Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomech ; 168: 112124, 2024 May.
Article in English | MEDLINE | ID: mdl-38701696

ABSTRACT

Congenital arterial stenosis such as supravalvar aortic stenosis (SVAS) are highly prevalent in Williams syndrome (WS) and other arteriopathies pose a substantial health risk. Conventional tools for severity assessment, including clinical findings and pressure gradient estimations, often fall short due to their susceptibility to transient physiological changes and disease stage influences. Moreover, in the pediatric population, the severity of these and other congenital heart defects (CHDs) often restricts the applicability of invasive techniques for obtaining crucial physiological data. Conversely, evaluating CHDs and their progression requires a comprehensive understanding of intracardiac blood flow. Current imaging modalities, such as blood speckle imaging (BSI) and four-dimensional magnetic resonance imaging (4D MRI) face limitations in resolving flow data, especially in cases of elevated flow velocities. To address these challenges, we devised a computational framework employing zero-dimensional (0D) lumped parameter models coupled with patient-specific reconstructed geometries pre- and post-surgical intervention to execute computational fluid dynamic (CFD) simulations. This framework facilitates the analysis and visualization of intricate blood flow patterns, offering insights into geometry and flow dynamics alterations impacting cardiac function. In this study, we aim to assess the efficacy of surgical intervention in correcting an extreme aortic defect in a patient with WS, leading to reductions in wall shear stress (WSS), maximum velocity magnitude, pressure drop, and ultimately a decrease in cardiac workload.


Subject(s)
Hemodynamics , Models, Cardiovascular , Williams Syndrome , Humans , Williams Syndrome/physiopathology , Williams Syndrome/diagnostic imaging , Hemodynamics/physiology , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Aorta/physiopathology , Aorta/diagnostic imaging , Blood Flow Velocity/physiology , Male , Female , Computer Simulation
2.
J Magn Reson Imaging ; 42(6): 1765-76, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25914149

ABSTRACT

BACKGROUND: Cardiac MRI is routinely performed for quantification of shunt flow in patients with anomalous pulmonary veins, but can be technically-challenging to perform. Four-dimensional phase-contrast (4D-PC) MRI has potential to simplify this exam. We sought to determine whether 4D-PC may be a viable clinical alternative to conventional 2D phase-contrast MR imaging. METHODS: With institutional review board approval and HIPAA-compliance, we retrospectively identified all patients with anomalous pulmonary veins who underwent cardiac MRI at either 1.5 Tesla (T) or 3T with parallel-imaging compressed-sensing (PI-CS) 4D-PC between April, 2011 and October, 2013. A total of 15 exams were included (10 male, 5 female). Algorithms for interactive streamline visualization were developed and integrated into in-house software. Blood flow was measured at the valves, pulmonary arteries and veins, cavae, and any associated shunts. Pulmonary veins were mapped to their receiving atrial chamber with streamlines. The intraobserver, interobserver, internal consistency of flow measurements, and consistency with conventional MRI were then evaluated with Pearson correlation and Bland-Altman analysis. RESULTS: Triplicate measurements of blood flow from 4D-PC were highly consistent, particularly at the aortic and pulmonary valves (cv 2-3%). Flow measurements were reproducible by a second observer (ρ = 0.986-0.999). Direct measurements of shunt volume from anomalous veins and intracardiac shunts matched indirect estimates from the outflow valves (ρ = 0.966). Measurements of shunt fraction using 4D-PC using any approach were more consistent with ventricular volumetric displacements than conventional 2D-PC (ρ = 0.972-0.991 versus 0.929). CONCLUSION: Shunt flow may be reliably quantified with 4D-PC MRI, either indirectly or with detailed delineation of flow from multiple shunts. The 4D-PC may be a more accurate alternative to conventional MRI.


Subject(s)
Blood Flow Velocity , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Pulmonary Veins/abnormalities , Pulmonary Veins/physiopathology , Adolescent , Adult , Algorithms , Child , Child, Preschool , Humans , Infant , Observer Variation , Pulmonary Veins/pathology , Reproducibility of Results , Sensitivity and Specificity , User-Computer Interface , Young Adult
3.
Catheter Cardiovasc Interv ; 77(5): 680-91, 2011 Apr 01.
Article in English | MEDLINE | ID: mdl-21061250

ABSTRACT

OBJECTIVES: In this work, we examine the effects of stent-induced aortic stiffness on cardiac workload and blood pressure using computational fluid dynamic simulations. BACKGROUND: Treatment of aortic coarctation (CoA) consists of either open, surgical repair or angioplasty with or without stenting. Although stenting is a minimally invasive alternative to surgery, aortic stiffness increases in the stented section. Concern over this increased stiffness has long been argued to be detrimental to the overall vascular health of the patient. METHODS: MR imaging was performed on a 15-year-old female with CoA. A 3D model of the large thoracic arteries was created, and the heart and downstream vasculature were represented by lumped parameter models at the model inlet and outlets, respectively. A deformable wall assumption was used in conjunction with variable wall properties and tissue support, and 3D velocity, pressure, and wall dynamics were computed. The lumped parameter values and wall properties were tuned to match the mean flow and aortic deformation as measured by MRI. The CoA was then virtually removed from the model representing an end-to-end surgical correction. In a second model, the repaired section was prescribed to be nearly rigid, representing stenting. All other variables remained the same. RESULTS: When compared to surgery, stenting resulted in clinically negligible increases in cardiac work (0.4%) and no change in mean blood pressure. CONCLUSIONS: This pilot study suggests CoA stenting may not affect cardiac work to any significant degree as is commonly believed in the clinical community.


Subject(s)
Aorta/surgery , Aortic Coarctation/therapy , Endovascular Procedures/instrumentation , Models, Cardiovascular , Molecular Dynamics Simulation , Stents , Vascular Surgical Procedures , Ventricular Function , Adolescent , Adult , Aorta/physiopathology , Aortic Coarctation/physiopathology , Aortic Coarctation/surgery , Blood Flow Velocity , Blood Pressure , Compliance , Female , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Pilot Projects , Regional Blood Flow , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...