Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Diabetes Technol Ther ; 25(10): 677-688, 2023 10.
Article in English | MEDLINE | ID: mdl-37578778

ABSTRACT

Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Ketoacidosis , Hypoglycemia , Humans , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/drug therapy , Feasibility Studies , Hypoglycemia/chemically induced , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Insulin, Regular, Human/therapeutic use , Pilot Projects
2.
Crit Care Med ; 51(1): 136-140, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36519987

ABSTRACT

OBJECTIVES: To quantify the accuracy of and clinical events associated with a risk alert threshold for impending hypoglycemia during ICU admissions. DESIGN: Retrospective electronic health record review of clinical events occurring greater than or equal to 1 and less than or equal to 12 hours after the hypoglycemia risk alert threshold was met. SETTING: Adult ICU admissions from June 2020 through April 2021 at the University of Virginia Medical Center. PATIENTS: Three hundred forty-two critically ill adults that were 63.5% male with median age 60.8 years, median weight 79.1 kg, and median body mass index of 27.5 kg/m2. INTERVENTIONS: Real-world testing of our validated predictive model as a clinical decision support tool for ICU hypoglycemia. MEASUREMENTS AND MAIN RESULTS: We retrospectively reviewed 350 hypothetical alerts that met inclusion criteria for analysis. The alerts correctly predicted 48 cases of level 1 hypoglycemia that occurred greater than or equal to 1 and less than or equal to 12 hours after the alert threshold was met (positive predictive value = 13.7%). Twenty-one of these 48 cases (43.8%) involved level 2 hypoglycemia. Notably, three myocardial infarctions, one medical emergency team call, 19 deaths, and 20 arrhythmias occurred greater than or equal to 1 and less than or equal to 12 hours after an alert threshold was met. CONCLUSIONS: Alerts generated by a validated ICU hypoglycemia prediction model had a positive predictive value of 13.7% for real-world hypoglycemia events. This proof-of-concept result suggests that the predictive model offers clinical value, but further prospective testing is needed to confirm this.


Subject(s)
Clinical Deterioration , Decision Support Systems, Clinical , Hypoglycemia , Adult , Humans , Male , Middle Aged , Female , Retrospective Studies , Hypoglycemia/diagnosis , Intensive Care Units
4.
Medsurg Nurs ; 17(2): 93-8, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18517168

ABSTRACT

The American Heart Association (AH) guidelines for assuring accuracy in blood pressure measurement stress the importance of timing and positioning. Investigators in an ambulatory cardiology setting studied the relationship and their findings supported the recommendations. The AHA recommendations are reviewed along with results of a study in an ambulatory cardiology setting.


Subject(s)
Ambulatory Care/methods , Blood Pressure Determination/methods , Posture , Academic Medical Centers , Ambulatory Care/standards , Bias , Blood Pressure Determination/nursing , Blood Pressure Determination/standards , Clinical Nursing Research , Diastole , Evidence-Based Medicine , Female , Guideline Adherence , Humans , Hypertension/diagnosis , Interior Design and Furnishings , Male , Mid-Atlantic Region , Nursing Assessment , Nursing Evaluation Research , Practice Guidelines as Topic , Systole , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...