Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 68
Filter
1.
Zhonghua Er Ke Za Zhi ; 56(2): 116-121, 2018 Feb 02.
Article in Chinese | MEDLINE | ID: mdl-29429199

ABSTRACT

Objective: To examine the impact of maternal risky behaviors on the behaviors of children born to adolescent and young mothers. Methods: Adolescents and young Chinese mothers were recruited from an integrated young mother supportive program in Hong Kong between January and June 2015. Eligible mothers were asked to complete a questionnaire on their sociodemographic characteristics and history of risky behavior as well as their children's behaviors. Multiple regression analyses were conducted to explore the association between maternal risky behaviors and their children's behaviors. Results: Among 201 respondents, there were 187 (93.0%) ex-drinkers, 136 (67.7%) ex-smokers, and 83 (41.3%) ex-addicts. Compared to the reference group, children of mothers with drug use behaviors were more likely to have abnormal SDQ total difficulties scores (odds ratio 2.60, P=0.01), those of ex-drinking mothers had more behavioral difficulties and more conduct problems (B=3.82 and 1.37, P both=0.01) and those of ex-smoking mothers had more conduct problems (B=0.74, P=0.01) after adjustment for confounders. Children of active drug-taking mothers also had more emotional symptoms (B=1.77, P=0.04) and hyperactivity/inattention problems (B=2.14, P=0.03). Conclusion: The history of mother's risky behavior was significantly associated with the behavioral problems of the children.


Subject(s)
Child Behavior Disorders , Child Behavior , Mother-Child Relations , Pregnancy in Adolescence , Adolescent , Child , Child, Preschool , Female , Humans , Mothers , Odds Ratio , Pregnancy , Risk Factors , Surveys and Questionnaires , Young Adult
3.
Ultrasound Obstet Gynecol ; 30(3): 275-80, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17721863

ABSTRACT

OBJECTIVES: Congenital heart disease is associated with high mortality and morbidity rates, being the most life-threatening defect in the first month of postnatal life and accounting for approximately half of all childhood mortality from birth defects. Despite this, the prenatal detection rate for congenital outflow tract anomalies by ultrasound imaging is relatively low. The aim of this study was to establish a nomogram for the pulmonary artery/aorta (PA/AO) ratio measured in the three-vessel view plane. This ratio was investigated as a simple screening tool for congenital cardiac outflow tract abnormalities. METHODS: The study was a prospective evaluation of 966 singleton fetuses at 16-24 weeks of gestation and 46 fetuses with congenital cardiac outflow tract abnormalities. The diameters of the pulmonary artery and aorta were measured in the three-vessel view. The PA/AO ratio was calculated and a nomogram was constructed. The mean and 95% CI for the ratio were defined and the PA/AO ratios of cases with outflow tract abnormalities were plotted against the values for normal fetuses. RESULTS: The gestational age of the normal group ranged from 16 to 24 weeks, with a median of 19 weeks. The pulmonary artery diameter measured between 2.1 and 4.93 mm (mean, 3.3 mm) and the aorta measured between 2.1 and 5.2 mm (mean, 2.93 mm). The mean (SD) PA/AO ratio was 1.16 (0.18) (95% CI, 0.87-1.58; range 0.61-1.86; median, 1.14). For fetuses with outflow tract abnormalities, the median gestation was 19 weeks and 37/43 (86%) had a PA/AO ratio outside the 95% CI. CONCLUSIONS: The PA/AO ratio derived from measurements in the three-vessel view plane can be used as an initial screening tool for outflow tract anomalies and may have a sensitivity of up to 86%, with a 5% false-positive rate.


Subject(s)
Aorta/diagnostic imaging , Fetal Diseases/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Aorta/embryology , Aorta/pathology , Female , Fetal Heart/diagnostic imaging , Gestational Age , Heart Defects, Congenital/pathology , Humans , Mass Screening/methods , Observer Variation , Pregnancy , Pregnancy Trimester, Second , Prospective Studies , Pulmonary Artery/embryology , Pulmonary Artery/pathology , Ultrasonography, Prenatal/methods
4.
Cochrane Database Syst Rev ; (2): CD004075, 2007 Apr 18.
Article in English | MEDLINE | ID: mdl-17443538

ABSTRACT

BACKGROUND: Pulse oximetry could contribute to the evaluation of fetal well-being during labour. OBJECTIVES: To compare the effectiveness and safety of fetal pulse oximetry with conventional surveillance techniques. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (November 2006), MEDLINE (1994 to November 2006), EMBASE (1994 to November 2006) and Current Contents (1994 to November 2006). SELECTION CRITERIA: All published and unpublished randomised controlled trials that compared maternal and fetal outcomes when fetal pulse oximetry was used in labour, with or without concurrent use of conventional fetal surveillance, compared with using cardiotocography (CTG) alone. DATA COLLECTION AND ANALYSIS: At least two independent authors performed data extraction. Analyses were performed on an intention-to-treat basis. We sought additional information from the investigators of three of the reported trials. MAIN RESULTS: Five published trials comparing fetal pulse oximetry and CTG with CTG alone (or when fetal pulse oximetry values were blinded) were included. The published trials, with some unpublished data, reported on a total of 7424 pregnancies. Differing entry criteria necessitated separate analyses, rather than meta-analysis of all trials. Four trials reported no significant differences in the overall caesarean section rate between those monitored with fetal oximetry and those not monitored with fetal pulse oximetry or for whom the fetal pulse oximetry results were masked. Neonatal seizures and hypoxic ischemic encephalopathy were rare. No studies reported details of assessment of long-term disability. There was a statistically significant decrease in caesarean section for nonreassuring fetal status in the fetal pulse oximetry plus CTG group compared to the CTG group in two analyses: (i) gestation from 36 weeks with fetal blood sample (fetal blood sampling) not required prior to study entry (relative risk (RR) 0.68, 95% confidence interval (CI) 0.47 to 0.99); and (ii) when fetal blood sampling was required prior to study entry (RR 0.03, 95% CI 0.00 to 0.44). There was no statistically significant difference in caesarean section for dystocia when fetal pulse oximetry (fetal pulse oximetry) was added to CTG monitoring, compared with CTG monitoring alone, although the incidence rates varied between the trials. AUTHORS' CONCLUSIONS: The data provide limited support for the use of fetal pulse oximetry when used in the presence of a nonreassuring CTG, to reduce caesarean section for nonreassuring fetal status. The addition of fetal pulse oximetry does not reduce overall caesarean section rates. A better method to evaluate fetal well-being in labour is required.


Subject(s)
Fetal Monitoring/methods , Oximetry/methods , Cardiotocography , Cesarean Section , Delivery, Obstetric/statistics & numerical data , Female , Humans , Oximetry/adverse effects , Pregnancy
5.
Ultrasound Obstet Gynecol ; 28(7): 934-8, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17083144

ABSTRACT

OBJECTIVE: To assess the effect of glucose control on the rate of growth of fetuses in women with pregestational diabetes mellitus (Types 1 and 2). METHODS: All pregestational diabetic women booked at Mater Mothers' Hospital, Brisbane, Australia, between 1 January 1994 and 31 December 2002, were included. Pregnancies with congenital fetal anomalies, multiple pregnancies, and pregnancies terminated prior to 20 weeks' gestation were excluded. Dating scans were performed before 14 weeks' gestation and serial scans were performed at 18, 24, 28, 32 and 36 weeks. Fetal parameters, including biparietal diameter, femur length and abdominal circumference, were recorded. The daily growth rates for biparietal diameter, femur length, and fetal abdominal area were calculated and compared with those in a low-risk (non-diabetic) population. The growth rates in fetuses of women with satisfactory diabetic control (HbA1c < 6.5%) and unsatisfactory control (HbA1c > or = 6.5%) in the three trimesters were compared. RESULTS: A total of 174 diabetic pregnancies were included and a total of 997 ultrasound scans were performed. The growth rates for fetuses of mothers with diabetes mellitus were significantly higher than for those in the low-risk population. The z-scores for biparietal diameter, femur length, and fetal abdominal area were 0.18, 0.59 and 1.44, respectively. Fetuses of diabetic mothers with high HbA1c in the first trimester had significantly greater fetal abdominal area growth rate than those with normal HbA1c (fetal abdominal area z-score of 1.7 vs. 0.75, P = 0.009). Although the fetal abdominal area z-scores in fetuses of diabetic mothers with high HbA1c in the second or third trimesters were also higher than those with normal HbA1c levels, the differences did not reach statistical significance. Maternal obesity did not influence the fetal growth rate. CONCLUSION: The rate of growth of fetuses of diabetic mothers differs from that of the normal population. Growth acceleration persists until the late third trimester. Moreover, periconceptional glucose control appears to have a significant effect on accelerated growth of the fetal abdominal area.


Subject(s)
Fetal Development/physiology , Pregnancy in Diabetics/physiopathology , Prenatal Diagnosis/statistics & numerical data , Adult , Analysis of Variance , Female , Fetal Macrosomia/diagnostic imaging , Fetal Macrosomia/etiology , Gestational Age , Humans , Infant, Newborn , Middle Aged , Pregnancy , Ultrasonography
6.
Cochrane Database Syst Rev ; (4): CD004075, 2004 Oct 18.
Article in English | MEDLINE | ID: mdl-15495078

ABSTRACT

BACKGROUND: Fetal pulse oximetry (FPO) may contribute to the evaluation of fetal well-being during labour. OBJECTIVES: To compare the effectiveness and safety of FPO with conventional surveillance techniques, using the results of randomised controlled trials. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group trials register (31 July 2004) and conducted a systematic literature search of MEDLINE (1994 to July 2004), EMBASE (1994 to July 2004) and Current Contents (1994 to July 2004). SELECTION CRITERIA: All published and unpublished randomised controlled trials (RCTs) that compared maternal and fetal/neonatal/infant outcomes when FPO was used in labour, with or without concurrent use of conventional fetal surveillance, compared with using cardiotocography (CTG) alone. DATA COLLECTION AND ANALYSIS: Two independent reviewers performed data extraction. Analyses were performed on an intention-to-treat basis. We sought additional information from the investigators of the one reported trial. MAIN RESULTS: One published RCT (comparing FPO and CTG with CTG alone) was included; and two ongoing RCTs were identified. The single included RCT reported on 1010 cases. Unpublished pilot data were available for some outcomes to give a total of 1190 cases. There was no difference in the overall caesarean section rate between the two groups (relative risk (RR) 1.12, 95% confidence interval (CI) 0.91 to 1.37). There were less caesarean sections for nonreassuring fetal status in the FPO plus CTG group compared with the CTG only group (RR 0.45, 95% CI 0.28 to 0.72). The only reported neonatal seizure occurred in the CTG only group (RR 0.29 95% CI 0.01 to 7.08). Use of FPO with CTG decreased operative delivery (caesarean section, forceps, vacuum) for nonreassuring fetal status (RR 0.71, 95% CI 0.55 to 0.93) compared with CTG alone. No differences were seen for overall operative deliveries, endometritis, intrapartum or postpartum haemorrhage, uterine rupture, low Apgar scores, umbilical arterial pH or base excess, admission to the neonatal intensive care unit or fetal/neonatal death. REVIEWERS' CONCLUSIONS: The one published RCT reported that FPO decreased the caesarean section rate and operative delivery rates for nonreassuring fetal status, without adversely affecting maternal or fetal/neonatal outcomes. However, no difference was seen in the overall caesarean section (CS) or operative delivery rates because more CS were performed for dystocia in the FPO group. Further RCTs may address dystocia in labours monitored with FPO, maternal satisfaction with fetal monitoring and labour, long-term neurodevelopmental outcome of infants who exhibited nonreassuring fetal status in labour and costs of FPO.


Subject(s)
Fetal Monitoring/methods , Oximetry/methods , Cardiotocography , Delivery, Obstetric/statistics & numerical data , Humans
8.
J Paediatr Child Health ; 40(1-2): 63-5, 2004.
Article in English | MEDLINE | ID: mdl-14718009

ABSTRACT

Accurate clinical diagnosis of severe acute respiratory syndrome (SARS) based on the current World Health Organization definition is difficult and at times impossible at the early stage of the disease. Both false positive and false negative cases are commonly encountered and this could have far-reaching detrimental effects on the patients, their family and the clinicians alike. Contact history is particularly important in diagnosing SARS in children as their presenting features are often non-specific. The difficulty in making a correct diagnosis is further compounded by the lack of a sensitive rapid diagnostic test. Serology is not particularly helpful in the initial triaging of patients as it takes at least 3 weeks to become positive. Co-infection and other treatable conditions should not be missed and conventional antibiotics should remain as part of the first-line treatment regimen. We report five cases to illustrate the difficulties and dilemmas faced by clinicians in diagnosing SARS in children.


Subject(s)
Severe Acute Respiratory Syndrome/diagnosis , Adolescent , Child , Child, Preschool , Diagnosis, Differential , Humans , Lung/diagnostic imaging , Male , Radiography, Thoracic , Reverse Transcriptase Polymerase Chain Reaction/methods , Severe Acute Respiratory Syndrome/physiopathology , Severity of Illness Index
9.
Ergonomics ; 46(13-14): 1386-407, 2003.
Article in English | MEDLINE | ID: mdl-14612327

ABSTRACT

Usability and affective issues of using automatic speech recognition technology to interact with an automated teller machine (ATM) are investigated in two experiments. The first uncovered dialogue patterns of ATM users for the purpose of designing the user interface for a simulated speech ATM system. Applying the Wizard-of-Oz methodology, multiple mapping and word spotting techniques, the speech driven ATM accommodates bilingual users of Bahasa Melayu and English. The second experiment evaluates the usability of a hybrid speech ATM, comparing it with a simulated manual ATM. The aim is to investigate how natural and fun can talking to a speech ATM be for these first-time users. Subjects performed the withdrawal and balance enquiry tasks. The ANOVA was performed on the usability and affective data. The results showed significant differences between systems in the ability to complete the tasks as well as in transaction errors. Performance was measured on the time taken by subjects to complete the task and the number of speech recognition errors that occurred. On the basis of user emotions, it can be said that the hybrid speech system enabled pleasurable interaction. Despite the limitations of speech recognition technology, users are set to talk to the ATM when it becomes available for public use.


Subject(s)
Ergonomics/psychology , Speech , User-Computer Interface , Analysis of Variance , Equipment Design , Ergonomics/instrumentation , Female , Humans , Male , Sex Factors , Task Performance and Analysis
10.
Gynecol Obstet Invest ; 56(2): 113-6, 2003.
Article in English | MEDLINE | ID: mdl-12939561

ABSTRACT

OBJECTIVE: Cardiac impairment is frequently found in babies of diabetic mothers. It is still controversial whether this is due to poor glucose control. The aim of this study is to compare the cardiac function in fetuses of well- and poorly-controlled pre-gestational diabetic pregnancy in third trimester. METHODS: Women with type 1 pre-gestational diabetes were enrolled at 30-32 weeks. Cardiac size and interventricular septal wall thickness were measured by M-mode at end-diastolic phase. The right and left ventricular ejection fractions were calculated. At the mitral and tricuspid valves inflow, the ratio between early ventricular filling and active atrial filling (E/A) at both atrioventricular valves were measured by Doppler echocardiography. Peak velocities of ascending aorta and pulmonary artery were assessed. The angle of isonation was kept at <20 degrees. Women with poorly-controlled diabetes (HbA1c>6.5%) were compared with those with satisfactorily controlled diabetes (HbA1c < or = 6.5%). RESULTS: A total of 21 women with pre-gestational diabetes were recruited for this study. Eight women with well-controlled diabetes were compared with 9 women who had poorly-controlled diabetes. HbA1c in the poorly-controlled group was 7.3% and in the well-controlled group it was 5.4% (p<0.001). There was no difference between the two groups in cardiac size, interventricular septal wall thickness, ejection fraction, aorta and pulmonary artery peak flow velocities. The right atrioventricular E/A ratio was significantly lower among the poorly-controlled diabetic pregnancies (0.71 vs. 0.54; p<0.05). CONCLUSION: Fetuses of poorly-controlled diabetic mothers had a lower right atrioventricular E/A ratio. This may be due to metabolic acidosis, non-hypertrophic cardiac dysfunction or fetal polycythemia.


Subject(s)
Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 1/therapy , Fetal Heart/physiopathology , Pregnancy in Diabetics/complications , Pregnancy in Diabetics/therapy , Diabetes Mellitus, Type 1/blood , Female , Fetal Heart/diagnostic imaging , Gestational Age , Glycated Hemoglobin/analysis , Heart Atria/diagnostic imaging , Heart Atria/embryology , Heart Atria/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/embryology , Heart Ventricles/physiopathology , Humans , Pregnancy , Pregnancy in Diabetics/blood , Prospective Studies , Ultrasonography
11.
Genet Test ; 7(1): 1-6, 2003.
Article in English | MEDLINE | ID: mdl-12820695

ABSTRACT

We report genetic characterization of isochromosome 18p using a combination of cytogenetic and molecular genetic methods, including multiplex fluorescent PCR. The patient was referred for chorionic villus sampling (CVS) due to advanced maternal age and maternal anxiety. The placental karyotype was 47,XX,+mar, with the marker having the appearance of a small supernumerary isochromosome. Because differentiating between isochromosomes and other structural rearrangements is normally very difficult, a variety of genetic tests including fluorescence in situ hybridization (FISH), PCR, and multiplex fluorescent PCR were undertaken to determine chromosomal origin and copy number and, thus, allow accurate diagnosis of the corresponding syndrome. FISH determined that the marker chromosome contained chromosome 18 material. PCR of a variety of short tandem repeats (STRs) confirmed that there was at least one extra copy of the maternal 18p material. However, neither FISH nor PCR could accurately determine copy number. Multiplex fluorescent PCR (MF-PCR) of STRs simultaneously determined that: (1) the marker included 18p material; (2) the marker was maternal in origin; (3) allele copy number indicated tetrasomy; and (4) contamination of the sample could be ruled out. Results were also rapid with accurate diagnosis of the syndrome tetrasomy 18p possible within 5 hours.


Subject(s)
Aneuploidy , Chromosomes, Human, Pair 18/genetics , Isochromosomes/genetics , Polymerase Chain Reaction/methods , Prenatal Diagnosis/methods , Adult , Chorionic Villi Sampling , Female , Humans , In Situ Hybridization, Fluorescence , Karyotyping , Pregnancy
12.
Ultrasound Obstet Gynecol ; 21(4): 329-33, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12704738

ABSTRACT

OBJECTIVE: Gastroschisis is associated with significant neonatal morbidity, and occasionally mortality. Previous studies looking at ways to prognosticate this condition by antenatal ultrasound have shown conflicting results. The aim of this study was to evaluate the usefulness of prenatal sonographic parameters to predict neonatal outcome of gastroschisis. METHODS: The charts, photographs, and videotapes of all fetuses with gastroschisis who were assessed during pregnancy at the Mater Mothers' Hospital, Brisbane over an 8.5-year period (Jan 1993-May 2001) were reviewed. Adverse neonatal outcome was defined as death, severe bowel complications (atresia, perforation, necrotic segments), need for multiple bowel operations, or a combination of these. Various sonographic parameters assessed included: gestation at first diagnosis, maximum bowel diameter, maximum bowel wall thickness, presence of other anomalies, evidence of growth restriction, and polyhydramnios. RESULTS: Forty-five patients met the entry criteria during the study period. Six neonates died, 12 had severe bowel complications, and 15 had a combination of the adverse outcomes. Polyhydramnios was most significantly associated with severe bowel complications, with a likelihood ratio of 11.7 (P = 0.001). Other ultrasound parameters were not significantly correlated with neonatal outcome. CONCLUSION: Most standard ultrasound parameters assessed antenatally in fetal gastroschisis were not significantly associated with adverse neonatal outcome, except for polyhydramnios, which was strongly predictive of severe bowel complications in the neonatal period. This information is important both for parents and for health professionals managing pregnancies with fetal gastroschisis.


Subject(s)
Gastroschisis/diagnostic imaging , Ultrasonography, Prenatal/methods , Adolescent , Adult , Female , Fetal Growth Retardation/diagnostic imaging , Gestational Age , Humans , Parity , Pregnancy , Pregnancy Outcome
13.
J Clin Microbiol ; 41(1): 472-4, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12517898

ABSTRACT

We present data on the prevalence of Candida species isolated from inpatients in three Singapore hospitals and from vaginal samples collected at community clinics. Strikingly, approximately 20% of the isolates from blood and vaginal samples were fluconazole-resistant species. By analyzing species-specific gene sequence signatures, we identified Candida dubliniensis from both groups of patients.


Subject(s)
Candida/isolation & purification , Candidiasis/epidemiology , Candida/classification , Candida/drug effects , Candida/genetics , Drug Resistance, Fungal , Humans , Microbial Sensitivity Tests , Polymerase Chain Reaction , Prevalence , Singapore/epidemiology
14.
Ultrasound Obstet Gynecol ; 21(1): 19-25, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12528156

ABSTRACT

OBJECTIVE: To assess the factors influencing the prenatal detection rate of structural congenital heart diseases (CHDs). METHODS: A retrospective study was conducted at a major obstetric hospital in Australia between 1 January 1996 and 30 June 1999. The medical records of all fetuses and infants born with CHD, except those with isolated patent ductus arteriosus or secundum atrial septal defect, were reviewed. Only pregnancies that had prenatal ultrasound scan assessments for morphological surveys were included. The following factors that may influence the detection rate were assessed: complexity of the lesions; experience of the sonographers (performance in tertiary versus non-tertiary institutions); presence of other structural or chromosomal anomalies; and maternal body mass index (BMI). RESULTS: The incidence of structural CHD in this series, excluding cases referred from other hospitals, was 7.0 per 1000 (179/25 529). Of the 179 pregnancies with CHD, 151 had prenatal ultrasound scans and were included in the study. The overall detection rate for CHDs in this series was 40.4%. The detection rate for isolated septal defects was poor (13.7%). The detection rates were significantly higher for complex lesions (54%), for lesions with concomitant septal defects (66.7%), and for lesions with abnormal four-chamber views (62.9%). The detection rate was also higher if the scan was performed in the tertiary institution, and if there were other chromosomal or structural anomalies. Maternal BMI did not affect the detection rate in the current series. Stepwise logistic regression analysis showed that three independent variables affecting the detection rate were complexity of the cardiac lesion, experience of the operator, and the detection of chromosomal anomalies. CONCLUSION: A high detection rate for major CHDs can be achieved in a screening setting but there is still room for improvement in scanning skills in the four-chamber view and great-artery analysis in both tertiary and local centers.


Subject(s)
Heart Defects, Congenital/diagnostic imaging , Ultrasonography, Prenatal/standards , Down Syndrome/diagnostic imaging , Female , Hospitalization , Humans , Pregnancy , Regression Analysis , Retrospective Studies , Sensitivity and Specificity , Trisomy
15.
J Telemed Telecare ; 9 Suppl 2: S12-4, 2003.
Article in English | MEDLINE | ID: mdl-14728749

ABSTRACT

Until recently, fetoscopic laser surgery to seal the placental anastomoses that cause severe twin-to-twin transfusion syndrome has been available in only a few centres worldwide. The technique typically takes a long time to learn. We have used a dedicated Internet Protocol (IP) connection for tele-education to assist the introduction of fetoscopic laser surgery to Australia. During the implementation of the international telemedicine link, there were multiple clinical and technical problems, which were eventually overcome. The quality of images and of video-sequences was comparable to that supported by an ISDN connection. Pictures of live surgery performed by an expert in Florida, USA, were transmitted and viewed by a novice team in Brisbane, Australia. The Australian team has performed 19 fetoscopic laser operations to date. Preliminary results are comparable to those from centres that have performed over 100 procedures.


Subject(s)
Education, Distance/methods , Education, Medical, Continuing/methods , Fetofetal Transfusion/surgery , Fetoscopy/methods , Internet , Telemedicine , Australia , Female , Florida , Humans , Laser Therapy/methods , Pregnancy , Telemedicine/standards
16.
J Telemed Telecare ; 8(2): 91-6, 2002.
Article in English | MEDLINE | ID: mdl-11972943

ABSTRACT

We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IP). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.


Subject(s)
Remote Consultation/standards , Ultrasonography, Prenatal/standards , Computer Communication Networks/standards , Female , Humans , Pregnancy , Queensland , Video Recording
17.
Ultrasound Obstet Gynecol ; 19(2): 171-6, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11876810

ABSTRACT

OBJECTIVES: To assess the detection rate of congenital fetal malformations and specific problems related to routine ultrasound screening in women with pre-existing diabetes. METHODS: A retrospective study was carried out to assess the performance of routine ultrasound screening in women with pre-existing diabetes (Types 1 and 2) within a tertiary institution. The incidence, type and risk factors for congenital fetal malformations were determined. The detection rate of fetal anomalies for diabetic women was compared with that for the low-risk population. Factors affecting these detection rates were evaluated. RESULTS: During the study period, 12 169 low-risk pregnant women and 130 women with pre-existing diabetes had routine ultrasound screening performed within the institution. A total of 10 major anomalies (7.7%) and three minor anomalies (2.3%) were present in the fetuses of the diabetic women. Central nervous system and cardiovascular system anomalies accounted for 60% of the major anomalies. Periconceptional hemoglobin A1c of more than 9% was associated with a high prevalence of major anomalies (143/1000). Women who had fetuses with major anomalies had a significantly higher incidence of obesity (78% vs. 37%; P < 0.05). Ultrasound examination of these diabetic pregnancies showed high incidences of suboptimal image quality (37%), incomplete examinations, and repeat examinations (17%). Compared to the 'low-risk' non-diabetic population from the same institution, the relative risk for a major congenital anomaly among the diabetic women was 5.9-fold higher (95% confidence interval, 2.9-11.9). The detection rate for major fetal anomalies was significantly lower for diabetic women (30% vs. 73%; P < 0.01), and the mean body mass index for the diabetic group was significantly higher (29 vs. 23 kg/m2; P < 0.001). CONCLUSION: The incidence of congenital anomalies is higher in diabetic pregnancies. Unfortunately, the detection rate for fetal anomalies by antenatal ultrasound scan was significantly worse than that for the low-risk population. This is likely to be related to the maternal body habitus and unsatisfactory examinations. Methods to overcome these difficulties are discussed.


Subject(s)
Congenital Abnormalities/diagnostic imaging , Fetal Diseases/diagnostic imaging , Mass Screening , Pregnancy in Diabetics/diagnostic imaging , Adult , Congenital Abnormalities/epidemiology , Diagnostic Tests, Routine , Female , Humans , Pregnancy , Ultrasonography, Prenatal
18.
Support Care Cancer ; 10(2): 139-45, 2002 Mar.
Article in English | MEDLINE | ID: mdl-11862503

ABSTRACT

A prospective longitudinal study was designed to assess the role of pretreatment proneness to nausea and vomiting (NV) in the development of postchemotherapy NV in a group of Chinese breast cancer patients receiving moderately highly emetogenic chemotherapy. Seventy-one chemotherapy-naive subjects participated in the study. Patients were assessed the day before chemotherapy with measurements of their anxiety level, depression, fatigue and proneness to NV, motion sickness, NV experienced in past pregnancies, history of labyrinthitis, expectation of developing NV and expectation of developing pain. Patients also completed daily assessments of frequency, duration and intensity of NV for the 7 days after chemotherapy. Regression analyses revealed that nonpharmacological factors explained part of the variance of NV, the most common predictors being a history of labyrinthitis, expectation of developing NV after chemotherapy, younger age, stage of disease, and state anxiety. The explanatory power of the models ranged from 6% to 23% of the variance of the independent variable. There were different explanatory models for acute and delayed NV. Results indicate that consideration of the role of nonpharmacological factors in the development of NV could lead to more effective management of NV induced by chemotherapy.


Subject(s)
Antineoplastic Agents/therapeutic use , Breast Neoplasms/complications , Breast Neoplasms/drug therapy , Nausea/chemically induced , Vomiting/chemically induced , Acute Disease , Adult , Age Factors , Antineoplastic Agents/adverse effects , Breast Neoplasms/epidemiology , Female , Hong Kong/epidemiology , Humans , Longitudinal Studies , Middle Aged , Predictive Value of Tests , Prospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome , Women's Health
19.
J Telemed Telecare ; 7 Suppl 2: 7-11, 2001.
Article in English | MEDLINE | ID: mdl-11747644

ABSTRACT

We have established a realtime fetal tele-ultrasound consultation service in Queensland, which has been integrated into our routine clinical practice. The service, which uses ISDN transmission at 384 kbit/s, allows patients in Townsville to be examined by subspecialists in Brisbane, 1500 km away. For the 90 tele-ultrasound consultations performed for the first 71 patients, 90% of the babies have been delivered, and outcome data have been received on all the pregnancies. All significant anomalies and diagnoses have been confirmed. The referring clinicians would have physically referred 24 of the 71 patients to Brisbane in the absence of telemedicine. A crude cost-benefit calculation suggests that the tele-ultrasound service resulted in a net saving of A$6340, and at the same time enabled almost four times the number of consultations to be carried out.


Subject(s)
Pregnancy Complications/diagnostic imaging , Prenatal Care/standards , Remote Consultation/standards , Ultrasonography, Prenatal/methods , Cost-Benefit Analysis , Female , Humans , Patient Satisfaction , Pregnancy , Prenatal Care/economics , Queensland , Remote Consultation/economics , Ultrasonography, Prenatal/economics
20.
J Telemed Telecare ; 7 Suppl 2: 88-90, 2001.
Article in English | MEDLINE | ID: mdl-11747673

ABSTRACT

If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320x240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.


Subject(s)
Remote Consultation/standards , Ultrasonography, Prenatal/standards , Female , Humans , Image Interpretation, Computer-Assisted/standards , Pregnancy , Queensland
SELECTION OF CITATIONS
SEARCH DETAIL
...