Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Adv Mater ; : e2400091, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38573312

ABSTRACT

Crystallographic characteristics, including grain boundaries and crystallographic orientation of each grain, are crucial in defining the properties of two-dimensional materials (2DMs). To date, local microstructure analysis of 2DMs, which requires destructive and complex processes, is primarily used to identify unknown 2DM specimens, hindering the subsequent use of characterized samples. Here, a nondestructive large-area 2D crystallographic analytical method through sticky-note-like van der Waals (vdW) assembling-disassembling is presented. By the vdW assembling of veiled polycrystalline graphene (PCG) with a single-atom-thick single-crystalline graphene filter (SCG-filter), detailed crystallographic information of each grain in PCGs is visualized through a 2D Raman signal scan, which relies on the interlayer twist angle. The scanned PCGs are seamlessly separated from the SCG-filter using vdW disassembling, preserving their original condition. The remaining SCG-filter is then reused for additional crystallographic scans of other PCGs. It is believed that the methods can pave the way for advances in the crystallographic analysis of single-atom-thick materials, offering huge implications for the applications of 2DMs.

2.
Proc (Bayl Univ Med Cent) ; 37(2): 205-209, 2024.
Article in English | MEDLINE | ID: mdl-38343487

ABSTRACT

Background: Conduction abnormality requiring the implantation of a permanent pacemaker (PPM) is a well-known and clinically important complication of transcatheter aortic valve replacement (TAVR). However, PPM implantation may result in lead-associated tricuspid valve regurgitation (TR). This study sought to determine the incidence and progression of TR following PPM implantation after TAVR. Methods: This was a retrospective review of all echocardiograms of patients who underwent PPM following TAVR at the Baylor Scott & White hospitals from 2012 to 2021. The primary endpoint was TR progression at 30 days and 1 year. A subanalysis comparing the change in TR progression between small and large TAVR devices was also conducted. Secondary outcomes included all-cause death at 30 days and 1 year. Results: Out of the 2744 patients who underwent TAVR between April 2012 and August 2021, 177 patients (6.5%) subsequently received a new PPM. There was a statistically significant progression of TR at 1-year follow-up (McNemar's P value = 0.02). TR progression rates were comparable between the small and large valve groups at 1-year follow-up (4% vs 11%, P = 0.09, respectively). Conclusion: In this single healthcare system study, we demonstrated a significant progression of TR in patients with PPM post TAVR at 1 year.

3.
Small ; : e2307276, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38196162

ABSTRACT

Graphdiyne (GDY) has garnered significant attention as a cutting-edge 2D material owing to its distinctive electronic, optoelectronic, and mechanical properties, including high mobility, direct bandgap, and remarkable flexibility. One of the key challenges hindering the implementation of this material in flexible applications is its large area and uniform synthesis. The facile growth of centimeter-scale bilayer hydrogen substituted graphdiyne (Bi-HsGDY) on germanium (Ge) substrate is achieved using a low-temperature chemical vapor deposition (CVD) method. This material's field effect transistors (FET) showcase a high carrier mobility of 52.6 cm2  V-1  s-1 and an exceptionally low contact resistance of 10 Ω µm. By transferring the as-grown Bi-HsGDY onto a flexible substrate, a long-distance piezoresistive strain sensor is demonstrated, which exhibits a remarkable gauge factor of 43.34 with a fast response time of ≈275 ms. As a proof of concept, communication by means of Morse code is implemented using a Bi-HsGDY strain sensor. It is believed that these results are anticipated to open new horizons in realizing Bi-HsGDY for innovative flexible device applications.

4.
J Echocardiogr ; 21(1): 33-39, 2023 03.
Article in English | MEDLINE | ID: mdl-35974215

ABSTRACT

PURPOSE: There is lack of validated methods for quantifying the size of pleural effusion from standard transthoracic (TTE) windows. The purpose of this study is to determine whether pleural effusion (Peff) measured from routine two-dimensional (2D) TTE views correlate with chest radiograph (CXR). MATERIALS AND METHODS: We retrospectively identified all inpatients who underwent a TTE and CXR within 2 days in a large tertiary care center. Peff was measured on TTE from parasternal long axis (PLAX), apical four-chamber (A4C), and subcostal views and on CXR. Logistic regression models were used determine optimal cut points to predict moderate or greater Peff. RESULTS: In 200 patients (mean age 69.3 ± 14.3 years, 49.5% female), we found statistically significant associations between Peff size assessed by all TTE views and CXR, with weak to moderate correlation (PLAX length: 0.21 (95% CI [0.05, 0.35]); PLAX depth: 0.21 (95% CI [0.05, 0.35]); A4C left: 0.31 (95% CI [0.13, 0.46]); A4C right: 0.39 (95% CI [0.17, 0.57]); subcostal: 0.38 (95% CI [0.07, 0.61]). The best TTE thresholds for predicting moderate or greater left-sided Peff on CXR was PLAX length left > = 8.6 cm (sensitivity 78%, specificity 54%, PPV 26%, and NPV 92%). The best TTE thresholds for predicting moderate or greater right-sided Peff on CXR was A4C right > = 2.6 cm (sensitivity 87%, specificity 60%, PPV 37%, and NPV 94%). CONCLUSIONS: We identified statistically significant associations with Peff size measured on TTE and CXR. The predictive ability of TTE to identify moderate or large pleural effusion is limited.


Subject(s)
Echocardiography , Pleural Effusion , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Retrospective Studies , Echocardiography/methods , Reproducibility of Results
5.
Circ Heart Fail ; 15(8): e009018, 2022 08.
Article in English | MEDLINE | ID: mdl-35904022

ABSTRACT

BACKGROUND: Clinical utility of cardiac biomarker testing during pregnancy in women with preexisting cardiac disease is not well known. We studied the levels and temporal trends of NT-proBNP (N-terminal pro-B-type natriuretic peptide) and hs-cTnI (high-sensitivity cardiac troponin I) throughout pregnancy in women with preexisting cardiac disease and sought to assess the association between NT-proBNP and hs-cTnI and pregnancy outcomes. METHODS: Three hundred seven pregnant women with preexisting cardiac disease were prospectively recruited. Mixed-effects linear regression analysis was used to compare the NT-proBNP and hs-cTnI levels between time periods and subgroups. Logistic regression analysis adjusted for maternal age and CARPREG II (Cardiac Disease in Pregnancy) risk score assessed the association between NT-proBNP levels and adverse events. RESULTS: Geometric mean NT-proBNP (95% CI) was stable through pregnancy with a transient significant increase with labor and delivery (101.4 pg/mL [87.1-118.1], 90.2 pg/mL [78.5-103.6], 153.6 pg/mL [126.8-186.1], and 112.2 pg/mL [94.2-133.7] for first/second trimester, third trimester, labor/delivery and postpartum, respectively). We observed a statistically significant difference in the NT-proBNP between women with preserved versus decreased systemic ventricular function, structurally normal versus abnormal heart, modified World Health Organization class 1, 2 versus modified World Health Organization class 3, 4 and no congenital heart disease versus congenital heart disease. Compared to those without events, median (interquartile range) NT-proBNP levels were significantly higher in those who had heart failure (204 pg/mL [51-450] versus 55 pg/mL [31-97]; P=0.001) and preeclampsia (98 pg/mL [40-319] versus 55 pg/mL [31-99]; P=0.027). NT-proBNP, adjusted for age and CARPREG II risk score, was significantly associated with combined heart failure and preeclampsia (adjusted odds ratio, 2.14 [95% CI, 1.48-3.10] per log NT-proBNP increase; P<0.001). NT-proBNP <200 pg/mL had a specificity of 91% and negative predictive value of 95% in predicting combined heart failure and preeclampsia. CONCLUSIONS: NT-proBNP remains steady over the course of pregnancy with a transient increase during labor and delivery with higher levels in subgroups of stable cardiac patients. NT-proBNP level of 200 pg/mL can be used in the diagnosis of heart failure/preeclampsia in the pregnant cardiac population.


Subject(s)
Cardiovascular Diseases , Heart Defects, Congenital , Heart Failure , Pre-Eclampsia , Biomarkers , Female , Humans , Natriuretic Peptide, Brain , Peptide Fragments , Pregnancy , Troponin I
6.
Article in English | MEDLINE | ID: mdl-34966961

ABSTRACT

The diagnostic accuracy of the cardiothoracic ratio on chest X-ray to detect left ventricular (LV) enlargement has not been well defined despite its traditional association with cardiomegaly. We aimed to determine whether the cardiothoracic ratio can accurately predict LV enlargement based on indexed linear measurements of the LV on transthoracic echocardiography (TTE). We included consecutive patients who had a TTE and a posteroanterior chest X-ray performed within 90 days of each other at a tertiary care center. LV size was determined by measuring the LV end-diastolic dimension (LVEDD) and LV end-diastolic dimension indexed (LVEDDI) to body surface area. The cardiothoracic ratio was calculated by dividing the maximum transverse diameter of the cardiac silhouette by the maximum transverse diameter of the right and left lung boundaries. 173 patients were included in the study (mean age 68 ± 15 years, 49.1% female). Mean cardiothoracic ratio was 0.56 ± 0.09, and the mean LVEDD and indexed LVEDDI were of 47 ± 8.6 mm and dimension of 27 ± 4.5 mm/m2 respectively. There was no significant correlation between the cardiothoracic ratio measured on chest X-ray and either the LVEDD or LVEDDI measured on TTE (r = 0.011, p = 0.879; r = 0.122, p = 0.111). The ability of the cardiothoracic ratio to predict LV enlargement (defined as LVEDDI > 30 mm/m2) was not statistically significant. The cardiothoracic ratio on chest X-ray is not a predictor of LV enlargement based on indexed linear measurements of the LV by TTE.

7.
Echocardiography ; 38(10): 1754-1761, 2021 10.
Article in English | MEDLINE | ID: mdl-34672021

ABSTRACT

BACKGROUND: The aim of our study was to characterize echocardiographic changes during pregnancy in women with known LVOT obstruction or AS compared to the healthy pregnancy controls, and to assess the relationship with pregnancy outcomes. METHODS: We retrospectively studied 34 pregnant patients with congenital LVOT obstruction or AS with healthy age-matched pregnant controls. Patients with other significant valvular lesions, structural heart disease (LVEF < 40%), or prior valve surgery were excluded. All LVOTO/AS patients underwent a minimum of two consecutive echocardiograms between 1 year pre-conception and 1 year postpartum, with at least two studies during the pregnancy. Comprehensive echocardiographic evaluation was performed including speckle-tracking LV global longitudinal strain. RESULTS: A total of 83 echocardiograms from the study group and 34 echocardiograms from the control group were evaluated. Over the range of LVOTO/AS, a significantly greater increase in the AV gradients and LV and LA volumes were observed as compared with the controls. In the sub-group of LVOTO/AS pregnant women with ≥ moderate (n = 8) versus < moderate LVOTO/AS (n = 26), averaged 2nd /3rd trimester LVEF was lower (51 ± 12)% versus (58 ± 4)%, (p = 0.02) and GLS was lower (-19.5 ± 2.8) versus (21.2 ± 2.4), (p = 0.06). Pregnancy was well tolerated despite these changes. CONCLUSION: Among pregnant women with even milder forms of LVOTO/AS, increases in cardiac volumes and AV gradients can be expected over the course of pregnancy. Significant decreases in LV function and mechanics were only observed in women with moderate or greater LVOTO/AS, although still remained in normal range.


Subject(s)
Aortic Valve Stenosis , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography , Female , Heart Ventricles/diagnostic imaging , Humans , Pregnancy , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...