Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Commun ; 11(1): 2963, 2020 Jun 11.
Article in English | MEDLINE | ID: mdl-32528164

ABSTRACT

Efficiently entangling pairs of qubits is essential to fully harness the power of quantum computing. Here, we devise an exact protocol that simultaneously entangles arbitrary pairs of qubits on a trapped-ion quantum computer. The protocol requires classical computational resources polynomial in the system size, and very little overhead in the quantum control compared to a single-pair case. We demonstrate an exponential improvement in both classical and quantum resources over the current state of the art. We implement the protocol on a software-defined trapped-ion quantum computer, where we reconfigure the quantum computer architecture on demand. Our protocol may also be extended to a wide variety of other quantum computing platforms.

2.
Phys Med Biol ; 65(20): 205004, 2020 10 12.
Article in English | MEDLINE | ID: mdl-32438353

ABSTRACT

Thermal ablation by ultrasound is being explored as a local therapy for cancers of soft tissue, such as the liver or breast. One challenge for these treatments are off-target effects, including heating outside of the intended region or skin burns. Improvements in heating efficiency can mitigate these undesired outcomes, and here, we describe methods for using phase-shift nanodroplets (PSNDs) with multi-focus sonications to enhance volumetric ablation and ablation efficiency at constant powers while increasing the pre-focal temperature by less than 6 [Formula: see text]C. Multi-focus ablation with 4 foci performed the best and achieved a mean ablation volume of 120.2 ± 22.4 mm3 and ablation efficiency of 0.04 mm3 J-1 versus an ablation volume of 61.2 ± 21.16 mm3 and ablation efficiency of 0.02 mm3 J-1 in single focus case. The combined use of PSNDs with multi-focal ultrasound presented here is a new approach to increasing ablation efficiency while reducing off-target effects and could be generally applied in various focused ultrasound thermal ablation treatments.


Subject(s)
High-Intensity Focused Ultrasound Ablation/methods , Hot Temperature , Nanotechnology , Sonication , Humans , Liver/surgery
3.
Sci Rep ; 9(1): 16235, 2019 11 07.
Article in English | MEDLINE | ID: mdl-31700021

ABSTRACT

The aim of this study was to improve the sensitivity of magnetic resonance-acoustic radiation force imaging (MR-ARFI) to minimize pressures required to localize focused ultrasound (FUS) beams, and to establish safe FUS localization parameters for ongoing ultrasound neuromodulation experiments in living non-human primates. We developed an optical tracking method to ensure that the MR-ARFI motion-encoding gradients (MEGs) were aligned with a single-element FUS transducer and that the imaged slice was prescribed at the optically tracked location of the acoustic focus. This method was validated in phantoms, which showed that MR-ARFI-derived displacement sensitivity is maximized when the MR-ARFI MEGs were maximally aligned with the FUS propagation direction. The method was then applied in vivo to acquire displacement images in two healthy macaque monkeys (M fascicularis) which showed the FUS beam within the brain. Temperature images were acquired using MR thermometry to provide an estimate of in vivo brain temperature changes during MR-ARFI, and pressure and thermal simulations of the acoustic pulses were performed using the k-Wave package which showed no significant heating at the focus of the FUS beam. The methods presented here will benefit the multitude of transcranial FUS applications as well as future human applications.


Subject(s)
Acoustics , Magnetic Resonance Imaging/adverse effects , Safety , Skull , Ultrasonic Waves/adverse effects , Animals , Brain/diagnostic imaging , Macaca , Temperature
4.
Sci Rep ; 8(1): 7993, 2018 05 22.
Article in English | MEDLINE | ID: mdl-29789605

ABSTRACT

Focused ultrasound (FUS) has gained recognition as a technique for non-invasive neuromodulation with high spatial precision and the ability to both excite and inhibit neural activity. Here we demonstrate that MRI-guided FUS is capable of exciting precise targets within areas 3a/3b in the monkey brain, causing downstream activations in off-target somatosensory and associated brain regions which are simultaneously detected by functional MRI. The similarity between natural tactile stimulation-and FUS- evoked fMRI activation patterns suggests that FUS likely can excite populations of neurons and produce associated spiking activities that may be subsequently transmitted to other functionally related touch regions. The across-region differences in fMRI signal changes relative to area 3a/3b between tactile and FUS conditions also indicate that FUS modulated the tactile network differently. The significantly faster rising (>1 sec) fMRI signals elicited by direct FUS stimulation at the targeted cortical region suggest that a different neural hemodynamic coupling mechanism may be involved in generating fMRI signals. This is the first demonstration of imaging neural excitation effects of FUS with BOLD fMRI on a specific functional circuit in non-human primates.


Subject(s)
Brain Mapping/methods , Brain/anatomy & histology , Magnetic Resonance Imaging/methods , Nerve Net/anatomy & histology , Physical Stimulation/methods , Sensory Receptor Cells/cytology , Ultrasonography, Interventional/methods , Animals , Brain/diagnostic imaging , Brain/physiology , Deep Brain Stimulation/methods , Macaca fascicularis , Magnetic Resonance Imaging, Interventional/methods , Male , Nerve Net/diagnostic imaging , Nerve Net/physiology , Sensory Receptor Cells/physiology , Somatosensory Cortex/physiology
5.
Phys Med Biol ; 63(10): 105016, 2018 05 17.
Article in English | MEDLINE | ID: mdl-29667598

ABSTRACT

Transcranial focused ultrasound (FUS) is a non-invasive technique for therapy and study of brain neural activation. Here we report on the design and characterization of a new MR-guided FUS transducer for neuromodulation in non-human primates at 650 kHz. The array is randomized with 128 elements 6.6 mm in diameter, radius of curvature 7.2 cm, opening diameter 10.3 cm (focal ratio 0.7), and 46% coverage. Simulations were used to optimize transducer geometry with respect to focus size, grating lobes, and directivity. Focus size and grating lobes during electronic steering were quantified using hydrophone measurements in water and a three-axis stage. A novel combination of optical tracking and acoustic mapping enabled measurement of the 3D pressure distribution in the cortical region of an ex vivo skull to within ~3.5 mm of the surface, and allowed accurate modelling of the experiment via non-homogeneous 3D acoustic simulations. The data demonstrates acoustic focusing beyond the skull bone, with the focus slightly broadened and shifted proximal to the skull. The fabricated design is capable of targeting regions within the S1 sensorimotor cortex of macaques.


Subject(s)
Magnetic Resonance Imaging/methods , Neural Pathways , Skull/diagnostic imaging , Skull/radiation effects , Transcutaneous Electric Nerve Stimulation/methods , Ultrasonography, Doppler, Transcranial/instrumentation , Ultrasonography, Doppler, Transcranial/methods , Animals , Humans , Primates , Skull/pathology
6.
J Ther Ultrasound ; 5: 12, 2017.
Article in English | MEDLINE | ID: mdl-28413682

ABSTRACT

BACKGROUND: Mild-hyperthermia therapy (40-45 °C) with high-intensity focused ultrasound (HIFU) is a technique being considered in a number of different treatments such as thermally activated drug delivery, immune-stimulation, and as a chemotherapy adjuvant. Mechanical damage and loss of cell viability associated with HIFU-induced acoustic cavitation may pose a risk during these treatments or may hinder their success. Here we present a method that achieves mild heating and reduces cavitation by using a multi-focused HIFU beam. We quantify cavitation level and temperature rise in multi-focal sonications and compare it to single-focus sonications at the transducer geometric focus. METHODS: Continuous wave sonications were performed with the Sonalleve V2 transducer in gel phantoms and pork at 5, 10, 20, 40, 60, 80 acoustic watts for 30 s. Cavitation activity was measured with two ultrasound (US) imaging probes, both by computing the raw channel variance and using passive acoustic mapping (PAM). Temperature rise was measured with MR thermometry at 3 T. Cavitation and heating were compared for single- and multi-focal sonication geometries. Multi-focal sonications used four points equally spaced on a ring of either 4 mm or 8 mm diameter. Single-focus sonications were not steered. RESULTS: Multi-focal sonication generated distinct foci that were visible in MRI thermal maps in both phantoms and pork, and visible in PAM images in phantoms only. Cavitation activity (measured by channel variance) and mean PAM image value were highly correlated (r > 0.9). In phantoms, cavitation exponentially decreased over the 30-second sonication, consistent with depletion of cavitation nuclei. In pork, sporadic spikes signaling cavitation were observed with single focusing only. In both materials, the widest beam reduced average and peak cavitation level by a factor of two or more at each power tested when compared to a single focus. The widest beam reduced peak temperature by at least 10 °C at powers above 5 W, and created heating that was more spatially diffuse than single focus, resulting in more voxels in the mild heating (3-8 °C) range. CONCLUSIONS: Multi-focal HIFU can be used to achieve mild temperature elevation and reduce cavitation activity.

7.
8.
J Ther Ultrasound ; 4(1): 22, 2016.
Article in English | MEDLINE | ID: mdl-27597889

ABSTRACT

BACKGROUND: MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. METHODS: A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. RESULTS: The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus visualization was achieved with acoustic radiation force imaging. CONCLUSIONS: We developed an MRgFUS platform for small-animal treatments that robustly delivers accurate, precise, and controllable sonications over extended time periods. This system is an open source and could increase the availability of low-cost small-animal systems to interdisciplinary researchers seeking to develop new MRgFUS applications and technology.

SELECTION OF CITATIONS
SEARCH DETAIL
...