Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Philos Trans A Math Phys Eng Sci ; 382(2273): 20230208, 2024 Jun 09.
Article in English | MEDLINE | ID: mdl-38736336

ABSTRACT

The selected ice nanoparticle accelerator, SELINA, was used to prepare beams of single ice particles with positive or negative charge. Positively charged particles were prepared from deionized water and 0.05-0.2 molar solutions of sodium chloride in water, and negatively charged ice particles were generated from water without salt. Depending on the electrospray source configuration, the measured particles vary from 50 to 1000 nm in diameter. The kinetic energy per charge for all particles was set to 200 eV by the collisional equilibration in quadrupoles, which resulted in primary velocities up to 600 m/s for the lowest m/z particles. The electrospray ionization and thus particle formation from SELINA become less efficient with increasing salt concentration, resulting in a lower detected particle frequency and size. Good instrument operation is achievable for concentrations below 0.2 M. After we have verified and characterized positively and negatively charged ice particles, we have combined SELINA with a target and time-of-flight spectrometer for a 'proof-of-principle' post acceleration of 120 nm particles towards hypervelocity (v ~ 3000 m/s) and detection of fragments from the particle impact (SELINA-HIMS). General conditions are discussed for the acceleration of particles between 50 and 1000 nm to velocities well above 3000 m/s with SELINA-HIMS instrument. This article is part of the theme issue 'Dust in the Solar System and beyond'.

2.
Angew Chem Int Ed Engl ; 63(4): e202314784, 2024 Jan 22.
Article in English | MEDLINE | ID: mdl-37917653

ABSTRACT

Despite being recognized primarily as an analytical technique, mass spectrometry also has a large potential as a synthetic tool, enabling access to advanced synthetic routes by reactions in charged microdroplets or ionic thin layers. Such reactions are special and proceed primarily at surfaces of droplets and thin layers. Partial solvation of the reactants is usually considered to play an important role for reducing the activation barrier, but many mechanistic details still need to be clarified. In our study, we showcase the synergy between two sequentially applied "preparative mass spectrometry" methods: initiating accelerated reactions within microdroplets during electrospray ionization to generate gaseous ionic intermediates in high abundance, which are subsequently mass-selected and soft-landed to react with a provided reagent on a substrate. This allows the generation of products at a nanomolar scale, amenable to further characterization. In this proof-of-concept study, the contrasting reaction pathways between intrinsically neutral and pre-charged reagents, respectively, both in microdroplets and in layers generated by ion soft-landing are investigated. This provides new insights into the role of partially solvated reagents at microdroplet surfaces for increased reaction rates. Additionally, further insights into reactions of ions of the same polarity under various conditions is obtained.

3.
Curr Opin Biotechnol ; 81: 102948, 2023 06.
Article in English | MEDLINE | ID: mdl-37163825

ABSTRACT

Rapid prototyping of microfluidic chips is a key enabler for controlled biotechnology applications in microspaces, as it allows for the efficient design and production of microfluidic systems. With rapid prototyping, researchers and engineers can quickly create and test new microfluidic chip designs, which can then be optimized for specific applications in biotechnology. One of the key advantages of microfluidic chips for biotechnology is the ability to manipulate and control biological samples in a microspace, which enables precise and controlled experiments under well-defined conditions. This is particularly useful for applications such as cell culture, drug discovery, and diagnostic assays, where precise control over the biological environment is crucial for obtaining accurate results. Established methods, for example, soft lithography, 3D printing, injection molding, as well as other recently highlighted innovative approaches, will be compared and challenges as well as limitations will be discussed. It will be shown that rapid prototyping of microfluidic chips enables the use of advanced materials and technologies, such as smart materials and digital sensors, which can further enhance the capabilities of microfluidic systems for biotechnology applications. Overall, rapid prototyping of microfluidic chips is an important enabling technology for controlled biotechnology applications in microspaces, as well as for upscaling it into macroscopic bioreactors, and its continued development and improvement will play a critical role in advancing the field. The review will highlight recent trends in terms of materials and competing approaches and shed light on current challenges on the way toward integrated microtechnologies. Also, the possibility to easy and direct implementation of novel functions (membranes, functionalization of interfaces, etc.) is discussed.


Subject(s)
Cell Culture Techniques , Microfluidics , Microfluidics/methods , Biotechnology , Microtechnology , Printing, Three-Dimensional
4.
J Am Soc Mass Spectrom ; 34(5): 878-892, 2023 May 03.
Article in English | MEDLINE | ID: mdl-37018538

ABSTRACT

Small ice particles play an important role in atmospheric and extraterrestrial chemistry. Circumplanetary ice particles that are encountered by space probes at hypervelocities play a critical role in the determination of surface and subsurface properties of their source bodies. Here we present an apparatus for the generation of low-intensity beams of single mass-selected charged ice particles under vacuum. They are produced via electrospray ionization of water at atmospheric pressure and undergo evaporative cooling when transferred to vacuum through an atmospheric vacuum interface. m/z selection is achieved through two subsequent quadrupole mass filters operated in the variable-frequency mode within a range of m/z values between 8 × 104 and 3 × 107. Velocity and charge of the selected particles are measured using a nondestructive single-pass image charge detector. From the known electrostatic acceleration potentials and settings of the quadrupoles the particle masses could be obtained and be accurately controlled. It has been shown that the droplets are frozen within the transit time of the apparatus such that ice particles are present after the quadrupole stages and finally detected. The demonstrated correspondence between particle mass and specific quadrupole potentials in this device allows preparation of beams of single particles with a repetition rate between 0.1 and 1 Hz with various diameter distributions from 50 to 1000 nm at 30-250 eV of kinetic energy per charge. This corresponds to velocities and particle masses quickly available between 600 m/s (80 nm) and 50 m/s (900 nm) and particle charge numbers (positive) between 103 and 104[e], depending upon size.

5.
Anal Chem ; 95(7): 3621-3628, 2023 Feb 21.
Article in English | MEDLINE | ID: mdl-36753610

ABSTRACT

The coupling of an Orbitrap-based mass analyzer to the laser-induced liquid beam ion desorption (LILBID) technique has been investigated, with the aim to reproduce the mass spectra recorded by Cassini's Cosmic Dust Analyzer (CDA) in the vicinity of Saturn's icy moon Enceladus. LILBID setups are usually coupled with time-of-flight (TOF) mass analyzers, with a limited mass resolution (∼800 m/Δm). Thanks to the Orbitrap technology, we developed a unique analytical setup that is able to simulate hypervelocity ice grains' impact in the laboratory (at speeds in the range of 15-18 km/s) with an unprecedented high mass resolution of up to 150 000 m/Δm (at m/z 19 for a 500 ms signal duration). The results will be implemented in the LILBID database and will be useful for the calibration and future data interpretation of the Europa Clipper's SUrface Dust Analyzer (SUDA), which will characterize the habitability of Jupiter's icy moon Europa.

6.
Angew Chem Int Ed Engl ; 60(47): 24910-24914, 2021 Nov 15.
Article in English | MEDLINE | ID: mdl-34523217

ABSTRACT

While reactions between ions and neutral molecules in the gas phase have been studied extensively, reactions between molecular ions of same polarity remain relatively unexplored. Herein we show that reactions between fragment ions generated in the gas phase and molecular ions of the same polarity are possible by soft-landing of both reagents on surfaces. The reactive [B12 I11 ]1- anion was deposited on a surface layer built up by landing the generally unreactive [B12 I12 ]2- . Ex-situ analysis of the generated material shows that [B24 I23 ]3- was formed. A computational study shows that the product is metastable in the gas phase, but a charge-balanced environment of a grounded surface may stabilize the triply charged product, as suggested by model calculations. This opens new opportunities for the generation of highly charged clusters using unconventional building blocks from the gas phase.

7.
Anal Bioanal Chem ; 413(6): 1561-1570, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33479818

ABSTRACT

By the on-chip integration of a droplet generator in front of an emitter tip, droplets of non-polar solvents are generated in a free jet of an aqueous matrix. When an IR laser irradiates this free liquid jet consisting of water as the continuous phase and the non-polar solvent as the dispersed droplet phase, the solutes in the droplets are ionized. This ionization at atmospheric pressure enables the mass spectrometric analysis of non-polar compounds with the aid of a surrounding aqueous matrix that absorbs IR light. This works both for non-polar solvents such as n-heptane and for water non-miscible solvents like chloroform. In a proof of concept study, this approach is applied to monitor a photooxidation of N-phenyl-1,2,3,4-tetrahydroisoquinoline. By using water as an infrared absorbing matrix, analytes, dissolved in non-polar solvents from reactions carried out on a microchip, can be desorbed and ionized for investigation by mass spectrometry.

8.
Anal Chem ; 81(1): 443-52, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-19125446

ABSTRACT

A new atmospheric pressure (AP)-MALDI-type interface has been developed based on a free liquid (FL) microbeam/microdroplets and a mid-infrared optical parametric oscillator (mid-IR OPO). The device is integrated into a standard on-line nanoESI interface. The generation of molecular ions in the gas phase is believed to be the result of a fast (explosive) laser-induced evaporative dispersion(not desorption) of the microbeam into statistically charged nanodroplets. Only the lowest charge states appear insignificant abundance in this type of experiment. Mass spectra of some common peptides have been acquired in positive ion mode, and the limit-of-detection of this first prototype (liquid microbeam setup) was evaluated to be 17 fmol per second. To improve the duty cycle and to reduce the sample consumption, a droplet-on-demand system was implemented (generating 100 pL droplets).With this setup, about 20 attomole of bradykinin were sufficient to achieve a signal-to-noise ratio better than five.This setup can be operated at flow rates down to 100 nL/min and represents a liquid MALDI alternative to the nanoESI. Our particular interest was the application of the developed ion source for on-line coupling of liquid chromatography with mass spectrometry. The flow rates(>100 microL/min), required for stable operation of the ion source in continuous liquid microbeam mode, matches perfectly the flow rate range of micro HPLC. Therefore, online LC/MS experiments have been realized, employing a microbore C18 reversed-phase column to separate an artificial peptide mixture and tryptic peptides of bovine serum albumin (performing a peptide mass fingerprint). In the latter case, sequence coverage of more than 90%has been achieved.


Subject(s)
Chromatography, High Pressure Liquid/methods , Peptides/analysis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Atmospheric Pressure , Bradykinin/chemistry , Chromatography, High Pressure Liquid/instrumentation , Infrared Rays , Nanotechnology/instrumentation , Nanotechnology/methods , Peptides/chemistry , Serum Albumin, Bovine/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
9.
Phys Chem Chem Phys ; 9(26): 3335-60, 2007 Jul 14.
Article in English | MEDLINE | ID: mdl-17664960

ABSTRACT

Applications, features, and mechanistic details of laser assisted liquid phase dispersion mass spectrometry are highlighted and discussed. It has been used in the past to directly isolate charged molecular aggregates from the liquid phase and to determine their molecular weight employing sensitive time-of-flight mass spectrometry. The liquid matrix in this MALDI (matrix assisted laser desorption and ionization) type approach consists of a 10 microm diameter free liquid filament in vacuum (or a free droplet) which is excited with a focused infrared laser pulse tuned to match the absorption frequency of the OH-stretch vibration of bulk water near 2.8 microm. Due to these features we will refer to the approach as free liquid matrix assisted laser dispersion of ions or ionic aggregates (IR-FL-MALDI), although also LILBID ("laser induced liquid beam (bead) desorption and ionization") has been proposed early as a descriptive acronym for the technique and may be used alternatively. Low-charge-state macromolecular adducts are isolated in the gas phase from solution via a yet poorly characterized mechanism which sensitively depends upon the laser intensity and wavelength, and after the gentle liquid-to-vacuum transfer the aggregates are analyzed via time-of-flight (TOF) mass spectrometry (MS). Possible mechanisms for the isolation and charging of biomolecules directly from liquid solution are discussed in the present contribution. Recent technical advances such as minimizing the sample consumption, strategies for high throughput mass spectrometry, and coupling of liquid beam MS with HPLC will be highlighted as well. An interesting feature of IR-FL-MALDI is what we call the linear response, i.e., a surprising linearity of the gas phase mass signal on the solution concentration over many orders of magnitude for a large number of biomolecular systems as well as ions. Due to these features the approach may be regarded as a true solution probing spectroscopy, which enables elegant biokinetic studies. Several experiments in which time resolved IR-FL-MALDI-MS has recently been employed successfully are given. A particular highlight is the possibility to quantitatively detect oxidation states in solution, which clearly distinguishes the present approach from other established MS source concepts. Due to the good matrix tolerance also proteins in complex mixtures can be monitored quantitatively.


Subject(s)
Infrared Rays , Lasers , Macromolecular Substances/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Water/chemistry , Chromatography, High Pressure Liquid , Hemoglobins/chemistry , Ions/chemistry , Kinetics , Models, Biological , Phase Transition , Protein Folding , Proteins/chemistry
SELECTION OF CITATIONS