Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Haptics ; 17(1): 45-51, 2024.
Article in English | MEDLINE | ID: mdl-38252577

ABSTRACT

Wearable devices increasingly incorporate vibrotactile feedback notifications to users, which are limited by the frequency-dependent response characteristics of the low-cost actuators that they employ. To increase the range and type of information that can be conveyed to users via vibration feedback, it is crucial to understand user perception of vibration cue intensity across the narrow range of frequencies that these actuators operate. In this paper, we quantify user perception of vibration cues conveyed via a linear resonant actuator embedded in a bracelet interface using two psychophysical experiments. We also experimentally determine the frequency response characteristics of the wearable device. We then compare user perceived intensity of vibration cues delivered by the bracelet when the cues undergo frequency-specific amplitude modulation based on user perception compared to modulation based on the experimental or manufacturer-reported characterization of the actuator dynamic response. For applications in which designers rely on user perception of cue amplitudes across frequencies to be equivalent, it is recommended that a perceptual calibration experiment be conducted to determine appropriate modulation factors. For applications in which only relative perceived amplitudes are important, basing amplitude modulation factors on manufacturer data or experimentally determined dynamic response characteristics of the wearable device should be sufficient.


Subject(s)
Touch Perception , Humans , Touch Perception/physiology , Touch/physiology , Cues , Physical Stimulation , Feedback, Sensory , Vibration
2.
Small ; 13(12)2017 03.
Article in English | MEDLINE | ID: mdl-28090735

ABSTRACT

A clinically relevant magneto-optical technique (fd-FRS, frequency-domain Faraday rotation spectroscopy) for characterizing proteins using antibody-functionalized magnetic nanoparticles (MNPs) is demonstrated. This technique distinguishes between the Faraday rotation of the solvent, iron oxide core, and functionalization layers of polyethylene glycol polymers (spacer) and model antibody-antigen complexes (anti-BSA/BSA, bovine serum albumin). A detection sensitivity of ≈10 pg mL-1 and broad detection range of 10 pg mL-1 ≲ cBSA ≲ 100 µg mL-1 are observed. Combining this technique with predictive analyte binding models quantifies (within an order of magnitude) the number of active binding sites on functionalized MNPs. Comparative enzyme-linked immunosorbent assay (ELISA) studies are conducted, reproducing the manufacturer advertised BSA ELISA detection limits from 1 ng mL-1 ≲ cBSA ≲ 500 ng mL-1 . In addition to the increased sensitivity, broader detection range, and similar specificity, fd-FRS can be conducted in less than ≈30 min, compared to ≈4 h with ELISA. Thus, fd-FRS is shown to be a sensitive optical technique with potential to become an efficient diagnostic in the chemical and biomolecular sciences.


Subject(s)
High-Throughput Screening Assays/methods , Rotation , Serum Albumin, Bovine/analysis , Spectrum Analysis , Animals , Antibodies/chemistry , Cattle , Magnetite Nanoparticles/chemistry , Magnetite Nanoparticles/ultrastructure , Reproducibility of Results , Serum Albumin, Bovine/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...