV was the best individual VMI for the detection of pulmonary embolism by quantitative metrics. Qualitatively, 40-60 keV reconstructions may be used without a significant decrease in subjective quality. VMIs at higher keV lead to reduced opacification of the distal pulmonary arteries, resulting in decreased image quality.

5.
Emerg Radiol ; 31(1): 73-82, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38224366

ABSTRACT

PURPOSE: Acute chest syndrome (ACS) is secondary to occlusion of the pulmonary vasculature and a potentially life-threatening complication of sickle cell disease (SCD). Dual-energy CT (DECT) iodine perfusion map reconstructions can provide a method to visualize and quantify the extent of pulmonary microthrombi. METHODS: A total of 102 patients with sickle cell disease who underwent DECT CTPA with perfusion were retrospectively identified. The presence or absence of airspace opacities, segmental perfusion defects, and acute or chronic pulmonary emboli was noted. The number of segmental perfusion defects between patients with and without acute chest syndrome was compared. Sub-analyses were performed to investigate robustness. RESULTS: Of the 102 patients, 68 were clinically determined to not have ACS and 34 were determined to have ACS by clinical criteria. Of the patients with ACS, 82.4% were found to have perfusion defects with a median of 2 perfusion defects per patient. The presence of any or new perfusion defects was significantly associated with the diagnosis of ACS (P = 0.005 and < 0.001, respectively). Excluding patients with pulmonary embolism, 79% of patients with ACS had old or new perfusion defects, and the specificity for new perfusion defects was 87%, higher than consolidation/ground glass opacities (80%). CONCLUSION: DECT iodine map has the capability to depict microthrombi as perfusion defects. The presence of segmental perfusion defects on dual-energy CT maps was found to be associated with ACS with potential for improved specificity and reclassification.


Subject(s)
Acute Chest Syndrome , Anemia, Sickle Cell , Iodine , Pulmonary Embolism , Humans , Acute Chest Syndrome/diagnostic imaging , Retrospective Studies , Angiography/methods , Reproducibility of Results , Tomography, X-Ray Computed/methods , Lung , Pulmonary Embolism/diagnostic imaging , Anemia, Sickle Cell/complications , Anemia, Sickle Cell/diagnostic imaging , Perfusion
7.
Food Policy ; 121: 102546, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38130412

ABSTRACT

There is growing evidence on the impacts of site-specific nutrient management (SSNM) from Asia. The evidence for Sub-Saharan Africa (SSA), where SSNM developments are more recent and where conditions concerning soil fertility and fertilizer use differ importantly from those in Asia, is extremely scarce. We evaluate a SSNM advisory tool that allows extension agents to generate fertilizer recommendations tailored to the specific situation of an individual farmer's field, using a three-year randomized controlled trial with 792 smallholder farmers in the maize belt of northern Nigeria. Two treatment arms were implemented: T1 and T2 both provide SSNM information on nutrient use and management, but T2 provides additional information on maize price distributions and the associated variability of expected returns to fertilizer use. We estimate average and heterogenous intent-to-treat effects on agronomic, economic and environmental plot-level outcomes. We find that T1 and T2 lead to substantial increases (up to 116%) in the adoption of good fertilizer management practices and T2 leads to incremental increases (up to 18%) in nutrient application rates, yields and revenues. Both treatments improve low levels of nutrient use efficiency and reduce high levels of greenhouse gas emission intensity, after two years of treatment. Our findings underscore the possibility of a more gradual and sustainable intensification of smallholder agriculture in SSA, as compared with the Asian Green Revolution, through increased fertilizer use accompanied by improved fertilizer management.

8.
Clin Imaging ; 104: 110008, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37862910

ABSTRACT

PURPOSE: Photon-counting-detector computed tomography (PCD-CT) offers enhanced noise reduction, spatial resolution, and image quality in comparison to energy-integrated-detectors CT (EID-CT). These hypothesized improvements were compared using PCD-CT ultra-high (UHR) and standard-resolution (SR) scan-modes. METHODS: Phantom scans were obtained with both EID-CT and PCD-CT (UHR, SR) on an adult body-phantom. Radiation dose was measured and noise levels were compared at a minimum achievable slice thickness of 0.5 mm for EID-CT, 0.2 mm for PCD-CT-UHR and 0.4 mm for PCD-CT-SR. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for five tissue densities. Additionally, data from 25 patients who had PCD-CT of chest were reconstructed at 1 mm and 0.2 mm (UHR) slice-thickness and compared quantitatively (SNR) and qualitatively (noise, quality, sharpness, bone details). RESULTS: Phantom PCD-CT-UHR and PCD-CT-SR scans had similar measured radiation dose (16.0mGy vs 15.8 mGy). Phantom PCD-CT-SR (0.4 mm) had lower noise level in comparison to EID-CT (0.5 mm) (9.0HU vs 9.6HU). PCD-CT-UHR (0.2 mm) had slightly higher noise level (11.1HU). Phantom PCD-CT-SR (0.4 mm) had higher SNR in comparison to EID-CT (0.5 mm) while achieving higher resolution (Bone 115 vs 96, Acrylic 14 vs 14, Polyethylene 11 vs 10). SNR was slightly lower across all densities for PCD-CT UHR (0.2 mm). Interestingly, CNR was highest in the 0.2 mm PCD-CT group; PCD-CT CNR was 2.45 and 2.88 times the CNR for 0.5 mm EID-CT for acrylic and poly densities. Clinical comparison of SNR showed predictably higher SNR for 1 mm (30.3 ± 10.7 vs 14.2 ± 7, p = 0.02). Median subjective ratings were higher for 0.2 mm UHR vs 1 mm PCD-CT for nodule contour (4.6 ± 0.3 vs 3.6 ± 0.1, p = 0.02), bone detail (5 ± 0 vs 4 ± 0.1, p = 0.001), image quality (5 ± 0.1 vs 4.6 ± 0.4, p = 0.001), and sharpness (5 ± 0.1 vs 4 ± 0.2). CONCLUSION: Both UHR and SR PCD-CT result in similar radiation dose levels. PCD-CT can achieve higher resolution with lower noise level in comparison to EID-CT.


Subject(s)
Photons , Tomography, X-Ray Computed , Adult , Humans , Tomography, X-Ray Computed/methods , Lung , Radiation Dosage , Signal-To-Noise Ratio , Phantoms, Imaging
9.
Pol J Radiol ; 88: e423-e429, 2023.
Article in English | MEDLINE | ID: mdl-37808170

ABSTRACT

Purpose: Left atrial calcification (LAC), a primarily radiologic diagnosis, has been associated with rheumatic heart disease (RHD) and rheumatic fever (RF). However, left atrial calcification continues to be observed despite a significant decrease in the prevalence of rheumatic heart disease. The purpose of this study was to investigate other possible etiologies of left atrial calcification. Material and methods: This retrospective, observational single-center study included patients from 2017 to 2022 identified as having left atrial calcification as well as age- and sex-matched controls. The prevalence of rheumatic heart disease, atrial ablation, and mitral valve disease was compared, and odds ratios were calculated for each independent variable. Results: Sixty-two patients with left atrial calcifications were included and compared with 62 controls. 87.1% of patients in the left atrial calcifications cohort had a history of atrial fibrillation compared with 21% in the control cohort (p < 0.001). 16.1% of patients in the calcifications cohort presented a history of rheumatic fever compared with zero in the control cohort (p = 0.004). 66.1% of the left atrial calcifications cohort had a history of atrial ablation compared with 6.5% of the control group (p < 0.001). The odds ratio for left atrial calcification was 19.0 vs. 4.8 for rheumatic fever (comparative odds = 4.0 for atrial ablation vs. rheumatic fever). Multivariable log model found atrial ablation to explain 79.8% of left atrial calcifications identified. Conclusions: Our study found a 4-fold higher association between history of atrial ablation and left atrial calcification compared with rheumatic heart disease, suggesting a potential shift in etiology.

10.
Comput Electron Agric ; 212: None, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37705720

ABSTRACT

While many have extolled the potential impacts of digital advisory services for smallholder agriculture, the evidence for sustained uptake of such tools remains limited. This paper utilizes a survey of tool developers and researchers, as well as a systematic meta-analysis of prior studies, to assess the extent and challenges of scaling decision support tools for site-specific soil nutrient management (SSNM-DST) across smallholder farming systems, where "scaling" is defined as a significant increase in tool usage beyond pilot levels. Our evaluation draws on relevant literature, expert opinion and apps available in different repositories. Despite their acclaimed yield benefits, we find that SSNM-DST have struggled to reach scale over the last few decades and, with strong heterogeneity in adoption among intended stakeholders and tools. For example, the log odds of a SSNM-DST reaching 5-10 % of the target farmers compared with reaching none, decreases by âˆ¼200% when a technical problem is stated as a reason for the tools' failure to be used at scale. We find a similar decrease in odds ratios when technical, socioeconomic, policy, and R&D constraints were identified as barriers to scaling by national extension and private systems. Meta-regression analysis indicates that the response ratio of using SSNM-DST over Farmer Fertilizer Practice (FFP) varies by non-tool related covariates, such as initial crop yield potential under FFP, current and past crop types, acidity class of the soil, temperature and rainfall regimes, and the amount of input under FFP. In general, the SSNM-DST have moved one step forward compared with the traditional 'blanket' fertilizer recommendation by accounting for in-field heterogeneities in soil and crop characteristics, while remaining undifferentiated in terms of demographic and socioeconomic heterogeneities among users, which potentially constrains adoption at scale. The SSNM-DSTs possess reasonable applicability and can be labeled 'ready' from purely scientific viewpoints, although their readiness for system-level uptake at scale remains limited, especially where socio-technical and institutional constraints are prevalent.

11.
Acta Radiol ; 64(10): 2722-2730, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37649280

ABSTRACT

BACKGROUND: Detecting occlusions of coronary artery bypass grafts using non-contrast computed tomography (CT) series is understudied and underestimated. PURPOSE: To evaluate morphological findings for the diagnosis of chronic coronary artery bypass graft occlusion on non-contrast CT and investigate performance statistics for potential use cases. MATERIAL AND METHODS: Seventy-three patients with coronary artery bypass grafts who had CT angiography of the chest (non-contrast and arterial phases) were retrospectively included. Two readers applied pre-set morphologic findings to assess the patency of a bypass graft on non-contrast series. These findings included vessel shape (linear-band like), collapsed lumen and surgical graft marker without a visible vessel. Performance was tested using the simultaneously acquired arterial phase series as the ground truth. RESULTS: The per-patient diagnostic accuracy for occlusion was 0.890 (95% confidence interval = 0.795-0.951). Venous grafts overall had an 88% accuracy. None of the left internal mammary artery to left anterior descending artery arterial graft occlusions were detected. The negative likelihood ratio for an occluded graft that is truly patent was 0.121, demonstrating a true post-test probability of 97% for identifying a patent graft as truly patent given a prevalence of 20% occlusion at a median 8.4 years post-surgery. Neither years post-surgery, nor number of vessels was associated with a significant decrease in reader accuracy. CONCLUSION: Evaluation of coronary bypass grafts for chronic occlusion on non-contrast CT based off vessel morphology is feasible and accurate for venous grafts. Potential use cases include low-intermediate risk patients with chest pain or shortness of breath for whom non-contrast CT was ordered, or administration of iodine-based contrast is contraindicated.


Subject(s)
Coronary Artery Bypass , Tomography, X-Ray Computed , Humans , Retrospective Studies , Coronary Angiography/methods , Vascular Patency , Sensitivity and Specificity , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Tomography, X-Ray Computed/methods , Graft Occlusion, Vascular/diagnostic imaging
13.
Clin Imaging ; 100: 24-29, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37167806

ABSTRACT

RATIONALE: Single-photon-emission-computerized-tomography/computed-tomography(SPECT/CT) is commonly used for pulmonary disease. Scant work has been done to determine ability of AI for secondary findings using low-dose-CT(LDCT) attenuation correction series of SPECT/CT. METHODS: 120 patients with ventilation-perfusion-SPECT/CT from 9/1/21-5/1/22 were included in this retrospective study. AI-RAD companion(VA10A,Siemens-Healthineers, Erlangen, Germany), an ensemble of deep-convolutional-neural-networks was evaluated for the detection of pulmonary nodules, coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss. Accuracy, sensitivity, specificity was measured for the outcomes. Inter-rater reliability were measured. Inter-rater reliability was measured using the intraclass correlation coefficient (ICC) by comparing the number of nodules identified by the AI to radiologist. RESULTS: Overall per-nodule accuracy, sensitivity, and specificity for detection of lung nodules were 0.678(95%CI 0.615-0.732), 0.956(95%CI 0.900-0.985), and 0.456(95%CI 0.376-0.543), respectively, with an intraclass correlation coefficient (ICC) between AI and radiologist of 0.78(95%CI 0.71-0.83). Overall per-patient accuracy for AI detection of coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.939(95%CI 0.878-0.975), 0.974(95%CI 0.925-0.995), and 0.857(95%CI 0.781-0.915), respectively. Sensitivity for coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.898(95%CI 0.778-0.966), 1 (95%CI 0.958-1), and 1 (95%CI 0.961-1), respectively. Specificity for coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.969(95% CI 0.893-0.996), 0.897 (95% CI 0.726-0.978), and 0.346 (95% CI 0.172-0.557), respectively. CONCLUSION: AI ensemble was accurate for coronary artery calcium and aortic ectasia/aneurysm, while sensitive for aortic ectasia/aneurysm, lung nodules and vertebral height loss on LDCT attenuation correction series of SPECT/CT.


Subject(s)
Artificial Intelligence , Calcium , Humans , Retrospective Studies , Dilatation, Pathologic , Reproducibility of Results , Tomography, Emission-Computed, Single-Photon , Tomography, X-Ray Computed , Lung , Perfusion
14.
Acta Radiol ; 64(8): 2357-2362, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37157189

ABSTRACT

BACKGROUND: Evaluation for gastrointestinal leak is a frequent imaging indication, and dual-energy computed tomography (DECT) with oral or rectally administered contrast can be used to improve efficiency and diagnostic confidence. PURPOSE: To assess the value of the DECT iodine overlay (IO) reconstruction as a stand-alone image set compared to routine CT in assessing oral or rectal contrast leak from the gastrointestinal system. MATERIAL AND METHODS: A blinded, retrospective audit study was performed by three readers who each interpreted 50 studies performed for assessment of oral or rectal contrast leak that were acquired using DECT. Each reader independently assessed both the routine CT images and the images of the reconstructed IO for contrast leak in random order with a six-week "wash-out period" between readings. Clinical follow-up provided the reference standard. Readers recorded the presence/absence of a leak, diagnostic confidence, image quality score, and interpretation time for each image set. RESULTS: Pooled data for overall accuracy in identification of a leak increased from 0.81 (95% confidence interval [CI]=0.74-0.87) for routine CT to 0.91 (95% CI=0.85-0.95) with IO, and the area under the curve (AUC) was significantly higher for IO than routine CT (P = 0.015). Readers required significantly less time to interpret IO than routine CT (median improvement of 12.5 s per image using pooled data; P < 0.001) while maintaining diagnostic confidence and perceived image quality. CONCLUSION: Use of DECT IO reconstructions for identification of oral or rectal contrast leak requires less time to interpret than routine CT with improved accuracy and maintained diagnostic confidence and perceived image quality.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Humans , Tomography, X-Ray Computed/methods , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Gastrointestinal Tract , Contrast Media
15.
Int J Cardiovasc Imaging ; 39(8): 1535-1546, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37148449

ABSTRACT

Noninvasive identification of active myocardial inflammation in patients with cardiac sarcoidosis plays a key role in management but remains elusive. T2 mapping is a proposed solution, but the added value of quantitative myocardial T2 mapping for active cardiac sarcoidosis is unknown. Retrospective cohort analysis of 56 sequential patients with biopsy-confirmed extracardiac sarcoidosis who underwent cardiac MRI for myocardial T2 mapping. The presence or absence of active myocardial inflammation in patients with CS was defined using a modified Japanese circulation society criteria within one month of MRI. Myocardial T2 values were obtained for the 16 standard American Heart Association left ventricular segments. The best model was selected using logistic regression. Receiver operating characteristic curves and dominance analysis were used to evaluate the diagnostic performance and variable importance. Of the 56 sarcoidosis patients included, 14 met criteria for active myocardial inflammation. Mean basal T2 value was the best performing model for the diagnosis of active myocardial inflammation in CS patients (pR2 = 0.493, AUC = 0.918, 95% CI 0.835-1). Mean basal T2 value > 50.8 ms was the most accurate threshold (accuracy = 0.911). Mean basal T2 value + JCS criteria was significantly more accurate than JCS criteria alone (AUC = 0.981 vs. 0.887, p = 0.017). Quantitative regional T2 values are independent predictors of active myocardial inflammation in CS and may add additional discriminatory capability to JCS criteria for active disease.


Subject(s)
Cardiomyopathies , Myocarditis , Sarcoidosis , Humans , Retrospective Studies , East Asian People , Predictive Value of Tests , Magnetic Resonance Imaging , Inflammation
16.
PLoS One ; 18(1): e0280230, 2023.
Article in English | MEDLINE | ID: mdl-36634099

ABSTRACT

Acid soils are a major constraint to agricultural productivity in many parts of sub-Saharan Africa, including Ethiopia. Restoring soil pH to optimal ranges for agriculture can have a significant impact on yields, particularly for acid intolerant crops like wheat and barley. The application of agricultural lime is the standard corrective, although the large application requirements, lack of farmer awareness, and weak or non-existent lime supply chains make this a complex problem to address at scale. To date, no large-scale farmer trials of lime application have been undertaken in Ethiopia. This leaves open the question to local policy makers as to the economic benefits given the enormous capital and logistics investments required. To help address this we leverage existing spatial edaphic data and longitudinal crop surveys to simulate the productivity impact of varying lime and fertilizer applications. Our estimates find the impact of moving pH from 5.5 to 6.5, modeled as a lime soil remediation strategy, increases yields by 22% and 19% for wheat and barley, respectively. In addition, at lower pH levels our models indicate that commonly used nitrogen-based fertilizers are less cost-effective. For wheat in highly acidic soils, we find that fertilizers cost over two times as much as a single application of lime over a five-year period. The cost savings of the use of lime reaches as high as 121% of average one-year agricultural household income for wheat; with barley these savings are lower but still substantial at 24%. In general, we advocate for an integrated soil fertility management strategy that applies appropriate levels of fertilizer on pH balanced soil. If successful, Ethiopia's acid soil reclamation could become a modest version of Brazil's successful "cerrado miracle" and serve as an example for Africa.


Subject(s)
Edible Grain , Soil , Fertilizers , Cost-Benefit Analysis , Ethiopia , Agriculture
17.
Visc Med ; 38(4): 288-294, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36160820

ABSTRACT

Background: The purpose of this study was to develop and validate reliable computed tomography (CT) imaging criteria for the diagnosis of gastric band slippage. Material and Methods: We retrospectively evaluated 67 patients for gastric band slippage using CT. Of these, 14 had surgically proven gastric band slippage (study group), 22 had their gastric bands removed for reasons other than slippage (control group 1), and 31 did not require removal (control group 2). All of the studies were read independently by two radiologists in a blinded fashion. The "O" sign, phi angle, amount of inferior displacement from the esophageal hiatus, and gastric pouch size were used to create CT diagnostic criteria. Standard statistical methods were used. Results: There was good overall interobserver agreement for diagnosis of gastric band slippage using CT diagnostic criteria (kappa = 0.83). Agreement was excellent for the "O" sign (kappa = 0.93) and phi angle (intraclass correlation coefficient = 0.976). The "O" sign, inferior displacement from the hiatus >3.5 cm, and gastric pouch volume >55 cm3 each had 100% positive predictive value. A phi angle <20° or >60° had the highest negative predictive value (NPV) (98%). Of all CT diagnostic criteria, enlarged gastric pouch size was most correlated with band slippage with an AUC of 0.991. Conclusion: All four imaging parameters were useful in evaluating for gastric band slippage on CT, with good interobserver agreement. Of these parameters, enlarged gastric pouch size was most correlated with slippage and abnormal phi angle had the highest NPV.

18.
Cureus ; 14(7): e27037, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35989840

ABSTRACT

Vascular spasm is well known and studied in the arterial system. There are only a few cases reported related to central venous spasms. We present the case of a 63-year-old male with an extensive medical history, including deep vein thrombosis (DVT), who underwent peripheral insertion of a central catheter in his left upper extremity with subsequent development of left upper extremity edema. The central catheter was removed before the patient underwent a contrast-enhanced computed tomography of the chest which revealed severe narrowing of the left brachiocephalic vein, consistent with venospasm in the clinical setting. Nitroglycerin might be useful to prevent vasospasm, or it might also be used for treatment. In our case, the catheter was removed, and no subsequent treatment was necessary.

19.
BMC Infect Dis ; 22(1): 637, 2022 Jul 21.
Article in English | MEDLINE | ID: mdl-35864468

ABSTRACT

BACKGROUND: Airspace disease as seen on chest X-rays is an important point in triage for patients initially presenting to the emergency department with suspected COVID-19 infection. The purpose of this study is to evaluate a previously trained interpretable deep learning algorithm for the diagnosis and prognosis of COVID-19 pneumonia from chest X-rays obtained in the ED. METHODS: This retrospective study included 2456 (50% RT-PCR positive for COVID-19) adult patients who received both a chest X-ray and SARS-CoV-2 RT-PCR test from January 2020 to March of 2021 in the emergency department at a single U.S. INSTITUTION: A total of 2000 patients were included as an additional training cohort and 456 patients in the randomized internal holdout testing cohort for a previously trained Siemens AI-Radiology Companion deep learning convolutional neural network algorithm. Three cardiothoracic fellowship-trained radiologists systematically evaluated each chest X-ray and generated an airspace disease area-based severity score which was compared against the same score produced by artificial intelligence. The interobserver agreement, diagnostic accuracy, and predictive capability for inpatient outcomes were assessed. Principal statistical tests used in this study include both univariate and multivariate logistic regression. RESULTS: Overall ICC was 0.820 (95% CI 0.790-0.840). The diagnostic AUC for SARS-CoV-2 RT-PCR positivity was 0.890 (95% CI 0.861-0.920) for the neural network and 0.936 (95% CI 0.918-0.960) for radiologists. Airspace opacities score by AI alone predicted ICU admission (AUC = 0.870) and mortality (0.829) in all patients. Addition of age and BMI into a multivariate log model improved mortality prediction (AUC = 0.906). CONCLUSION: The deep learning algorithm provides an accurate and interpretable assessment of the disease burden in COVID-19 pneumonia on chest radiographs. The reported severity scores correlate with expert assessment and accurately predicts important clinical outcomes. The algorithm contributes additional prognostic information not currently incorporated into patient management.


Subject(s)
COVID-19 , Deep Learning , Adult , Artificial Intelligence , COVID-19/diagnostic imaging , Humans , Prognosis , Radiography, Thoracic , Retrospective Studies , SARS-CoV-2 , Tomography, X-Ray Computed , X-Rays
20.
Acad Radiol ; 29(8): 1178-1188, 2022 08.
Article in English | MEDLINE | ID: mdl-35610114

ABSTRACT

RATIONALE AND OBJECTIVES: The burden of coronavirus disease 2019 (COVID-19) airspace opacities is time consuming and challenging to quantify on computed tomography. The purpose of this study was to evaluate the ability of a deep convolutional neural network (dCNN) to predict inpatient outcomes associated with COVID-19 pneumonia. MATERIALS AND METHODS: A previously trained dCNN was tested on an external validation cohort of 241 patients who presented to the emergency department and received a chest computed tomography scan, 93 with COVID-19 and 168 without. Airspace opacity scoring systems were defined by the extent of airspace opacity in each lobe, totaled across the entire lungs. Expert and dCNN scores were concurrently evaluated for interobserver agreement, while both dCNN identified airspace opacity scoring and raw opacity values were used in the prediction of COVID-19 diagnosis and inpatient outcomes. RESULTS: Interobserver agreement for airspace opacity scoring was 0.892 (95% CI 0.834-0.930). Probability of each outcome behaved as a logistic function of the opacity scoring (25% intensive care unit admission at score of 13/25, 25% intubation at 17/25, and 25% mortality at 20/25). Length of hospitalization, intensive care unit stay, and intubation were associated with larger airspace opacity score (p = 0.032, 0.039, 0.036, respectively). CONCLUSION: The tested dCNN was highly predictive of inpatient outcomes, performs at a near expert level, and provides added value for clinicians in terms of prognostication and disease severity.


Subject(s)
COVID-19 , Deep Learning , Algorithms , COVID-19/diagnostic imaging , COVID-19 Testing , Humans , Inpatients , Lung/diagnostic imaging , Morbidity , Retrospective Studies , SARS-CoV-2 , Tomography, X-Ray Computed/methods