Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Language
Publication year range
1.
Heliyon ; 10(4): e25406, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38370176

ABSTRACT

Objective: This study aims to develop a predictive model using artificial intelligence to estimate the ICU length of stay (LOS) for Congenital Heart Defects (CHD) patients after surgery, improving care planning and resource management. Design: We analyze clinical data from 2240 CHD surgery patients to create and validate the predictive model. Twenty AI models are developed and evaluated for accuracy and reliability. Setting: The study is conducted in a Brazilian hospital's Cardiovascular Surgery Department, focusing on transplants and cardiopulmonary surgeries. Participants: Retrospective analysis is conducted on data from 2240 consecutive CHD patients undergoing surgery. Interventions: Ninety-three pre and intraoperative variables are used as ICU LOS predictors. Measurements and main results: Utilizing regression and clustering methodologies for ICU LOS (ICU Length of Stay) estimation, the Light Gradient Boosting Machine, using regression, achieved a Mean Squared Error (MSE) of 15.4, 11.8, and 15.2 days for training, testing, and unseen data. Key predictors included metrics such as "Mechanical Ventilation Duration", "Weight on Surgery Date", and "Vasoactive-Inotropic Score". Meanwhile, the clustering model, Cat Boost Classifier, attained an accuracy of 0.6917 and AUC of 0.8559 with similar key predictors. Conclusions: Patients with higher ventilation times, vasoactive-inotropic scores, anoxia time, cardiopulmonary bypass time, and lower weight, height, BMI, age, hematocrit, and presurgical oxygen saturation have longer ICU stays, aligning with existing literature.

2.
PLoS One ; 15(9): e0238199, 2020.
Article in English | MEDLINE | ID: mdl-32886688

ABSTRACT

BACKGROUND: Congenital heart disease accounts for almost a third of all major congenital anomalies. Congenital heart defects have a significant impact on morbidity, mortality and health costs for children and adults. Research regarding the risk of pre-surgical mortality is scarce. OBJECTIVES: Our goal is to generate a predictive model calculator adapted to the regional reality focused on individual mortality prediction among patients with congenital heart disease undergoing cardiac surgery. METHODS: Two thousand two hundred forty CHD consecutive patients' data from InCor's heart surgery program was used to develop and validate the preoperative risk-of-death prediction model of congenital patients undergoing heart surgery. There were six artificial intelligence models most cited in medical references used in this study: Multilayer Perceptron (MLP), Random Forest (RF), Extra Trees (ET), Stochastic Gradient Boosting (SGB), Ada Boost Classification (ABC) and Bag Decision Trees (BDT). RESULTS: The top performing areas under the curve were achieved using Random Forest (0.902). Most influential predictors included previous admission to ICU, diagnostic group, patient's height, hypoplastic left heart syndrome, body mass, arterial oxygen saturation, and pulmonary atresia. These combined predictor variables represent 67.8% of importance for the risk of mortality in the Random Forest algorithm. CONCLUSIONS: The representativeness of "hospital death" is greater in patients up to 66 cm in height and body mass index below 13.0 for InCor's patients. The proportion of "hospital death" declines with the increased arterial oxygen saturation index. Patients with prior hospitalization before surgery had higher "hospital death" rates than who did not required such intervention. The diagnoses groups having the higher fatal outcomes probability are aligned with the international literature. A web application is presented where researchers and providers can calculate predicted mortality based on the CgntSCORE on any web browser or smartphone.


Subject(s)
Artificial Intelligence , Heart Defects, Congenital/mortality , Heart Defects, Congenital/surgery , Preoperative Period , Risk Assessment/methods , Female , Humans , Male , Pilot Projects , Registries , Retrospective Studies
3.
Braz J Cardiovasc Surg ; 33(3): 224-232, 2018.
Article in English | MEDLINE | ID: mdl-30043914

ABSTRACT

OBJECTIVE: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. METHODS: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. RESULTS: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. CONCLUSION: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Subject(s)
Cannula/standards , Cardiopulmonary Bypass/instrumentation , Oxygenators/standards , Blood Flow Velocity/physiology , Cardiopulmonary Bypass/methods , Equipment Design , Equipment Safety , Hemodilution , Humans , Models, Cardiovascular , Pediatrics/instrumentation , Reference Standards , Reproducibility of Results , Temperature , Time Factors , Venous Pressure/physiology
4.
Rev. bras. cir. cardiovasc ; 33(3): 224-232, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-958406

ABSTRACT

Abstract Objective: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. Methods: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. Results: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. Conclusion: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Subject(s)
Humans , Oxygenators/standards , Cardiopulmonary Bypass/instrumentation , Cannula/standards , Pediatrics/instrumentation , Reference Standards , Temperature , Time Factors , Venous Pressure/physiology , Blood Flow Velocity/physiology , Cardiopulmonary Bypass/methods , Reproducibility of Results , Equipment Design , Equipment Safety , Hemodilution , Models, Cardiovascular
SELECTION OF CITATIONS
SEARCH DETAIL
...