Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Med Res ; 24(1): 25, 2019 Jul 26.
Article in English | MEDLINE | ID: mdl-31349792

ABSTRACT

BACKGROUND: Cardioembolism in paroxysmal atrial fibrillation (PAF) is a preventable cause of transient ischaemic attack (TIA) or ischaemic stroke; however, due to its transient nature, a short-duration Holter monitor may miss a significant proportion of events. METHODS: We conducted an open-label randomised controlled trial of cardiac monitoring after a TIA or ischaemic stroke comparing a 14-day ECG monitoring patch (Zio® Patch, iRhythm Technologies) with short-duration Holter monitoring for the detection of PAF. The primary outcome was the detection of one or more episodes of ECG-documented PAF lasting at least 30 s within 90 days in each of the study arms. A budget impact analysis from the healthcare perspective was performed. RESULTS: From February 2016 through February 2017, 43 (76.8%) of the 56 patients assigned to the patch-based monitoring group and 47 (78.3%) of the 60 patients assigned to short-duration Holter monitoring group had successful monitor placement with 90 days of follow-up. Of the 26 protocol failures between the two groups, 23 (88.5%) were due to patient refusal for outpatient short-duration ECG monitor placement, whilst only 1 (3.8%) was due unsuccessful ZioPatch placement. The rate of detection of PAF at 90 days was 16.3% in the patch-based monitoring group (seven patients) compared to 2.1% in the short-duration Holter monitoring group (1 patient), with an odds ratio of 8.9 (95% CI 1.1-76.0; P = 0.026). An economic model demonstrated that implementation of the Zio Patch service would result in 10.8 more strokes avoided per year compared to current practice with Holter monitoring with an associated yearly saving in direct medical costs of £113,630, increasing to £162,491 over 5 years. CONCLUSIONS: Early, prolonged, patch-based monitoring after an index stroke or TIA is superior to short-duration Holter monitoring in the detection of PAF and likely cost-effective for preventing recurrent strokes. Trial registration http://www.isrctn.com. Unique identifier: ISRCTN 50253271. Registered 21 January 2016.


Subject(s)
Electrocardiography, Ambulatory , Heart/physiopathology , Stroke/diagnostic imaging , Aged , Atrial Fibrillation/diagnosis , Endpoint Determination , Female , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...