Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 285
Filter
1.
J Am Coll Radiol ; 21(6S): S65-S78, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38823956

ABSTRACT

Chronic hand and wrist pain is a common presenting complaint. The intricate anatomy results in a variety of pain generators-multiple bones, articular cartilage, intrinsic ligaments, triangular fibrocartilage complex, joint capsules and synovium, tendons and tendon sheaths, muscles, and nerves-in a compact space. The need for imaging and the choice of the appropriate imaging modality are best determined by the patient's presentation, physical examination, and the clinician's working differential diagnosis. Radiography is usually appropriate as the initial imaging study in the evaluation of chronic hand or wrist pain. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Chronic Pain , Evidence-Based Medicine , Societies, Medical , Humans , Chronic Pain/diagnostic imaging , United States , Hand/diagnostic imaging , Diagnosis, Differential , Arthralgia/diagnostic imaging
2.
J Bone Joint Surg Am ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38723057

ABSTRACT

BACKGROUND: The radius of curvature (ROC) of the femoral condyle is a factor in potential cartilage incongruities following osteochondral allograft (OCA) transplantation. Accurate restoration of the chondral surface may be achievable by using "best-fit" donor-recipient matching based on linear femorotibial dimensions, such as the femoral condyle anterior-posterior length (APL), femoral condyle width (lateral-medial length, LML), femoral hemicondyle width (HCW), and tibial plateau width (TPW), particularly if they correlate well with the ROC. This study aimed to investigate the correlative relationship between femorotibial dimensions and the ROC. METHODS: Computed tomography (CT) scans from 49 patients (31 men 28 ± 10 years old and 18 women 27 ± 6 years old) were analyzed. Axial images were used for APL and LML measurements, while coronal images were used for HCW and TPW. True sagittal images of the medial femoral condyle (MFC) and lateral femoral condyle (LFC) were used to calculate their individual ROCs by determining the best-fit circles along the condylar surface. Linear regression models were used to determine the relationship between the femorotibial dimensions and ROC. Measurements were repeated for a randomly selected subset of the data, and intraclass correlation coefficients (ICCs) were calculated to investigate intra- and interobserver reliability. RESULTS: All femorotibial dimensions showed significant correlations with the MFC and LFC ROCs (p < 0.01). The ROC correlations with femorotibial dimensions were found to be in the following descending order: APL (R2 ≥ 0.83), LML (R2 ≥ 0.52), TPW (R2 ≥ 0.36), and HCW (R2 ≥ 0.27). The intra- and interobserver reliabilities for the APL (ICC > 0.98) and ROC (ICC > 0.94) were excellent. CONCLUSIONS: The ROC was strongly correlated with the APL of the MFC and LFC. Donor-recipient APL matching in OCA transplantation may provide a level of matching similar to that achievable by direct ROC measurements. CLINICAL RELEVANCE: Determining the most predictive femorotibial dimension for ROC restoration in the OCA matching process may improve clinical outcomes, particularly for patients with large osteochondral lesions.

3.
Front Neuroimaging ; 3: 1356713, 2024.
Article in English | MEDLINE | ID: mdl-38783990

ABSTRACT

Purpose: To test the ability of inversion-recovery ultrashort echo time (IR-UTE) MRI to directly detect demyelination in mice using a standard cuprizone mouse model. Methods: Non-aqueous myelin protons have ultrashort T2s and are "invisible" with conventional MRI sequences but can be detected with UTE sequences. The IR-UTE sequence uses an adiabatic inversion-recovery preparation to suppress the long T2 water signal so that the remaining signal is from the ultrashort T2 myelin component. In this study, eight 8-week-old C57BL/6 mice were fed cuprizone (n = 4) or control chow (n = 4) for 5 weeks and then imaged by 3D IR-UTE MRI. The differences in IR-UTE signal were compared in the major white matter tracts in the brain and correlated with the Luxol Fast Blue histochemical marker of myelin. Results: IR-UTE signal decreased in cuprizone-treated mice in white matter known to be sensitive to demyelination in this model, such as the corpus callosum, but not in white matter known to be resistant to demyelination, such as the internal capsule. These findings correlated with histochemical staining of myelin content. Conclusions: 3D IR-UTE MRI was sensitive to cuprizone-induced demyelination in the mouse brain, and is a promising noninvasive method for measuring brain myelin content.

4.
Ultrasound Med Biol ; 2024 May 08.
Article in English | MEDLINE | ID: mdl-38724329

ABSTRACT

OBJECTIVE: To compare the effectiveness of positive pressure (PP) and negative pressure (NP) for reducing gas inclusions in biological tissues in preparation for acoustic imaging. METHODS: Eighteen pieces of porcine liver in degassed saline were included in this study. For the PP group (n = 9 samples), a wristwatch waterproof tester was used to pressurize samples to 0.41 MPa (59 psi) for 10 min. For the NP group (n = 9 samples), a desiccator at -0.08 MPa (-12 psi) was used for 30 min. Backscatter coefficients (BSCs) were calculated over the central frequency range of the backscattered spectra and paired-samples t-tests were performed. RESULTS: Utilization of PP resulted in a decrease in BSC for all samples, indicating less gas post-PP (pre-PP -13.0 ± 4.3 dB [mean ± SD], post-PP -18.9 ± 5.0 dB, p = .001). Utilization of NP resulted in an increase in BSC for the majority of samples (pre-NP -14.6 ± 6.0 dB, post-NP -13.1 ± 5.3 dB, p = .177). CONCLUSION: Utilization of a simple PP chamber consistently resulted in a decrease in tissue gas, at lower pressures than previously reported. The vacuum method is ineffective, may result in a paradoxical increase in tissue gas, and may not be recommended for tissue degassing.

5.
Quant Imaging Med Surg ; 14(4): 3146-3156, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38617168

ABSTRACT

Background: Tendon and bone comprise a critical interrelating unit. Bone loss, including that seen with osteopenia (OPe) or osteoporosis (OPo), may be associated with a reduction in tendon quality, though this remains incompletely investigated. Clinical magnetic resonance imaging (MRI) sequences cannot directly detect signals from tendons because of the very short T2. Clinical MRI may detect high-graded abnormalities by changes in the adjacent structures like bone. However, ultrashort echo time MRI (UTE-MRI) can capture high signals from all tendons. To determine if the long T2 fraction, as measured by a dual-echo UTE-MRI sequence, is a sensitive quantitative technique to the age- and bone-loss-related changes of the lower leg tendons. Methods: This is a cross-sectional study conducted between January 2018 to February 2020 in the lower legs of 14 female patients with OPe [72±6 years old, body mass index (BMI) =25.8±6.2 kg/m2] and 31 female patients with OPo (73±6 years old, BMI=22.0±3.8 kg/m2), as well as 30 female subjects with normal bone (Normal, 35±18 years old, BMI =23.2±4.3 kg/m2), were imaged on a 3T clinical scanner using a dual-echo 3D Cones UTE sequence. We defined the apparent long T2 signal fraction (aFrac-LongT2) of tendons as the ratio between the signal at the second echo time (TE =2.2 ms) to the UTE signal. The average aFrac-LongT2 and the cross-sectional area were calculated for the anterior tibialis tendons (ATTs) and the posterior tibialis tendons (PTTs). The Kruskal-Wallis rank test was used to compare the differences in aFrac-LongT2 and the cross-sectional area of the tendons between the groups. Results: The aFrac-LongT2 of the ATTs and PTTs were significantly higher in the OPo group compared with the Normal group (22.2% and 34.8% in the ATT and PTT, respectively, P<0.01). The cross-sectional area in the ATTs was significantly higher for the OPo group than in the Normal group (Normal/OPo difference was 28.7, P<0.01). Such a difference for PTTs did not reach the significance level. Mean aFrac-LongT2 and cross-sectional area in the OPe group were higher than the Normal group and lower than the OPo group. However, the differences did not show statistical significance, likely due to the higher BMI in the OPe group. Conclusions: Dual-echo UTE-MRI is a rapid quantification technique, and aFrac-LongT2 values showed significant differences in tendons between Normal and OPo patients.

6.
Bone ; 184: 117096, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38631596

ABSTRACT

High-resolution magnetic resonance imaging (HR-MRI) has been increasingly used to assess the trabecular bone structure. High susceptibility at the marrow/bone interface may significantly reduce the marrow's apparent transverse relaxation time (T2*), overestimating trabecular bone thickness. Ultrashort echo time MRI (UTE-MRI) can minimize the signal loss caused by susceptibility-induced T2* shortening. However, UTE-MRI is sensitive to chemical shift artifacts, which manifest as spatial blurring and ringing artifacts partially due to non-Cartesian sampling. In this study, we proposed UTE-MRI at the resonance frequency of fat to minimize marrow-related chemical shift artifacts and the overestimation of trabecular thickness. Cubes of trabecular bone from six donors (75 ± 4 years old) were scanned using a 3 T clinical scanner at the resonance frequencies of fat and water, respectively, using 3D UTE sequences with five TEs (0.032, 1.1, 2.2, 3.3, and 4.4 ms) and a clinical 3D gradient echo (GRE) sequence at 0.2 × 0.2 × 0.4 mm3 voxel size. Trabecular bone thickness was measured in 30 regions of interest (ROIs) per sample. MRI results were compared with thicknesses obtained from micro-computed tomography (µCT) at 50 µm3 voxel size. Linear regression models were used to calculate the coefficient of determination between MRI- and µCT-based trabecular thickness. All MRI-based trabecular thicknesses showed significant correlations with µCT measurements. The correlations were higher (examined with paired Student's t-test, P < 0.01) for 3D UTE images performed at the fat frequency (R2 = 0.59-0.74, P < 0.01) than those at the water frequency (R2 = 0.18-0.52, P < 0.01) and clinical GRE images (R2 = 0.39-0.47, P < 0.01). Significantly reduced correlations were observed with longer TEs. This study highlighted the feasibility of UTE-MRI at the fat frequency for a more accurate assessment of trabecular bone thickness.


Subject(s)
Cancellous Bone , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Cancellous Bone/diagnostic imaging , Aged , Male , Female , Adipose Tissue/diagnostic imaging
7.
J Bone Miner Res ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38591788

ABSTRACT

Ultrashort echo time (UTE) MRI can quantify the major proton pool densities in cortical bone, including total (TWPD), bound (BWPD), and pore water (PWPD) proton densities, as well as the macromolecular proton density (MMPD), associated with the collagen content, which is calculated using macromolecular fraction (MMF) from UTE magnetization transfer (UTE-MT) modeling. This study aimed to investigate the differences in water and collagen contents in tibial cortical bone, between female osteopenia (OPe) patients, osteoporosis (OPo) patients, and young participants (Young). Being postmenopausal and above 55 years old were the inclusion criteria for OPe and OPo groups. The tibial shaft of fourteen OPe (72.5 ± 6.8 years old), thirty-one OPo (72.0 ± 6.4 years old), and thirty-one young subjects (28.0 ± 6.1 years old) were scanned using a knee coil on a clinical 3 T scanner. Basic UTE, inversion recovery UTE, and UTE-MT sequences were performed. Investigated biomarkers were compared between groups using Kruskal-Wallis test. Spearman's correlation coefficients were calculated between the total hip dual-energy x-ray absorptiometry (DXA) T-score and UTE-MRI results. MMF, BWPD, and MMPD were significantly lower in OPo patients than in the young group. Whereas T1, TWPD, and PWPD were significantly higher in OPo patients. The largest OPo/Young average percentage differences were found in MMF (41.9%), PWPD (103.5%), and MMPD (64.0%). PWPD was significantly higher (50.7%), while BWPD was significantly lower (16.4%) in OPe than the Young group on average. MMF was found to be significantly lower (27%) in OPo patients compared with OPe group. T1, MMF, TWPD, PWPD, and MMPD values significantly correlated with the total hip DXA T-scores (provided by the patients and only available for OPe and OPo patients). DXA T-score showed the highest correlations with PWPD (R = 0.55) and MMF (R = 0.56) values. TWPD, PWPD, and MMF estimated using the UTE-MRI sequences were recommended to evaluate individuals with OPe and OPo.


Ultrashort echo time (UTE) is an MRI technique that can quantify the water and collagen content of cortical bone. Water in the bone can be found residing in pores (pore water) or bound to the bone matrix (bound water). We investigated the differences in water and collagen contents of tibial cortical bone, between female osteopenia patients, osteoporosis patients, and young participants. Bound water and collagen contents were significantly lower in osteoporosis patients than in the young group. Whereas total water and pore water contents were significantly higher in osteoporosis patients. Pore water was significantly higher, while bound water was significantly lower in osteopenia than in the Young group. Collagen content was found to be significantly lower in osteoporosis patients compared with the osteopenia group. The estimated water and collagen contents were significantly correlated with the total hip bone densitometry measures in the patients.

8.
J Imaging Inform Med ; 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38548992

ABSTRACT

We proposed an end-to-end deep learning convolutional neural network (DCNN) for region-of-interest based multi-parameter quantification (RMQ-Net) to accelerate quantitative ultrashort echo time (UTE) MRI of the knee joint with automatic multi-tissue segmentation and relaxometry mapping. The study involved UTE-based T1 (UTE-T1) and Adiabatic T1ρ (UTE-AdiabT1ρ) mapping of the knee joint of 65 human subjects, including 20 normal controls, 29 with doubtful-minimal osteoarthritis (OA), and 16 with moderate-severe OA. Comparison studies were performed on UTE-T1 and UTE-AdiabT1ρ measurements using 100%, 43%, 26%, and 18% UTE MRI data as the inputs and the effects on the prediction quality of the RMQ-Net. The RMQ-net was modified and retrained accordingly with different combinations of inputs. Both ROI-based and voxel-based Pearson correlation analyses were performed. High Pearson correlation coefficients were achieved between the RMQ-Net predicted UTE-T1 and UTE-AdiabT1ρ results and the ground truth for segmented cartilage with acceleration factors ranging from 2.3 to 5.7. With an acceleration factor of 5.7, the Pearson r-value achieved 0.908 (ROI-based) and 0.945 (voxel-based) for UTE-T1, and 0.733 (ROI-based) and 0.895 (voxel-based) for UTE-AdiabT1ρ, correspondingly. The results demonstrated that RMQ-net can significantly accelerate quantitative UTE imaging with automated segmentation of articular cartilage in the knee joint.

9.
Quant Imaging Med Surg ; 14(2): 1673-1685, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38415151

ABSTRACT

Background: Myelin water imaging (MWI) is a myelin-specific technique, which has great potential for the assessment of demyelination and remyelination. This study develops a new MWI method, which employs a short repetition time adiabatic inversion recovery (STAIR) technique in combination with a commonly used fast spin echo (FSE) sequence and provides quantification of myelin water (MW) fractions. Method: Whole-brain MWI was performed using the short repetition time adiabatic inversion recovery prepared-fast spin echo (STAIR-FSE) technique on eight healthy volunteers (mean age: 38±14 years, four-males) and seven patients with multiple sclerosis (MS) (mean age: 53.7±8.7 years, two-males) on a 3T clinical magnetic resonance imaging scanner. To facilitate the quantification of apparent myelin water fraction (aMWF), a proton density-weighted FSE was also used during the scans to allow total water imaging. The aMWF measurements of MS lesions and normal-appearing white matter (NAWM) regions in MS patients were compared with those measured in normal white matter (NWM) regions in healthy volunteers. Both the analysis of variance (ANOVA) test and paired comparison were performed for the comparison. Results: The MW in the whole-brain was selectively imaged and quantified using the STAIR-FSE technique in all participants. MS lesions showed much lower signal intensities than NAWM in the STAIR-FSE images. ANOVA analysis revealed a significant difference in the aMWF measurements between the three groups. Moreover, the aMWF measurements in MS lesions were significantly lower than those in both NWM of healthy volunteers and NAWM of MS patients. Lower aMWF measurements in NAWM were also found in comparison with those in NWM. Conclusions: The STAIR-FSE technique is capable of measuring aMWF values for the indirect detection of myelin loss in MS, thus facilitating clinical translation of whole brain MWI and quantification, which show great potential for the detection and evaluation of changes in myelin in the brain of patients with MS for future larger cohort studies.

10.
Eur Radiol Exp ; 8(1): 21, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38316687

ABSTRACT

BACKGROUND: We investigated the relationship of two commonly used quantitative ultrasound (QUS) parameters, speed of sound (SoS) and attenuation coefficient (α), with water and macromolecular contents of bovine cortical bone strips as measured with ultrashort echo time (UTE) magnetic resonance imaging (MRI). METHODS: SoS and α were measured in 36 bovine cortical bone strips utilizing a single-element transducer with nominal 5 MHz center frequency based on the time of flight principles after accommodating for reflection losses. Specimens were then scanned using UTE MRI to measure total, bound, and pore water proton density (TWPD, BWPD, and PWPD) as well as macromolecular proton fraction and macromolecular transverse relaxation time (T2-MM). Specimens were also scanned using microcomputed tomography (µCT) at 9-µm isometric voxel size to measure bone mineral density (BMD), porosity, and pore size. The elastic modulus (E) of each specimen was measured using a 4-point bending test. RESULTS: α demonstrated significant positive Spearman correlations with E (R = 0.69) and BMD (R = 0.44) while showing significant negative correlations with porosity (R = -0.41), T2-MM (R = -0.47), TWPD (R = -0.68), BWPD (R = -0.67), and PWPD (R = -0.45). CONCLUSIONS: The negative correlation between α and T2-MM is likely indicating the relationship between QUS and collagen matrix organization. The higher correlations of α with BWPD than with PWPD may indicate that water organized in finer structure (bound to matrix) provides lower acoustic impedance than water in larger pores, which is yet to be investigated thoroughly. RELEVANCE STATEMENT: This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone, including the collagenous matrix and water. Investigating the full potential of QUS and its validation facilitates a more affordable and accessible tool for bone health monitoring in clinics. KEY POINTS: • Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone.


Subject(s)
Bone and Bones , Protons , Animals , Cattle , X-Ray Microtomography , Bone and Bones/diagnostic imaging , Cortical Bone/diagnostic imaging , Water
11.
Semin Musculoskelet Radiol ; 28(1): 62-77, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38330971

ABSTRACT

Magnetic resonance imaging (MRI) is increasingly used to evaluate the microstructural and compositional properties of bone. MRI-based biomarkers can characterize all major compartments of bone: organic, water, fat, and mineral components. However, with a short apparent spin-spin relaxation time (T2*), bone is invisible to conventional MRI sequences that use long echo times. To address this shortcoming, ultrashort echo time MRI sequences have been developed to provide direct imaging of bone and establish a set of MRI-based biomarkers sensitive to the structural and compositional changes of bone. This review article describes the MRI-based bone biomarkers representing total water, pore water, bound water, fat fraction, macromolecular fraction in the organic matrix, and surrogates for mineral density. MRI-based morphological bone imaging techniques are also briefly described.


Subject(s)
Bone and Bones , Magnetic Resonance Imaging , Humans , Bone and Bones/diagnostic imaging , Magnetic Resonance Imaging/methods , Water/chemistry , Minerals
12.
Skeletal Radiol ; 53(2): 209-244, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37566148

ABSTRACT

OBJECTIVE: Direct magnetic resonance arthrography (dMRA) is often considered the most accurate imaging modality for the evaluation of intra-articular structures, but utilization and performance vary widely without consensus. The purpose of this white paper is to develop consensus recommendations on behalf of the Society of Skeletal Radiology (SSR) based on published literature and expert opinion. MATERIALS AND METHODS: The Standards and Guidelines Committee of the SSR identified guidelines for utilization and performance of dMRA as an important topic for study and invited all SSR members with expertise and interest to volunteer for the white paper panel. This panel was tasked with determining an outline, reviewing the relevant literature, preparing a written document summarizing the issues and controversies, and providing recommendations. RESULTS: Twelve SSR members with expertise in dMRA formed the ad hoc white paper authorship committee. The published literature on dMRA was reviewed and summarized, focusing on clinical indications, technical considerations, safety, imaging protocols, complications, controversies, and gaps in knowledge. Recommendations for the utilization and performance of dMRA in the shoulder, elbow, wrist, hip, knee, and ankle/foot regions were developed in group consensus. CONCLUSION: Although direct MR arthrography has been previously used for a wide variety of clinical indications, the authorship panel recommends more selective application of this minimally invasive procedure. At present, direct MR arthrography remains an important procedure in the armamentarium of the musculoskeletal radiologist and is especially valuable when conventional MRI is indeterminant or results are discrepant with clinical evaluation.


Subject(s)
Arthrography , Magnetic Resonance Imaging , Humans , Arthrography/methods , Radiography , Magnetic Resonance Imaging/methods , Shoulder/diagnostic imaging , Wrist
13.
Skeletal Radiol ; 53(5): 881-890, 2024 May.
Article in English | MEDLINE | ID: mdl-37935923

ABSTRACT

PURPOSE: To investigate the feasibility and application of a novel imaging technique, a three-dimensional dual adiabatic inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence, for high contrast assessment of cartilaginous endplate (CEP) imaging with head-to-head comparisons between other UTE imaging techniques. METHOD: The DIR-UTE sequence employs two narrow-band adiabatic full passage (AFP) pulses to suppress signals from long T2 water (e.g., nucleus pulposus (NP)) and bone marrow fat (BMF) independently, followed by multispoke UTE acquisition to detect signals from the CEP with short T2 relaxation times. The DIR-UTE sequence, in addition to three other UTE sequences namely, an IR-prepared and fat-saturated UTE (IR-FS-UTE), a T1-weighted and fat-saturated UTE sequence (T1w-FS-UTE), and a fat-saturated UTE (FS-UTE) was used for MR imaging on a 3 T scanner to image six asymptomatic volunteers, six patients with low back pain, as well as a human cadaveric specimen. The contrast-to-noise ratio of the CEP relative to the adjacent structures-specifically the NP and BMF-was then compared from the acquired images across the different UTE sequences. RESULTS: For asymptomatic volunteers, the DIR-UTE sequence showed significantly higher contrast-to-noise ratio values between the CEP and BMF (CNRCEP-BMF) (19.9 ± 3.0) and between the CEP and NP (CNRCEP-NP) (23.1 ± 1.7) compared to IR-FS-UTE (CNRCEP-BMF: 17.3 ± 1.2 and CNRCEP-NP: 19.1 ± 1.8), T1w-FS-UTE (CNRCEP-BMF: 9.0 ± 2.7 and CNRCEP-NP: 10.4 ± 3.5), and FS-UTE (CNRCEP-BMF: 7.7 ± 2.2 and CNRCEP-NP: 5.8 ± 2.4) for asymptomatic volunteers (all P-values < 0.001). For the spine sample and patients with low back pain, the DIR-UTE technique detected abnormalities such as irregularities and focal defects in the CEP regions. CONCLUSION: The 3D DIR-UTE sequence is able to provide high-contrast volumetric CEP imaging for human spines on a clinical 3 T scanner.


Subject(s)
Low Back Pain , Humans , Bone and Bones , Magnetic Resonance Imaging/methods , Cartilage , Phantoms, Imaging , Imaging, Three-Dimensional/methods
14.
NMR Biomed ; 37(2): e5058, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37828713

ABSTRACT

Muscle degeneration following rotator cuff tendon tearing is characterized by fatty infiltration and fibrosis. While tools exist for the characterization of fat, the ability to noninvasively assess muscle fibrosis is limited. The purpose of this study was to evaluate the capability of quantitative ultrashort echo time T1 (UTE-T1) and UTE magnetization transfer (UTE-MT) mapping with and without fat suppression (FS) for the differentiation of injured and control rotator cuff muscles and for the detection of fibrosis. A rat model of chronic massive rotator cuff tearing (n = 12) was used with tenotomy of the right supraspinatus and infraspinatus tendons and silicone implants to prevent healing. Imaging was performed on a 3-T scanner, and UTE-T1 mapping with and without FS and UTE-MT with and without FS for macromolecular fraction (MMF) mapping was performed. At 20 weeks postinjury, T1 and MMF were measured in the supraspinatus and infraspinatus muscles of the injured and contralateral, internal control sides. Histology was performed and connective tissue fraction (CTF) was measured, defined as the area of collagen-rich extracellular matrix divided by the total muscle area. Paired t-tests and correlation analyses were performed. Significant differences between injured and control sides were found for CTF in the supraspinatus (mean ± SD, 14.5% ± 3.9% vs. 11.3% ± 3.7%, p = 0.01) and infraspinatus (17.0% ± 5.4% vs. 12.5% ± 4.6%, p < 0.01) muscles, as well as for MMF using UTE-MT FS in the supraspinatus (9.7% ± 0.3% vs. 9.5% ± 0.2%, p = 0.04) and infraspinatus (10.9% ± 0.8% vs. 10.1% ± 0.5%, p < 0.01) muscles. No significant differences between sides were evident for T1 without or with FS or for MMF using UTE-MT. Only MMF using UTE-MT FS was significantly correlated with CTF for both supraspinatus (r = 0.46, p = 0.03) and infraspinatus (r = 0.51, p = 0.01) muscles. Fibrosis occurs in rotator cuff muscle degeneration, and the UTE-MT FS technique may be helpful to evaluate the fibrosis component, independent from the fatty infiltration process.


Subject(s)
Rotator Cuff , Tendons , Animals , Rats , Rotator Cuff/diagnostic imaging , Rotator Cuff/pathology , Muscular Atrophy , Magnetic Resonance Imaging/methods , Adipose Tissue/pathology
16.
Magn Reson Med ; 91(3): 896-910, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37755319

ABSTRACT

PURPOSE: To develop a 3D phase modulated UTE adiabatic T1ρ (PM-UTE-AdiabT1ρ ) sequence for whole knee joint mapping on a clinical 3 T scanner. METHODS: This new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for spin locking, (3) a phase modulation scheme (i.e., RF cycling pair), (4) a fat saturation module, (5) a variable flip angle scheme, and (6) a 3D UTE Cones sequence for data acquisition. A simple exponential fitting was used for T1ρ quantification. Phantom studies were performed to investigate PM-UTE-AdiabT1ρ 's sensitivity to compositional changes and reproducibility as well as its correlation with continuous wave-T1ρ measurement. The PM-UTE-AdiabT1ρ technique was then applied to five ex vivo and five in vivo normal knees to measure T1ρ values of femoral cartilage, meniscus, posterior cruciate ligament, anterior cruciate ligament, patellar tendon, and muscle. RESULTS: The phantom study demonstrated PM-UTE-AdiabT1ρ 's high sensitivity to compositional changes, its high reproducibility, and its strong linear correlation with continuous wave-T1ρ measurement. The ex vivo and in vivo knee studies demonstrated average T1ρ values of 105.6 ± 8.4 and 77.9 ± 3.9 ms for the femoral cartilage, 39.2 ± 5.1 and 30.1 ± 2.2 ms for the meniscus, 51.6 ± 5.3 and 29.2 ± 2.4 ms for the posterior cruciate ligament, 79.0 ± 9.3 and 52.0 ± 3.1 ms for the anterior cruciate ligament, 19.8 ± 4.5 and 17.0 ± 1.8 ms for the patellar tendon, and 91.1 ± 8.8 and 57.6 ± 2.8 ms for the muscle, respectively. CONCLUSION: The 3D PM-UTE-AdiabT1ρ sequence allows volumetric T1ρ assessment for both short and long T2 tissues in the knee joint on a clinical 3 T scanner.


Subject(s)
Meniscus , Patellar Ligament , Reproducibility of Results , Knee Joint/diagnostic imaging , Anterior Cruciate Ligament/diagnostic imaging , Magnetic Resonance Imaging/methods
17.
Ultrason Imaging ; 46(1): 56-70, 2024 01.
Article in English | MEDLINE | ID: mdl-37981826

ABSTRACT

This study evaluated the repeatability and reproducibility of using high-frequency quantitative ultrasound (QUS) measurement of backscatter coefficient (BSC), grayscale analysis, and gray-level co-occurrence matrix (GLCM) textural analysis, to characterize human rotator cuff muscles. The effects of varying scanner settings across two different operators and two US systems were investigated in a healthy volunteer with normal rotator cuff muscles and a patient with chronic massive rotator cuff injury and substantial muscle degeneration. The results suggest that BSC is a promising method for assessing rotator cuff muscles in both control and pathological subjects, even when operators were free to adjust system settings (depth, level of focus, and time-gain compensation). Measurements were repeatable and reproducible across the different operators and ultrasound imaging platforms. In contrast, grayscale and GLCM analyses were found to be less reliable in this setting, with significant measurement variability. Overall, the repeatability and reproducibility measurements of BSC indicate its potential as a diagnostic tool for rotator cuff muscle evaluation.


Subject(s)
Adipose Tissue , Rotator Cuff , Humans , Rotator Cuff/diagnostic imaging , Rotator Cuff/pathology , Reproducibility of Results , Adipose Tissue/diagnostic imaging , Magnetic Resonance Imaging/methods , Ultrasonography
18.
NMR Biomed ; 37(1): e5040, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37740595

ABSTRACT

The purpose of this study is to investigate the use of ultrashort echo time (UTE) magnetic resonance imaging (MRI) techniques (T1 and magnetization transfer [MT] modeling) for imaging of the Achilles tendons and entheses in patients with psoriatic arthritis (PsA) compared with asymptomatic volunteers. The heels of twenty-six PsA patients (age 59 ± 15 years, 41% female) and twenty-seven asymptomatic volunteers (age 33 ± 11 years, 47% female) were scanned in the sagittal plane with UTE-T1 and UTE-MT modeling sequences on a 3-T clinical scanner. UTE-T1 and macromolecular proton fraction (MMF; the main outcome of MT modeling) were calculated in the tensile portions of the Achilles tendon and at the enthesis (close to the calcaneus bone). Mann-Whitney-U tests were used to examine statistically significant differences between the two cohorts. UTE-T1 in the entheses was significantly higher for the PsA group compared with the asymptomatic group (967 ± 145 vs. 872 ± 133 ms, p < 0.01). UTE-T1 in the tendons was also significantly higher for the PsA group (950 ± 145 vs. 850 ± 138 ms, p < 0.01). MMF in the entheses was significantly lower in the PsA group compared with the asymptomatic group (15% ± 3% vs. 18% ± 3%, p < 0.01). MMF in the tendons was also significantly lower in the PsA group compared with the asymptomatic group (17% ± 4% vs. 20% ± 5%, p < 0.01). Percentage differences in MMF between the asymptomatic and PsA groups (-16.6% and -15.0% for the enthesis and tendon, respectively) were higher than the T1 differences (10.8% and 11.7% for the enthesis and tendon, respectively). The results suggest higher T1 and lower MMF in the Achilles tendons and entheses in PsA patients compared with the asymptomatic group. This study highlights the potential of UTE-T1 and UTE-MT modeling for quantitative evaluation of entheses and tendons in PsA patients.


Subject(s)
Achilles Tendon , Arthritis, Psoriatic , Humans , Female , Adult , Middle Aged , Aged , Young Adult , Male , Achilles Tendon/diagnostic imaging , Arthritis, Psoriatic/diagnostic imaging , Arthritis, Psoriatic/pathology , Magnetic Resonance Imaging/methods , Protons
19.
Mil Med ; 188(Suppl 6): 590-597, 2023 11 08.
Article in English | MEDLINE | ID: mdl-37948284

ABSTRACT

INTRODUCTION: Foot and ankle fractures are the most common military health problem. Automated diagnosis can save time and personnel. It is crucial to distinguish fractures not only from normal healthy cases, but also robust against the presence of other orthopedic pathologies. Artificial intelligence (AI) deep learning has been shown to be promising. Previously, we have developed HAMIL-Net to automatically detect orthopedic injuries for upper extremity injuries. In this research, we investigated the performance of HAMIL-Net for detecting foot and ankle fractures in the presence of other abnormalities. MATERIALS AND METHODS: HAMIL-Net is a novel deep neural network consisting of a hierarchical attention layer followed by a multiple-instance learning layer. The design allowed it to deal with imaging studies with multiple views. We used 148K musculoskeletal imaging studies for 51K Veterans at VA San Diego in the past 20 years to create datasets for this research. We annotated each study by a semi-automated pipeline leveraging radiology reports written by board-certified radiologists and extracting findings with a natural language processing tool and manually validated the annotations. RESULTS: HAMIL-Net can be trained with study-level, multiple-view examples, and detect foot and ankle fractures with a 0.87 area under the receiver operational curve, but the performance dropped when tested by cases including other abnormalities. By integrating a fracture specialized model with one that detecting a broad range of abnormalities, HAMIL-Net's accuracy of detecting any abnormality improved from 0.53 to 0.77 and F-score from 0.46 to 0.86. We also reported HAMIL-Net's performance under different study types including for young (age 18-35) patients. CONCLUSIONS: Automated fracture detection is promising but to be deployed in clinical use, presence of other abnormalities must be considered to deliver its full benefit. Our results with HAMIL-Net showed that considering other abnormalities improved fracture detection and allowed for incidental findings of other musculoskeletal abnormalities pertinent or superimposed on fractures.


Subject(s)
Ankle Fractures , Artificial Intelligence , Humans , Adolescent , Young Adult , Adult , Neural Networks, Computer , Retrospective Studies
20.
Sci Rep ; 13(1): 20228, 2023 11 18.
Article in English | MEDLINE | ID: mdl-37980432

ABSTRACT

In this study, we evaluated the utility of using high-frequency ultrasound to non-invasively track the degenerative process in a rat model of peripheral nerve injury. Primary analyses explored spatial and temporal changes in quantitative backscatter coefficient (BSC) spectrum-based outcomes and B-mode textural outcomes, using gray level co-occurrence matrices (GLCMs), during the progressive transition from acute to chronic injury. As secondary analyses, correlations among GLCM and BSC spectrum-based parameters were evaluated, and immunohistochemistry were used to suggest a structural basis for ultrasound outcomes. Both mean BSC spectrum-based and mean GLCM-based measures exhibited significant spatial differences across presurgical and 1-month/2-month time points, distal stumps enclosed proximity to the injury site being particularly affected. The two sets of parameters sensitively detected peripheral nerve degeneration at 1-month and 2-month post-injury, with area under the receiver operating charactersitic curve > 0.8 for most parameters. The results also indicated that the many BSC spectrum-based and GLCM-based parameters significantly correlate with each other, and suggested a common structural basis for a diverse set of quantitative ultrasound parameters. The findings of this study suggest that BSC spectrum-based and GLCM-based analysis are promising non-invasive techniques for diagnosing peripheral nerve degeneration.


Subject(s)
Nerve Tissue , Peripheral Nerve Injuries , Rats , Animals , Sciatic Nerve/diagnostic imaging , Ultrasonography/methods , Peripheral Nerve Injuries/diagnostic imaging , Nerve Degeneration
SELECTION OF CITATIONS
SEARCH DETAIL
...