Results 1 - 16 de 16
Filter
1.
J Occup Environ Hyg ; : 1-9, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38901026

ABSTRACT

This study compared the effectiveness of N95 FFRs in providing respiratory protection for healthcare staff in a residential aged care facility (RACF) and tertiary teaching hospital (TTH) who had previously passed their occupational respiratory protection program fit test. A total of 126 healthcare workers who were regularly using N95 FFRs and who had previously passed a fit test participated in this comparative study. In this study, participants were again fit tested with the PortaCount machine, and their self-assessed tolerability of wearing an N95 FFR was assessed using a standardized questionnaire. The main outcome measures included the pass rate of the fit test and the assessment of tolerability and comfort of the N95 FFR. Across all participants, the fit test pass rate was low (27%), indicating persistent gaps in respiratory protection programs for healthcare workers during the ongoing COVID-19 pandemic. Hospital workers were 3.7 times more likely to pass the test compared to their counterparts in RACFs (p < 0.001). It was also found that workers in RACFs reported higher levels of discomfort and overall dissatisfaction with N95 FFRs compared to hospital staff. These findings highlight the need for targeted interventions and improvements in respiratory protection practices beyond annual fit testing, particularly in RACFs, to ensure the safety of healthcare workers and the vulnerable population they serve.

2.
J Cardiovasc Electrophysiol ; 35(6): 1229-1231, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38654418

ABSTRACT

BACKGROUND: Real-time signal processing has to date been difficult to implement in the clinical electrophysiology laboratory. To date, no open access software solutions are available in electrophysiology (EP) laboratories to facilitate real-time intraprocedural signal analysis. We aimed to develop an open access, scalable Python plug-in to allow real-time signal processing during human EP procedures. METHODS AND RESULTS: A Python-based plug in for the widely available EnsiteX mapping system was developed. This plug-in utilized the LiveSync feature of the system to allow real-time signal analysis. An open access library was developed to allow end-users to implement real-time signal analysis using this platform, implemented in the Python programming language https://github.com/anand9176/WaveWatch5000Public. CONCLUSION: We have developed and demonstrated the feasibility of a readily scalable and open-access Python-based plug in to an electroanatomic mapping system (EnSiteX) to allow real-time processing and display of electrogram (EGM) based information for the procedural electrophysiologist to view intraprocedurally in the electrophysiology laboratory. The availability, to the clinician, of traditional and novel EGM-based metrics at the time of intervention, such as atrial fibrillation ablation, allows for key mechanistic insights into critical unresolved questions regarding arrhythmia mechanism.


Subject(s)
Action Potentials , Electrophysiologic Techniques, Cardiac , Signal Processing, Computer-Assisted , Humans , Time Factors , Software , Predictive Value of Tests , Heart Rate , Feasibility Studies
3.
IEEE Open J Eng Med Biol ; 5: 198-204, 2024.
Article in English | MEDLINE | ID: mdl-38606401

ABSTRACT

OBJECTIVE: This study addressed the problem of objectively detecting leaks in P2 respirators at point of use, an essential component for healthcare workers' protection. To achieve this, we explored the use of infra-red (IR) imaging combined with machine learning algorithms on the thermal gradient across the respirator during inhalation. RESULTS: The study achieved high accuracy in predicting pass or fail outcomes of quantitative fit tests for flat-fold P2 FFRs. The IR imaging methods surpassed the limitations of self fit-checking. CONCLUSIONS: The integration of machine learning and IR imaging on the respirator itself demonstrates promise as a more reliable alternative for ensuring the proper fit of P2 respirators. This innovative approach opens new avenues for technology application in occupational hygiene and emphasizes the need for further validation across diverse respirator styles. SIGNIFICANCE STATEMENT: Our novel approach leveraging infra-red imaging and machine learning to detect P2 respirator leaks represents a critical advancement in occupational safety and healthcare workers' protection.

4.
JACC Clin Electrophysiol ; 10(2): 306-315, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38206259

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) faces challenges in achieving reliable and safe deployments. Complex interactions between tissue and lead tip can result in endocardial entanglement, a drill effect that prevents penetration. No verified ex vivo model exists to quantitatively assess this relationship. OBJECTIVES: The purpose of this study was to quantitatively characterize CSP lead tip to tissue responses for 4 commonly used leads. METHODS: CSP leads (from Medtronic, Biotronik, Boston Scientific, and Abbott) were examined for helix rotation efficiency in ex vivo ovine right ventricular septa. A custom jig was utilized for rotation measurements. Fifteen turns were executed, documenting tissue-interface changes every 90° using high-resolution photography. Response curves (input rotation vs helix rotation) were evaluated using piecewise linear regression, with a focus on output vs input response slopes and torque breakpoint events. RESULTS: We analyzed 3,840 quarter-turn CSP insertions with 4 different lead types. Helix rotations were consistently less than input: Abbott Tendril = 0.21:1, Medtronic 3830 = 0.21:1, Biotronik Solia = 0.47:1, and Boston Scientific Ingevity = 0.56:1. Torque breakpoint events were observed on average 7.22 times per insertion (95% CI: 6.08-8.35; P = NS) across all leads. In 57.8% of insertions (37 of 64), uncontrolled torque breakpoint events occurred, signaling unexpected excess helix rotations. CONCLUSIONS: Using a robust ex vivo model, we revealed a muted helix rotation response compared with input turns on the lead, and frequent torque change events during insertion. This is critical for CSP implanters, emphasizing the potential for unexpected torque breakpoint events, and suggesting the need for novel lead designs or deployment methods to enhance CSP efficiency and safety.


Subject(s)
Heart Conduction System , Humans , Animals , Sheep , Torque , Heart Conduction System/physiology , Boston
5.
Article in English | MEDLINE | ID: mdl-38083259

ABSTRACT

Atrial fibrillation (AF) strikingly possesses the ability to abruptly transition into more organized electrical activity and spontaneously terminate, even after persisting for long periods. Despite being central to the clinical behavior and treatment of AF, these phenomena remain incompletely understood. In this paper, we hypothesized that the spontaneous termination of AF may represent a type of percolation phase transition, which is more likely to occur when a domain spanning cluster of refractory sites in the atrium are connected (called a 'percolation cluster'). This was assessed in n=50 computational simulations of AF developed using the Aliev-Panfilov (APV) 2-dimensional cell model. In self-terminating simulations of AF, it was found that the average refractory cluster size, χ(p) (median: 647.7), and the largest refractory cluster size, M1 (median: 1702.3), abruptly increased just prior to AF spontaneously terminating, indicating the onset of the formation of a domain spanning percolation cluster. In contrast, simulations of sustained AF did not demonstrate an increase in χ(p) (median: 463.0) and M1 (median: 1448.2). Self-terminating AF simulations also demonstrated hallmark properties characteristic of a percolation phase transition, such as an abrupt increase in χ(p) at the critical occupation probability pc. The cluster size distribution was also shown to obey a power law for various occupation probabilities p, also indicative of a percolation phase transition. Collectively, these properties suggests that the spontaneous termination of AF could be a form of percolation phase transition, which could provide new insights for AF treatment.


Subject(s)
Atrial Fibrillation , Humans , Pilot Projects , Heart Atria
6.
J Occup Environ Hyg ; 20(7): 304-314, 2023 07.
Article in English | MEDLINE | ID: mdl-37084394

ABSTRACT

Correctly fitting N95 filtering facepiece respirators (FFRs) have become increasingly important in health care throughout the COVID-19 pandemic. We evaluated the hypothesis that personalized 3D-printed frames could improve N95 FFRs quantitative fit test pass rates and test scores in health care workers (HCWs). HCWs were recruited at a tertiary hospital in Adelaide, Australia (ACTRN 12622000388718). A mobile iPhone camera + app was used to produce 3D scans of volunteers' faces, which were then imported into a software program to produce personalized virtual scaffolds suited to each user's face and their unique anatomical features. These virtual scaffolds were printed on a commercially available 3D printer, producing plastic (and then silicone-coated, biocompatible) frames that can be fitted inside existing hospital supply N95 FFR. The primary endpoint was improved pass rates on quantitative fit testing, comparing participants wearing an N95 FFR alone (control 1) with participants wearing the frame + N95 FFR (intervention 1). The secondary endpoint was the fit factor (FF) in these groups, and R-COMFI respirator comfort and tolerability survey scores. N = 66 HCWs were recruited. The use of intervention 1 increased overall fit test pass rates to 62/66 (93.8%), compared to 27/66 (40.9%) for controls. (OR for pFF pass 20.89 (95%CI: 6.77, 64.48, p < 0.001.) Average FF increased, with the use of intervention 1-179.0 (95%CI: 164.3,193.7), compared to 85.2 (95%CI: 70.4,100.0) with control 1. Pass rates and FF were improved with intervention 1 compared to control 1 for all stages of the fit-test: bending, talking, side-to-side, and up-down motion. (p < 0.001 all stages). Tolerability and comfort of the frame were evaluated with the validated R-COMFI respirator comfort score, showing improvement with the frame compared to N95 FFR alone (p = 0.006). Personalized 3D-printed face frames decrease leakage, improve fit testing pass rates and FF, and provide improved comfort compared to the N95 FFR alone. Personalized 3D-printed face frames represent a rapidly scalable new technology to decrease FFR leakage in HCW and potentially the wider population.


Subject(s)
COVID-19 , Occupational Exposure , Respiratory Protective Devices , Humans , N95 Respirators , Pandemics , Cross-Over Studies , Prospective Studies , Occupational Exposure/prevention & control , COVID-19/prevention & control , Equipment Design , Printing, Three-Dimensional
7.
Aust J Gen Pract ; 512022 02 11.
Article in English | MEDLINE | ID: mdl-35172324

ABSTRACT

The authors report the results of a pilot trial of quantitative N95 respirator mask fit testing in metropolitan general practice and how fit test failures were managed.


Subject(s)
General Practice , Occupational Exposure , Respiratory Protective Devices , Australia , Humans , Masks , Ventilators, Mechanical
9.
JTCVS Open ; 7: 141-154, 2021 Sep.
Article in English | MEDLINE | ID: mdl-36003726

ABSTRACT

Background: Both catheter and surgical ablation strategies offer effective treatments of atrial fibrillation (AF). The hybrid (joint surgical and catheter) ablation for AF is an emerging rhythm control strategy. We sought to determine the efficacy and safety of hybrid ablation of AF. Methods: Systematic review and meta-analysis interrogating PubMed, EMBASE, and Cochrane databases from January 1, 1991, to November 30, 2017, using the following search terms: "Cox-maze," "mini-maze," "ablation methods (including radiofrequency, cryoablation, cryomaze)," and "surgery." Included studies required ablation procedures to be hybrid and report rhythm follow-up. Results: We included 925 patients with AF (38% persistent, 51% longstanding persistent) from 22 single-center studies (mean follow-up of 19 months). The surgical lesion set consisted of pulmonary vein isolation (n = 11) or box lesion (n = 11) with variable additional linear ablation. This was followed by sequential (n = 9), staged (n = 9), or combination (n = 4) catheter-based ablation to ensure isolation of pulmonary veins and to facilitate additional ablation or consolidation of surgically ablated lines. Overall, sinus rhythm maintenance was 79.4% (95% confidence interval [CI], 72.4-85.7] and 70.7% (95% CI, 62.2-78.7) with and without antiarrhythmic drugs, respectively at 19 ± 25 (range, 6-128) months. The use of the bipolar AtriCure Synergy system and left atrial appendage exclusion conferred superior rhythm outcome without antiarrhythmic drugs (P ≤ .01). The overall complication rate was 6.5% (95% CI, 3.4-10.2): mortality 0.2% (95% CI, 0-0.9); stroke 0.3% (95% CI, 0-1.1); reoperation for bleeding 1.6% (95% CI, 0.6-3.0); permanent pacing ~0% (95% CI, 0-0.5); conversion to sternotomy 0.3% (95% CI, 0-1.1); atrioesophageal fistula ~0% (95% CI, 0-0.5); and phrenic nerve injury 0.3% (95% CI, 0-1.1). Conclusions: Hybrid ablation therapy for AF demonstrates favorable rhythm outcome with acceptable complication rates.

10.
Circ Arrhythm Electrophysiol ; 12(12): e007569, 2019 12.
Article in English | MEDLINE | ID: mdl-31813270

ABSTRACT

BACKGROUND: Despite a century of research, no clear quantitative framework exists to model the fundamental processes responsible for the continuous formation and destruction of phase singularities (PS) in cardiac fibrillation. We hypothesized PS formation/destruction in fibrillation could be modeled as self-regenerating Poisson renewal processes, producing exponential distributions of interevent times governed by constant rate parameters defined by the prevailing properties of each system. METHODS: PS formation/destruction were studied in 5 systems: (1) human persistent atrial fibrillation (n=20), (2) tachypaced sheep atrial fibrillation (n=5), (3) rat atrial fibrillation (n=4), (5) rat ventricular fibrillation (n=11), and (5) computer-simulated fibrillation. PS time-to-event data were fitted by exponential probability distribution functions computed using maximum entropy theory, and rates of PS formation and destruction (λf/λd) determined. A systematic review was conducted to cross-validate with source data from literature. RESULTS: In all systems, PS lifetime and interformation times were consistent with underlying Poisson renewal processes (human: λf, 4.2%/ms±1.1 [95% CI, 4.0-5.0], λd, 4.6%/ms±1.5 [95% CI, 4.3-4.9]; sheep: λf, 4.4%/ms [95% CI, 4.1-4.7], λd, 4.6%/ms±1.4 [95% CI, 4.3-4.8]; rat atrial fibrillation: λf, 33%/ms±8.8 [95% CI, 11-55], λd, 38%/ms [95% CI, 22-55]; rat ventricular fibrillation: λf, 38%/ms±24 [95% CI, 22-55], λf, 46%/ms±21 [95% CI, 31-60]; simulated fibrillation λd, 6.6-8.97%/ms [95% CI, 4.1-6.7]; R2≥0.90 in all cases). All PS distributions identified through systematic review were also consistent with an underlying Poisson renewal process. CONCLUSIONS: Poisson renewal theory provides an evolutionarily preserved universal framework to quantify formation and destruction of rotational events in cardiac fibrillation.


Subject(s)
Action Potentials , Atrial Fibrillation/physiopathology , Heart Conduction System/physiopathology , Heart Rate , Models, Cardiovascular , Ventricular Fibrillation/physiopathology , Animals , Biological Evolution , Computer Simulation , Disease Models, Animal , Humans , Multicenter Studies as Topic , Observational Studies as Topic , Rats , Reproducibility of Results , Sheep, Domestic , Stochastic Processes , Time Factors , Ventricular Fibrillation/diagnosis
11.
Interact Cardiovasc Thorac Surg ; 28(1): 85-93, 2019 01 01.
Article in English | MEDLINE | ID: mdl-29982423

ABSTRACT

OBJECTIVES: Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to 'cut-and-sew'. Catheter ablation studies demonstrate a relationship between lesion depth and contact force. We hypothesized that contact force and lesion depth are dependent on design of the bipolar surgical RF clamps. METHODS: Hinged and parallel jaw style RF clamps were studied. Muscle samples were clamped with pressure-sensitive film at increasing tissue thicknesses. Films were analysed determining clamp pressure profiles. A sheep model was utilized for ablation testing using each clamp style until the device indicated transmurality. Separate muscle areas had 1, 2 or 3 burns applied. The muscle was excised, sectioned every 1 cm and stained for lesion depth and fat thickness analysis. RESULTS: Pressure profiling comparing the proximal and distal segments of each clamp style demonstrated only one statistically significant difference in the parallel clamp; the hinged clamp had statistically significant differences (P ≤ 0.03) for all tissue thicknesses. There was no evidence for differences in the proximal lesion depth of both clamps (P = 0.13) but deeper distally in the parallel clamp (10.17 mm vs 8.02 mm, P = 0.003). The logistic regression analysis demonstrated increased odds of transmurality with parallel clamps at 1, 2 or 3 burns (P = 0.03, P = 0.003 and P = 0.002). Every 1 mm increase in overlying fat decreased likelihood of transmurality by 11% (P < 0.05). CONCLUSIONS: The parallel and hinged clamps have different pressure profiles with higher likelihood of transmurality using the parallel clamp. Fat reduces the ability of RF to deliver a transmural lesion. These findings have implications for optimal surgical RF ablation technique.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Heart Conduction System/surgery , Animals , Atrial Fibrillation/physiopathology , Disease Models, Animal , Electrocardiography , Equipment Design , Sheep
12.
J Electrocardiol ; 53: 18-27, 2019.
Article in English | MEDLINE | ID: mdl-30580097

ABSTRACT

BACKGROUND: The potential utility of entropy (En) for atrial fibrillation (AF) mapping has been demonstrated in previous studies by multiple groups, where an association between high bipolar electrogram (EGM) entropy and the pivot of rotors has been shown. Though En is potentially attractive new approach to ablation, no studies have examined its temporal stability and specificity, which are critical to the application of entropy to clinical ablation. In the current study, we sought to objectively measure the temporal stability and specificity of bipolar EGM entropy in medium to long term recordings using three studies: i) a human basket catheter AF study, ii) a tachypaced sheep AF study and iii) a computer simulation study. OBJECTIVE: To characterize the temporal dynamics and specificity of Approximate, Sample and Shannon entropy (ApEn/SampEn/ShEn) in human (H), sheep (S), and computer simulated AF. METHODS: 64-electrode basket bi-atria sustained AF recordings (H:15 min; S:40 min) were separated into 5 s segments. ShEn/ApEn/SampEn were computed, and co-registered with NavX 3D maps. Temporal stability was determined in terms of: (i) global pattern stability of En and (ii) the relative stability the top 10% of En regions. To provide mechanistic insights into underlying mechanisms, stability characteristics were compared to models depicting various propagation patterns. To verify these results, cross-validation was performed across multiple En algorithms, across species, and compared with dominant frequency (DF) temporal characteristics. The specificity of En was also determined by looking at the association of En to rotors and areas of wave cross propagation. RESULTS: Episodes of AF were analysed (H:26 epochs, 6040 s; S:15 epochs, 14,160 s). The global pattern of En was temporally unstable (CV- H:13.42% ±â€¯4.58%; S:14.13% ±â€¯8.13%; Friedman- H: p > 0.001; S: p > 0.001). However, within this dynamic flux, the top 10% of ApEn/SampEn/ShEn regions were relatively temporally stable (Kappa >0.6) whilst the top 10% of DF regions were unstable (Kappa <0.06). In simulated AF scenarios, the experimental data were optimally reproduced in the context of an AF pattern with stable rotating waves surrounded by wavelet breakup (Kappa: 0.610; p < 0.0001). CONCLUSION: En shows global temporal instability, however within this dynamic flux, the top 10% regions exhibited relative temporal stability. This suggests that high En regions may be an appealing ablation target. Despite this, high En was associated with not just the pivot of rotors but also with areas of cross propagation, which suggests the need for future work before clinical application is possible.


Subject(s)
Atrial Fibrillation/physiopathology , Electrocardiography , Algorithms , Animals , Computer Simulation , Entropy , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Humans , Models, Cardiovascular , Sensitivity and Specificity , Sheep, Domestic , Time Factors
13.
J Arrhythm ; 33(1): 40-48, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28217228

ABSTRACT

BACKGROUND: Sequentially mapped complex fractionated atrial electrograms (CFAE) and dominant frequency (DF) sites have been targeted during catheter ablation for atrial fibrillation (AF). However, these strategies have yielded variable success and have not been shown to correlate consistently with AF dynamics. Here, we evaluated whether the spatiotemporal stability of CFAE and DF may be a better marker of AF sustenance and termination. METHODS: Eighteen sheep with 12 weeks of "one-kidney, one-clip" hypertension underwent open-chest studies. A total of 42 self-terminating (28-100 s) and 6 sustained (>15 min) AF episodes were mapped using a custom epicardial plaque and analyzed in 4-s epochs for CFAE, using the NavX CFE-m algorithm, and DF, using a Fast Fourier Transform. The spatiotemporal stability index (STSI) was calculated using the intraclass correlation coefficient of consecutive AF epochs. RESULTS: A total of 67,733 AF epochs were analyzed. During AF initiation, mean CFE-m and the STSI of CFE-m/DF were similar between sustained and self-terminating episodes, although median DF was higher in sustained AF (p=0.001). During sustained AF, the STSI of CFE-m increased significantly (p=0.02), whereas mean CFE-m (p=0.5), median DF (p=0.07), and the STSI of DF remained unchanged (p=0.5). Prior to AF termination, the STSI of CFE-m was significantly lower (p<0.001), with a physiologically non-significant decrease in median DF (-0.3 Hz, p=0.006) and no significant changes in mean CFE-m (p=0.14) or the STSI of DF (p=0.06). CONCLUSIONS: Spatiotemporal stabilization of CFAE favors AF sustenance and its destabilization heralds AF termination. The STSI of CFE-m is more representative of AF dynamics than are the STSI of DF, sequential mean CFE-m, or median DF.

14.
PLoS One ; 9(11): e110662, 2014.
Article in English | MEDLINE | ID: mdl-25401331

ABSTRACT

BACKGROUND: Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. OBJECTIVE: To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. METHODS AND RESULTS: We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. CONCLUSIONS: The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour.


Subject(s)
Models, Theoretical , Algorithms , Computer Simulation
15.
Circ Arrhythm Electrophysiol ; 7(1): 90-8, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24382409

ABSTRACT

BACKGROUND: Surviving myocytes within scar may form channels that support ventricular tachycardia (VT) circuits. There are little data on the properties of channels that comprise VT circuits and those that are non-VT supporting channels. METHODS AND RESULTS: In 22 patients with ischemic cardiomyopathy and VT, high-density mapping was performed with the PentaRay catheter and Ensite NavX system during sinus rhythm. A channel was defined as a series of matching pace-maps with a stimulus (S) to QRS time of ≥40 ms. Sites were determined to be part of a VT channel if there were matching pace-maps to the VT morphology. This was confirmed with entrainment mapping when possible. Of the 238 channels identified, 57 channels corresponded to an inducible VT. Channels that were part of a VT circuit were more commonly located within dense scar than non-VT channels (97% versus 82%; P=0.036). VT supporting channels were of greater length (mean±SEM, 53±5 versus 33±4 mm), had higher longest S-QRS (130±12 versus 82±12 ms), longer conduction time (103±14 versus 43±13 ms), and slower conduction velocity (0.87±0.23 versus 1.39±0.21 m/s) than non-VT channels (P<0.001). Of all the fractionated, late, and very late potentials located in scar, only 21%, 26%, and 29%, respectively, were recorded within VT channels. CONCLUSIONS: High-density mapping shows substantial differences among channels in ventricular scar. Channels supporting VT are more commonly located in dense scar, longer than non-VT channels, and have slower conduction velocity. Only a minority of scar-related potentials participate in the VT supporting channels.


Subject(s)
Cardiomyopathies/etiology , Cicatrix/etiology , Heart Conduction System/physiopathology , Myocardial Ischemia/complications , Tachycardia, Ventricular/etiology , Voltage-Sensitive Dye Imaging , Action Potentials , Aged , Cardiac Pacing, Artificial , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Catheter Ablation , Cicatrix/diagnosis , Cicatrix/physiopathology , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Heart Conduction System/pathology , Humans , Kinetics , Male , Middle Aged , Myocardial Ischemia/diagnosis , Myocardial Ischemia/physiopathology , Predictive Value of Tests , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery , Treatment Outcome
16.
Australas Phys Eng Sci Med ; 29(1): 53-6, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16623221

ABSTRACT

This paper describes the design and testing of a new hand strain-gauge based dynamometer. The design is portable and capable of measuring grip strengths from 12.5 to 800N. The dynamometer is independent of point of application of the grip force. Finite element modelling and experimental testing were used to verify the mechanical system's suitability. The dynamometer was designed for input to a PDA to allow full portability of the device.


Subject(s)
Biomechanical Phenomena/instrumentation , Exercise Test/instrumentation , Hand Strength/physiology , Hand/physiology , Muscle Contraction/physiology , Transducers , Equipment Design , Exercise Test/methods , Humans , Reproducibility of Results , Sensitivity and Specificity