J Appl Physiol (1985) ; 117(9): 1037-48, 2014 Nov 01.
Article in English | MEDLINE | ID: mdl-25170067

ABSTRACT

Cerebral blood flow responses to transient blood pressure challenges are frequently attributed to cerebral autoregulation (CA), yet accumulating evidence indicates vascular properties like compliance are also influential. We hypothesized that middle cerebral blood velocity (MCAv) dynamics during or following a transient blood pressure perturbation can be accurately explained by the windkessel mechanism. Eighteen volunteers underwent blood pressure manipulations, including bilateral thigh-cuff deflation and sit-to-stand maneuvers under normocapnic and hypercapnic (5% CO2) conditions. Pressure-flow recordings were analyzed using a windkessel analysis approach that partitions the frequency-dependent resistance and compliance contributions to MCAv dynamics. The windkessel was typically able to explain more than 50% of the MCAv variance, as indicated by R(2) values for both the flow recovery and postrecovery phase. The most consistent predictors of MCAv dynamics under the control condition were the windkessel capacitive gain and high-frequency resistive gain. However, there were significant interindividual variations in the composition of windkessel predictors. Hypercapnia consistently reduced the capacitive gain and enhanced the low-frequency (0.04-0.20 Hz) resistive gain for both thigh-cuff deflation and sit-to-stand trials. These findings indicate that 1) MCAv dynamics during acute transient hypotension challenges are dominated by cerebrovascular windkessel properties independent of CA; 2) there is significant heterogeneity in windkessel properties between individuals; and 3) hemodynamic effects of hypercapnia during transient blood pressure challenges primarily reflect changes in windkessel properties rather than pure CA impairment.


Subject(s)
Blood Flow Velocity/physiology , Blood Pressure/physiology , Cerebrovascular Circulation/physiology , Hemodynamics/physiology , Middle Cerebral Artery/physiopathology , Female , Homeostasis/physiology , Humans , Hypercapnia/physiopathology , Male , Ultrasonography, Doppler, Transcranial , Young Adult
2.
Physiol Meas ; 33(3): 465-86, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22370141

ABSTRACT

Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure differences between the result obtained from the algorithm and the RS. 90% of the actual noise contaminated signals were correctly identified, and a sample-wise accuracy, sensitivity and specificity of 97.0%, 80.61% and 98.16%, respectively, were obtained from 100 pooled signals. The mean systolic and diastolic differences were 0.37 ± 3.31 and 3.10 ± 5.46 mmHg, respectively, when the artifact detection algorithm was utilized, with the algorithm correctly determined if the signal was clean enough to attempt an estimation of systolic or diastolic pressures in 93% of blood pressure measurements.


Subject(s)
Blood Pressure Determination/methods , Signal Processing, Computer-Assisted , Adult , Algorithms , Electrocardiography , Female , Humans , Male , Oscillometry , Reproducibility of Results