Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Hernia ; 28(1): 261-267, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37368184

ABSTRACT

PURPOSE: In case of soft tissue sarcomas (STS), an en-bloc resection with safe margins is recommended. To ensure safe removal without tumor rupture, STS of the groin area, retroperitoneal or pelvic mesenchymal tumors may require incision or resection of the inguinal ligament. Solid reconstruction is mandatory to prevent early and late postoperative femoral hernias. We present here a new technique of inguinal ligament reconstruction. METHODS: Between September 2020 and September 2022, patients undergoing incision and/or resection of inguinal ligaments during a wide en-bloc resection of STS of the groin area in the Department of General Surgery in Strasbourg were included. All patients had an inguinal ligament reconstruction with biosynthetic slowly resorbable mesh shaped as a hammock, pre- or intraperitoneally, associated or not with loco-regional pedicled muscular flaps. RESULTS: A total of 7 hammock mesh reconstructions were performed. One or several flaps were necessary in 57% of cases (4 patients): either for inguinal ligament reconstruction only (n = 1), for recovering of femoral vessels (n = 1), and for both ligament reconstruction and defect covering (n = 2). The major morbidity rate was 14.3% (n = 1), related to a thigh surgical site infection due to sartorius flap infarction. After a median follow-up of 17.8 months (range 7-31), there was neither early nor late occurrence of post-operative femoral hernia. CONCLUSIONS: This is a new surgical tool for inguinal ligament reconstruction with the implementation of a biosynthetic slowly resorbable mesh shaped as a hammock, which should be compared to other techniques.


Subject(s)
Hernia, Femoral , Hernia, Inguinal , Neoplasms , Humans , Groin/surgery , Surgical Mesh , Herniorrhaphy/methods , Hernia, Inguinal/surgery , Ligaments/surgery , Hernia, Femoral/surgery , Neoplasms/surgery
2.
Hernia ; 27(2): 387-394, 2023 04.
Article in English | MEDLINE | ID: mdl-35536373

ABSTRACT

PURPOSE: To analyze the incisional hernia recurrence rate at a long-term follow-up using a biosynthetic long-term absorbable mesh in patients with a higher risk of surgical infection in a contaminated surgical field. METHODS: This was a retrospective multicentric study. All patients undergoing incisional hernia repair between 2016 and 2018 at 6 participating university centers were included. Patients were classified according to the Ventral Hernia Working Group (VHWG). All consecutive patients who underwent abdominal wall repair using biosynthetic long-term absorbable mesh (Phasix®) in contaminated fields (grade 3 and 4 of the VHWG classification) were included. Patients were followed-up until September 2021. Preoperative, operative, and postoperative data were collected. All patients' surgical site infections (SSIs) and surgical site occurrences (SSOs) were recorded. The primary outcome of interest was the clinical incisional hernia recurrence rate. RESULTS: One hundred and eight patients were included: 77 with VHWG grade 3 (71.3%) and 31 with VHWG grade 4 (28.7%). Median time follow-up was 41 months [24; 63]. Twenty-four patients had clinical recurrence during the follow-up (22.2%). The SSI and SSO rates were 24.1% and 36.1%, respectively. On multivariate analysis, risk factors for incisional hernia recurrence were previous recurrence, mesh location, and postoperative enterocutaneous fistula. CONCLUSIONS: At the 3 year follow-up, the recurrence rate with a biosynthetic absorbable mesh (Phasix®) for incisional hernia repair in high-risk patients (VHWG grade 3 and 4) seemed to be suitable (22.2%). Most complications occurred in the first year, and SSI and SSO rates were low despite high-risk VHWG grading.


Subject(s)
Hernia, Ventral , Incisional Hernia , Humans , Incisional Hernia/surgery , Retrospective Studies , Surgical Mesh/adverse effects , Herniorrhaphy/adverse effects , Hernia, Ventral/surgery , Recurrence , Treatment Outcome , Procollagen-Proline Dioxygenase , Protein Disulfide-Isomerases
3.
J Visc Surg ; 159(4): 279-285, 2022 08.
Article in English | MEDLINE | ID: mdl-34116953

ABSTRACT

BACKGROUND: The aim of this study was to compare, in terms of cost and serious complications, the use of biosynthetic resorbable parietal mesh with biologic mesh in patients undergoing contaminated ventral hernia repair (modified Ventral Hernia Working Group grade 3). Poly-4-hydroxy-butyrate (P4HB) biosynthetic mesh has rarely been the subject of comparative studies in the context of contamination. Data are required to confirm the effects of a transition from biological mesh to biosynthetic resorbable mesh. PATIENTS AND METHODS: A cost-effectiveness analysis was conducted. It was based on a decision analysis model built with clinical and economic data issued from a before-after study that included 94 patients hospitalized for ventral hernia repair at the University Hospital of Strasbourg (France) from June 2011 to February 2018. The effectiveness endpoint was the number of patients presenting with a serious specific complication or a general complication at 6 months. Data for surgical hospitalization stays, home hospitalizations and ambulatory care costs were included. RESULTS: We found fewer serious complications with biosynthetic mesh: 21% versus 33% with biologic mesh. A cost savings of US $5146 was determined. Deterministic sensitivity analyses and a probabilistic analysis confirmed our findings and the robustness of the model. CONCLUSION: P4HB biosynthetic resorbable mesh appeared to be the most effective and the least costly option. Additional data will be needed to confirm the superiority of biosynthetic mesh in terms of the recurrence risk reduction over a longer period.


Subject(s)
Biological Products , Hernia, Ventral , Cost-Benefit Analysis , Hernia, Ventral/surgery , Herniorrhaphy , Humans , Recurrence , Retrospective Studies , Surgical Mesh , Treatment Outcome
4.
Hernia ; 25(4): 1051-1059, 2021 08.
Article in English | MEDLINE | ID: mdl-33492554

ABSTRACT

PURPOSE: To analyze the postoperative morbidity and 1-year recurrence rate of incisional hernia repair using a biosynthetic long-term absorbable mesh in patients at higher risk of surgical infection in a contaminated surgical field. METHODS: All patients undergoing incisional hernia repair in a contaminated surgical field with the use of a biosynthetic long-term absorbable mesh (Phasix®) between May 2016 and September 2018 at six participating university centers were included in this retrospective cohort and were followed-up until September 2019. Regarding the risk of surgical infection, patients were classified according to the modified Ventral Hernia Working Group classification. Preoperative, operative and postoperative data were collected. All patients' surgical site infections (SSIs) and occurrences (SSOs) and recurrence rates were the endpoints of the study. RESULTS: Two hundred and fifteen patients were included: 170 with mVHWG grade 3 (79%) and 45 with mVHWG grade 2 (21%). The SSI and SSO rates at 12 months were 22.3% and 39.5%, respectively. According to the Dindo-Clavien classification, 43 patients (20.0%) had at least one minor complication, and 57 patients (26.5%) had at least one major complication. Among the 121 patients (56.3%) having at least 1 year of follow-up, the clinical recurrence rate was 12.4%. Multivariate analysis showed that a concomitant gastrointestinal procedure was an independent risk factor for surgical infection (OR = 2.61), and an emergency setting was an independent risk factor for major complications (OR = 11.9). CONCLUSION: The use of a biosynthetic absorbable mesh (Phasix®) is safe in a contaminated surgical field, with satisfying immediate postoperative and 1-year results. TRIAL REGISTRATION: The study is registered on Clinical Trial ID: NCT04132986.


Subject(s)
Hernia, Ventral , Incisional Hernia , Hernia, Ventral/surgery , Herniorrhaphy/adverse effects , Humans , Incisional Hernia/epidemiology , Incisional Hernia/etiology , Incisional Hernia/surgery , Recurrence , Retrospective Studies , Surgical Mesh/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...